• Title/Summary/Keyword: sample recovery

Search Result 702, Processing Time 0.032 seconds

Window based Symbol Timing Recovery (윈도우 기반 심벌 타이밍 복원)

  • Lee, Chul-Soo;Jang, Seung-Hyun;Jung, Eui-Suk;Kim, Byoung-Whi
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.487-489
    • /
    • 2005
  • This paper proposes a symbol timing recovery method that is simple in structure and can provide high speed symbol synchronization. Transmitter and receiver are not synchronized in communication systems using digital modulation. Receiver should search the timing variation of transmitter continuously. The proposed timing recovery method searches sample position by comparing previous sample value with next sample value. This method can be applied to digital and optical transceivers with high data rate.

  • PDF

Studies on the Physical Properties of Twisted Yam Woven Fabrics by High Functional Covering Machine and Compound Twister (고성능 커버링기 및 복합연사기를 이용한 연사직물의 물성분석 연구)

  • Jun, Byung Ik;Song, Min Kyu;Choi, Jae Woo
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.227-233
    • /
    • 2000
  • The purpose of this study was to develop the High Functional Covering machine and the Compound Twister to produce the high value added textile goods and to meet the consumer's needs. For the study, 8 yarns and 12 fabrics were made with two developed machines and the tensile characteristics of the samples were tested and analysed. The result indicated that the sample fabrics kept their elongation regardless of buffering process. Elongation of the sample yarns was higher than those of yarns made with a traditional covering method. Elastic recovery of the sample fabrics was more effected by the recovery rate than by the number of extension and the characteristics of the sample yarns and fabrics were comparable to the yarns and fabrics made with a traditional covering method in terms of the position of Spandex yarns in their yarn structure and buffering effect.

  • PDF

The Physical Properties of Filling Batt Using Polyester Yarn (Polyester사를 이용한 충전용 솜사의 물성)

  • Park, Myung-Soo
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.347-350
    • /
    • 2007
  • To analyse basic properties for making packing batt according to doubling condition, packing batt yarn, of $300^D$, $900^D$, $3600^D$ made from DTY yarn $150^D$/48 were produced from KTDI. The results are as follows: The birefringence of the sample yarn increased with increasing the annealing temperature and denier. The initial modulus of the sample yarn decreased with increasing the annealing temperature and denier. The higher than annealing temperature of $160^{\circ}C$, initial modulus of the sample are equilibrated. The strain recovery ratio of samples decreased with increasing the annealing temperature and denier. The lower than annealing temperature of $140^{\circ}C$, strain recovery ratio of the sample are decreased Where the $900^D$, $3600^D$ yarns are at $100^{\circ}C$ the specific bending rigidity value obtained is 0.65kgf/d but the twisted yarn (3,600) obtained 0.006 ($gfcm^2/tex^2$). However, where the heat temperature is $160^{\circ}C$, specific bending rigidity value obtained 0.003($gfcm^2/tex^2$).

Comparison of Analytical Methods for α-Quartz by FTIR and XRD (FTIR과 XRD를 이용한 α-Quartz 분석법 비교)

  • Kim, Boo-Wook;Lee, Jong-Seong;Choi, Byung-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.130-142
    • /
    • 2009
  • This study compared FTIR with XRD method for the analysis of quartz by % recovery, coefficient of variation (CV) and influence of the interference. the results were as the following. 1. In FTIR method, the coefficient of determination ($r^2$) was 0.9998 in a calibration curve of $695\;cm^{-1}$, and the limit of detection was $4.9{\mu}g/sample$. 2. The highest recovery was $799\;cm^{-1}$ (98.2%). 3. The CVpooled of the FTIR method was approximately 10% in three wave numbers. 4. The analysis of qualitative and quantitative for quartz is difficult with mixed cristobalite and iron oxide. 5. In XRD method with rotating sample holder and LynxEye detector, the coefficient of determination was 0.9996 in a calibration curve, and the limit of detection was $5.9{\mu}g/sample$. 6. The recovery and CV pooled were 104.3%, and 11 %, respectively. 7. In muffle furnace ashing, the quartz weight decreased to 34% when the maximum weight of the iron oxide was more than eight times. In conclusion, the accuracy (% recovery) and precision (CV) of FTIR and XRD method for analyzing $\alpha$-quartz were similar. FTIR method was a disadvantage for sample matrix because it indicates possibility of interference. However, XRD method distinguished specific crystalline forms of silica, and the majority of silicate minerals. In addition, XRD method recommend filter dissolution to pretreatment method.

An Empirical Study of the Recovery Experiment in Clinical Chemistry (임상화학검사실에서 회수율 실험의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.184-188
    • /
    • 2006
  • The purpose of the recovery experiment in clinical chemistry is performed to estimate proportional systematic error. We must know all measurements have some error margin in measuring analytical performance. Proportional systematic error is the type of error whose magnitude increases as the concentration of analyte increases. This error is often caused by a substance in the sample matrix that reacts with the sought for analyte and therefore competes with the analytical reagent. Recovery experiments, therefore, are used rather selectively and do not have a high priority when another analytical method is available for comparison purposes. They may still be useful to help understand the nature of any bias revealed in the comparison of kit experiments. Recovery should be expressed as a percentage because the experimental objective is to estimate proportional systematic error, which is a percentage type of error. Good recovery is 100.0%. The difference between 100 and the observed recovery(in percent) is the proportional systematic error. We calculated the amount of analyte added by multiplying the concentration of the analyte added solution by the dilution factor(mL standard)/(mL standard + mL specimen) and took the difference between the sample with addition and the sample with dilution. When making judgments on method performance, the observed that the errors should be compared to the defined allowable error. The average recovery needs to be converted to proportional error(100%/Recovery) and then compared to an analytical quality requirement expressed in percent. The results of recovery experiments were total protein(101.4%), albumin(97.4%), total bilirubin(104%), alkaline phosphatase(89.1%), aspartate aminotransferase(102.8), alanine aminotransferase(103.2), gamma glutamyl transpeptidase(97.6%), creatine kinase(105.4%), lactate dehydrogenase(95.9%), creatinine(103.1%), blood urea nitrogen(102.9%), uric acid(106.4%), total cholesterol(108.5), triglycerides(89.6%), glucose(93%), amylase(109.8), calcium(102.8), inorganic phosphorus(106.3%). We then compared the observed error to the amount of error allowable for the test. There were no items beyond the CLIA criterion for acceptable performance.

  • PDF

Optimization of Solid Phase Extraction Method for Quantitative Analysis of Perfluorooctanoic Acid in Serum using Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Hyun-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.30-33
    • /
    • 2014
  • A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF

Development of Triboelectrostatic Separation Technique for Recovery of Nylon from Radiator of End-of-Life Vehicle (폐자동차(廢自動車) 라디에이터로부터 Nylon 회수(回收)를 위한 마찰하전정전선별(摩擦荷電靜電選別) 기술개발(技術開發))

  • Baek, Sang-Ho;Jeon, Ho-Seok;Kim, Su-Gang;Lee, Kwang-Hoon
    • Resources Recycling
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • The study on the recovery of Nylon from a radiator of End-of-Life Vehicle was conducted by using triboelectrostatic separation technique. For the effective separation of the sample(Nylon, PP glass), charge polarity and amount of each sample with various charging materials have been investigated by faraday cage. And then, charging material was selected as carrying out basic separation experiments with materials that can be possible to polarize samples. Finally, the continuos type triboelectrostatic separator was developed with selected charging material and the recovery possibility of the sample was confirmed as carrying out various separation experiments.

Study of Crease Resistant Finish on Hemp Fabrics(Andongpo) (대마직물(안동포)의 방추가공에 관한 연구)

  • Choi, Hee;Kim, Ryong;Hong, Sung-Hak
    • Fashion & Textile Research Journal
    • /
    • v.6 no.2
    • /
    • pp.229-233
    • /
    • 2004
  • Andongpo, 100% Korean hemp fabric was treated with the glyoxale resin type finishing agent and/or the soluble urethane type finishing agent to determine the optimum process condition of the crease resistant finish and the crease recovery of treated sample fabrics was evaluated for the study. The treatment conditions for the study were 6 conditions, such as, A-1~A-6, in which A-1 was the condition of treatment glyoxale resin type finishing agent only and A-2~A-6 were the condition of treatment both glyoxale resin type finishing agent and soluble urethane type finishing agent. Among the 6 conditions, the crease recovery of the sample treated with A-4 condition was $148^{\circ}$(angle of recovery method) and grade 3.2(appearance method) and so, these samples showed the excellent crease recovery. From the result, 15g/l of the catalyst conc., 50g/l of the glyoxale resin type finishing agent cone., and 40g/l of the softner were the optimum treatment condition for the crease resistant finish of the andongpo.

A Comparative Study on Factor Recovery of Principal Component Analysis and Common Factor Analysis (주성분분석과 공통요인분석에 대한 비교연구: 요인구조 복원 관점에서)

  • Jung, Sunho;Seo, Sangyun
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.933-942
    • /
    • 2013
  • Common factor analysis and principal component analysis represent two technically distinctive approaches to exploratory factor analysis. Much of the psychometric literature recommends the use of common factor analysis instead of principal component analysis. Nonetheless, factor analysts use principal component analysis more frequently because they believe that principal component analysis could yield (relatively) less accurate estimates of factor loadings compared to common factor analysis but most often produce similar pattern of factor loadings, leading to essentially the same factor interpretations. A simulation study is conducted to evaluate the relative performance of these two approaches in terms of factor pattern recovery under different experimental conditions of sample size, overdetermination, and communality.The results show that principal component analysis performs better in factor recovery with small sample sizes (below 200). It was further shown that this tendency is more prominent when there are a small number of variables per factor. The present results are of practical use for factor analysts in the field of marketing and the social sciences.