• Title/Summary/Keyword: sample collection lab

Search Result 12, Processing Time 0.039 seconds

Fabrication and Application of Micro Polymer Chip Platform for Rare Cell Sample Preparation (희귀 세포 샘플 준비를 위한 마이크로 폴리머 칩 플랫폼 제작 및 활용)

  • Park, Taehyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.217-222
    • /
    • 2018
  • In this paper, a new micro polymer chip platform and protocol were developed for rare cell sample preparation. The proposed platform and protocol overcome the current limitation of the dilution method which is based on statistics and the FACS method which expensive and requires fluorescence staining. It allows collecting exact number of target cells simply and selectively because the cells are visually confirmed during the collecting process. The collected cells can be transported or spiked into a desired locations, such as a microchamber, without cell loss. This research may applicable not only to a rare cell sample preparation for Lab on a Chip cancer diagnosis, but also to a single/double/multiple cell sample preparation for a cell analysis field. To verify this platform and protocol, five human breast cancer cells (MCF-7) were collected and transported into a hemocytometer chamber.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • Lee, Jeong-Heon;Jeong, Da-Sol;Nam, Yeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Color Changes of Natural Dyed Korean Paper(Hanji) by Repellents (방충·방균제로 인한 천연염색 한지의 색변화)

  • Roh, Hyunsook;Lee, Sungeun
    • Conservation Science in Museum
    • /
    • v.6
    • /
    • pp.39-46
    • /
    • 2005
  • The National Museum of Korea has a collection of various materials. In particular, items made from organic materials such as wood, paper, and leather are vulnerable to the influence of insects and germs, requiring fumigation as well as pesticides and bactericides. The influence of pesticides and bactericides on the change in dyed paper was examined by applying the oddy test used to confirm the toxicity of various materials used in museums. Results revealed that the products of B and H companies had the least influence on the change in dyed paper. On the other hand, the result of the examination of cochineal and curcuma dyed paper revealed a significant change in the control group compared to the one exposed together with dyed paper, probably because of humidity rather than the sample.

Complete genome sequence of Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) isolated from healthy Korean feces (건강한 한국인 분변으로부터 분리된 Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) 균주의 유전체 염기서열 초안)

  • Kim, Ji-Sun;Kang, Se Won;Han, Kook-Il;Lee, Keun Chul;Eom, Mi Kyung;Suh, Min Kuk;Kim, Han Sol;Lee, Ju Huck;Park, Seung-Hwan;Park, Jam-Eon;Oh, Byeong Seob;Yu, Seung Yeob;Choi, Seung-Hyeon;Ryu, Seoung Woo;Lee, Dong Ho;Yoon, Hyuk;Kim, Byung-Yong;Lee, Je Hee;Lee, Jung-Sook
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.289-292
    • /
    • 2019
  • Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) belonging to the class Clostridia in phylum Firmicutes, was isolated from a stool sample of a healthy Korean. Herein, we report the complete genome sequence of strain KGMB03038 analyzed using the PacBio Sequel platform. The genome comprises of 3,334,474 bp with G + C content of 47.8%, which includes 3,099 predicted protein-coding genes, 12 ribosomal RNAs, 54 transfer RNAs, and 4 ncRNAs. Genome analysis revealed that strain KGMB03038 possesses a number of genes involved in hydrolysis of carbohydrates, including mono-, di-, and oligo-saccharides, and biosynthesis of various amino acids.

The Effect of Hemolysis sample on the Result of Nuclear Medicine Blood test (용혈검체가 핵의학 검체검사 결과에 미치는 영향)

  • Kim, Jin-Tae;Lee, Jong-Pil;Lee, Soo-Bin;Kim, Dong-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.41-43
    • /
    • 2021
  • Purpose In nuclear medicine blood tests, hemolysis samples are considered as inappropriate sample and are recommended not to be used for blood test. So, the lab are required to collect the blood again in the blood collection room However, The effect of hemolyzed samples on radioimmunoassay has not studied yet. This study was designed to evaluate effects of hemolysis on radioimmunoassay. Materials and Methods The kit manuals of 23 test items were reviewed to confirm whether hemolyzed samples were used. The subjects were 19 general applicants(male : 9, female : 13) and the samples were collected by each two SST tubes, one tube was obtained by centrifugation normally, and the other was obtained hemolyzed sample by centrifugation after external shock. It has been known that highly hemolyzed samples can affect the test results, so the test was performed using the severe hemolyzed sample. The test was performed for each test item using 23 normal serum and hemolysis serum, and SPSS19 program was used for statistical comparison of the test result. Results There was no significant difference between normal serum and hemolysis serum in 21 of 23 test items, but the results of insulin and C-peptide were significantly different(P<0.05). Conclusion It has been known that hemolysis in blood samples can affect the results of biochemical and hematological test, However, hemolysis effect is relatively low. Similarly, this study showed that hemolysis had not much effect on most of immunological radioimmunoassay except for some tests. Therefore, it is thought that the demand for re-collection due to hemolysis will be reduced in the laboratory, which will improve the work process of the laboratory.

Measurement uncertainty evaluation in FaroArm-machine using the bootstrap method

  • Horinov, Sherzod;Shaymardanov, Khurshid;Tadjiyev, Zafar
    • Journal of Multimedia Information System
    • /
    • v.2 no.3
    • /
    • pp.255-262
    • /
    • 2015
  • The modern manufacturing systems and technologies produce products that are more accurate day by day. This can be reached mainly by improvement the manufacturing process with at the same time restricting more and more the quality specifications and reducing the uncertainty in part. The main objective an industry becomes to lower the part's variability, since the less variability - the better is product. One of the part of this task is measuring the object's uncertainty. The main purpose of this study is to understand the application of bootstrap method for uncertainty evaluation. Bootstrap method is a collection of sample re-use techniques designed to estimate standard errors and confidence intervals. In the case study a surface of an automobile engine block - (Top view side) is measured by Coordinate Measuring Machine (CMM) and analyzed for uncertainty using Geometric Least Squares in complex with bootstrap method. The designed experiment is composed by three similar measurements (the same features in unique reference system), but with different points (5, 10, 20) concentration at each level. Then each cloud of points was independently analyzed by means of non-linear Least Squares, after estimated results have been reported. A MatLAB software tool used to generate new samples using bootstrap function. The results of the designed experiment are summarized and show that the bootstrap method provides the possibility to evaluate the uncertainty without repeating the Coordinate Measuring Machine (CMM) measurements many times, i.e. potentially can reduce the measuring time.

A Study on the Composting Process of Food Waste by Seeding the Isolated Effective Microorganism (음식폐기물 퇴비화에서 유효 미생물 분리 및 첨가에 관한 연구)

  • 이장훈;정준오;박승호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • Although microorganisms play an important role in composting process, researches on the effective microorganism (EM) in composting process are rarely reported. In this study, three stages of work performed 1) investigation of composting facility 2) sample collection and isolation of the EM 3) lab-scale composting by seeding the isolated EM. For this, purpose, physical, chemical, and biological characteristics, such as temperature, moisture content, organic matter, pH population of microorganism, etc., were investigated during the process and the results were compared with those of a control(non-seeded). In the composting facility, the most active degradation of food waste was suppsed to occur in 10-11th day of composting by observing the temperature and CO2 emission. The population of bacterial and fungi was highest in thermophilic stage. Meanwhile that of actinomycetes and yeast was relatively uniform during the process. In the lab-scale test, the thermophilic stage was maintained longer(more than 9 days in 17 days of experiment) in the seeded which was favored for the high reduction of organic matter and moisture. Reduction rates of lipids and salinity were also increased in the seeded. It confirmed these results that the population of microorganisms in the seeded was observed higher in several orders than the control. However, pH of the seeded was maintained as low as about 4.5 throughout the experiment except the final period of the process. Meanwhile, pH of the control rose in the early stage of the experiment. This was probably due that the seeded microorganisms collected from the composting facility was adapted to the low pH environment.

  • PDF

Serological Detection of Borrelia burgdorferi among Horses in Korea

  • Lee, Seung-Hun;Yun, Sun-Hee;Choi, Eunsang;Park, Yong-Soo;Lee, Sang-Eun;Cho, Gil-Jae;Kwon, Oh-Deog;Kwak, Dongmi
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.1
    • /
    • pp.97-101
    • /
    • 2016
  • Lyme disease is a tick-borne zoonotic infectious disease caused by Borrelia burgdorferi. The present study assessed the infection status of B. burgdorferi among horses reared in Korea using ELISA and PCR. Between 2009 and 2013, blood samples were collected from 727 horses throughout Korea. Data for each animal including age, gender, breed, and region of sample collection were used for epidemiological analysis. Overall, 38 (5.2%; true prevalence: 5.5%) of 727 horses were seropositive by ELISA. There were statistically significant differences according to breed and region (P<0.001) whose differences might be attributed to the ecology of vector ticks and climate conditions. Using 2 nested PCR, none of the samples tested positive for B. burgdorferi. Thus, a positive ELISA result can indicate only that the tested horse was previously exposed to B. burgdorferi, with no certainty over the time of exposure. Since global warming is likely to increase the abundance of ticks in Korea, continuous monitoring of tick-borne diseases in Korean horses is needed.

Determination of Mequitazine in Human Plasma by Gas-Chro-matography/Mass Spectrometry with Ion-Trap Detector and Its Pharmacokinetics after Oral Administration to Volunteers

  • Kwon Oh-Seung;Kim Hye-Jung;Pyo Heesoo;Chung Suk-Jae;Chung Youn Bok
    • Archives of Pharmacal Research
    • /
    • v.28 no.10
    • /
    • pp.1190-1195
    • /
    • 2005
  • The objective of this study was to develop an assay for mequitazine (MQZ) for the study of the bioavailability of the drug in human subjects. Using one mL of human plasma, the pH of the sample was adjusted and MQZ in the aqueous phase extracted with hexane; the organic layer was then evaporated to dryness, reconstituted and an aliquot introduced to a gas chromatograph/mass spectrometer (GC/MS) system with ion-trap detector. Inter- and intra-day precision of the assay were less than 15.1 and $17.7{\%}$, respectively; Inter- and intra-day accuracy were less than 8.91 and $18.6{\%}$, respectively. The limit of quantification for the current assay was set at 1 ng/mL. To determine whether the current assay is applicable in a pharmacokinetic study for MQZ in human, oral formulation containing 10 mg MQZ was administered to healthy male subjects and blood samples collected. The current assay was able to quantify MQZ levels in most of the samples. The maximum concentration ($C_{max}$ was 8.5 ng/mL, which was obtained at 10.1 h, with mean half-life of approximately 45.5 h. Under the current sampling protocol, the ratio of $AUC_{t{\rightarrow}last}$ to $AUC_{t{\rightarrow}{\infty}}$ was $934{\%}$, indicating that the blood collection time of 216 h is reasonable for MQZ. Therefore, these observations indicate that an assay for MQZ in human plasma is developed by using GC/MS with ion-trap detector and validated for the study of pharmacokinetics of single oral dose of 10 mg MQZ, and that the current study design for the bioavailability study is adequate for the drug.