Browse > Article
http://dx.doi.org/10.5478/MSL.2017.9.1.30

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method  

Lee, Jaeick (Analytical Science and Technology Laboratory, Doping Control Center, Korea Institute of Science and Technology)
Lee, Seunghwa (Analytical Science and Technology Laboratory, Doping Control Center, Korea Institute of Science and Technology)
Kim, Byungjoo (Analytical Chemistry Center, Division of Metrology for Quality Life, Korea Research Institute of Standards and Science)
Lee, Joonhee (Analytical Chemistry Center, Division of Metrology for Quality Life, Korea Research Institute of Standards and Science)
Kwon, Oh-Seung (Doping Control Center, Korea Institute of Science and Technology)
Cha, Eunju (Analytical Science and Technology Laboratory, Doping Control Center, Korea Institute of Science and Technology)
Publication Information
Mass Spectrometry Letters / v.9, no.1, 2018 , pp. 30-36 More about this Journal
Abstract
A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.
Keywords
Amino acid; mixed-mode chromatography; quantitation; serum; LC-ESI/MS/MS;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Food and Drug Administration (2001), Guidance for industry: Bioanalytical Method Validation. https://www.fda.gov/downloads/Drugs/Guidance/ucm070107.pdf.
2 Qu, J.; Wang, Y.; Luo, G.; Wu, Z.; Yang, C. Anal. Chem. 2002, 74, 2034.   DOI
3 Wu, G. Amino acids. 2009, 37, 1.
4 Thiele, B.; Stein, N.; Oldiges, M.; Hofmann, D. Methods. Mol. Biol. 2012, 828, 317.
5 Thiele, B.; Fullner, K.; Stein, N.; Oldiges, M.; Kuhn, A. J.; Hofmann, D. Anal. Bioanal. Chem. 2008, 391, 2663.   DOI
6 Armstrong, M.; Jonscher, K.; Reisdorph, N. A. Rapid Commun. Mass Spectrom. 2007, 21, 2717.   DOI
7 Le, A.; Ng, A.; Kwan, T.; Cusmano-Ozog, K.; Cowan, T. M. J. Chromatogr. B 2014, 944, 166.   DOI
8 Choi, M. S.; Rehman, S. U.; Kim, I. S.; Park, H. J.; Song, M. Y.; Yoo, H. H. J. Pharm. Biomed. Anal. 2017, 145, 5.