지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험 (Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building)

  • 김진구;송영훈;권형오;허영
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

성인 머리모형 임팩터의 FE 모델 개발 (Development and Validation of FE Adult Headform Impactor for Pedestrian Protection)

  • 최지훈;박부창;김종선
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.64-69
    • /
    • 2012
  • Head injury is one of the most common cause of deaths in car-to-pedestrian collisions. To reduce the severity of such injuries, many international safety committees have performed headform impact test for pedestrian protection. In this paper, an adult headform impactor model is developed based on the finite element (FE) method and validated through the numerical simulation. The skin material of headform impactor is known as polyvinyl chloride skin (PVC) and its material was assumed as viscoelastic. The viscoelastic parameters of headform skin are identified by a series of trial and error methods. The new developed FE adult headform impactor is verified by the drop test and FE JARI adult headform impactor provided by Madymo program.

일부 농촌 지역의 간이 상수도와 Pump수의 수질에 관한 비교 연구조사 -춘성군 지역을 중심으로- (A Comparative study on drinking Water quality of simple piped Water supply Systems and water Pumps.)

  • 정문호;송금순
    • 한국환경보건학회지
    • /
    • 제9권1호
    • /
    • pp.77-84
    • /
    • 1983
  • A study was carried out to find drinking water qualities of 56 simple piped water supply systems and 37 water pumps in Chun Sung Conutry, Kang Won Province from 1st July to 30th August 1981. 1. The results of all kinds of water test are found to be safe at only one out of fifty six samples of simple piped water supply system at two out of thirty-seven samples of water pump and unsafe at the others. 2. In general Count of Bacteria test, twelve (21.4%) out of fifty six samples of the simple piped water are found to be safe for the legitimate standard of safty water, and five (13.5%) out of thirty=seven samples of pump water. 3. Escherichia coli group is negative at seven (12.5%) out of fifty-six samples of simple piped water, and eight (21.6%) out of thirty-seven samples of pump water. 4. The results of the physical and chemical examination of drinking water specimen are found to be safe at twelve out of fifty-six samples of simple piped water and at twenty-eight out of thirty-seven samples of pump water.

  • PDF

환경적 요인에 따른 비파괴 철근 탐사의 오차율에 관한 연구 (A Study on the Error Rate of Non-destructive Rebar Detection Under Different Environmental Factors)

  • 강범주;김영환;김영민;박경한;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.506-513
    • /
    • 2021
  • 철근콘크리트 구조물의 내구성 및 안전성은 콘크리트의 균열 및 강도와 더불어 철근의 배근상태나 콘크리트 피복 두께에 크게 의존한다. 콘크리트 내에 매립되어 있는 철근 정보를 정확히 파악하는 방법엔 국부 파괴법과 비파괴 철근 탐사 시험이 있다. 일반적으로 부재 손상을 최소화하기 위해 비파괴 철근 탐사 시험을 통해 파악하며, 비파괴 철근 탐사 시험에는 전자파레이더법, 전자기유도법, 방사선법 등이 있다. 콘크리트의 함수율과 온도는 콘크리트의 전기적 특성인 유전율에 영향을 미쳐 비파괴 철근 탐사 시험 결과에 간섭을 방생시킨다. 따라서 본연구에서는 콘크리트의 표면수율과 온도에 따라 전자파레이더법과 전자기유도법이 받는 영향을 분석하였다. 장비와 기술의 발달로 원리와 상관없이 24℃ 시험체에서는 평균 오차율이 5% 이하로 나타났으며 특히 전자기유도법의 경우 매우 높은 정확성을 갖는 것을 확인하였다. 전자파레이더법은 습윤상태보다 건조상태에서 상대적으로 오차율이 작은 특성을 나타내었으며, 고온에서는 다소 높은 오차율이 나타났다. 탐사 대상의 온도가 낮고 건조한 경우 전자파레이더법을 적용하고, 탐사 대상이 습윤상태이거나 고온에서는 전자기유도법을 사용하여 오차를 감소시킬 수 있음이 확인되었다.

Behavior of Laterally Damaged Prestressed Concrete Bridge Girders Repaired with CFRP Laminates Under Static and Fatigue Loading

  • ElSafty, Adel;Graeff, Matthew K.;Fallaha, Sam
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권1호
    • /
    • pp.43-59
    • /
    • 2014
  • Many bridges are subject to lateral damage for their girders due to impact by over-height vehicles collision. In this study, the optimum configurations of carbon fiber reinforced polymers (CFRP) laminates were investigated to repair the laterally damaged prestressed concrete (PS) bridge girders. Experimental and analytical investigations were conducted to study the flexural behavior of 13 half-scale AASHTO type II PS girders under both static and fatigue loading. Lateral impact damage due to vehicle collision was simulated by sawing through the concrete of the bottom flange and slicing through one of the prestressing strands. The damaged concrete was repaired and CFRP systems (longitudinal soffit laminates and evenly spaced transverse U-wraps) were applied to restore the original flexural capacity and mitigate debonding of soffit CFRP longitudinal laminates. In addition to the static load tests for ten girders, three more girders were tested under fatigue loading cycles to investigate the behavior under simulated traffic conditions. Measurements of the applied load, the deflection at five different locations, strains along the cross-section height at mid-span, and multiple strains longitudinally along the bottom soffit were recorded. The study investigated and recommended the proper CFRP repair design in terms of the CFRP longitudinal layers and U-wrapping spacing to obtain flexural capacity improvement and desired failure modes for the repaired girders. Test results showed that with proper detailing, CFRP systems can be designed to restore the lost flexural capacity, sustain the fatigue load cycles, and maintain the desired failure mode.

일반시설에서 사육되는 마우스의 품질향상을 위한 기초조사 연구 (Survey on environmental condition and health state of laboratory mouse in conventional facility)

  • 이흥식;성노현;김경진;김철규
    • 대한수의학회지
    • /
    • 제40권3호
    • /
    • pp.611-625
    • /
    • 2000
  • For the improvement of quality control of laboratory mouse, we investigated the environmental condition, histopathological findings and serological test using ELISA to mouse hepatitis virus(MHV), Mycoplasma pulmonis(MP), Clostridium piliforme(TZ) and Sendai virus (HVJ) of ICR, C57BL/6, CBA and C3H/He mice that were supplied from conventional laboratory animal facility. 1. The ammonia concentration of facility was below the recommended concentration, 15ppm, by the KNIH, and the room temperature($21{\sim}23^{\circ}C$) and relative humidity(40~60%) was optimum range recommend by the Ministry of Health and Welfare, respectively. 2. The incidence rate of inapparent disease was 86.6% and the major findings in the liver were vacuolar degeneration with nucleic pleomorphism. The lung was shown the thickening of alveolar wall and interstitial pneumonia with congestion. The kidney and spleen were observed the mild congestion and extramedullary hematopoiesis, respectively. 3. The positive reaction rates against MHV and MP in serological test was 97.9% and 37.5%, respectively but HVJ and TZ were negative. These results suggest that laboratory mice could be infected with MHV and MP under conventional environments. Therefore we recommend to select thoroughly inapparent infected mice and to convert conventional system into SPF facility as soon as possible.

  • PDF

압력카트리지를 이용한 볼타입 볼트 분리현상 연구 (A Study of Separartion Mechanism in Ball Type Bolt Used the Pressure Cartridge)

  • 이응조;구송회;장홍빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.293-296
    • /
    • 2008
  • 현재의 많은 유도무기들은 발사관에 장착되어 보관 및 이동되다가 필요시 발사된다. 발사관이란 유도탄 즉 미사일등이 외부환경에 노출되지 않도록 유도탄을 둘러싸고 있는 일종의 케이스이며 또한 유도탄 발사시 가이드 역할을 동시에 수행한다. 유도탄과 발사관을 연결하는 방법으로 흔히 사용되는 것으로 탄고정장치를 사용하는데 대표적인 파이로 부품이 폭발볼트이다. 폭발볼트는 화약의 폭발력에 의해 볼트몸체가 절개됨으로써 볼트에 의해 결합되고 있던 부분이 분리된다. 하지만 기존의 폭발볼트는 분리시 파편, 화염 및 pyro-shock이라는 악작용을 수반하므로 사용상 제한을 가지고 있다. 이와 같은 문제점을 해결하기 위하여 압력카트리지에서 발생하는 압력을 분리력으로 사용할 수 있는 분리장치 즉 볼타입 볼트를 개발하게 되었다. 본 연구에서는 볼타입볼트의 분리현상을 분석하여 분리볼트의 분리성능 안전율을 정량적으로 제시하였다.

  • PDF

산불진화대원용 안전장갑에 대한 성능평가 기준 연구 (A Study on Performance Evaluation Criteria for Safty Gloves for Forest Firefighting Crews)

  • 김해형;이선영;정재한;권춘근;안희영;홍승태
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.74-83
    • /
    • 2018
  • 산불진화대원의 안전 확보와 작업능률 향상을 위해 안전장갑에 대한 성능평가 기준을 개발하였다. 산불진화대원용 안전장갑에 대한 기준이 현재 국내에 없기 때문에 한국소방산업기술원(KFI)에서 운용중인 소방대원용 안전장갑에 대한 기준을 기초로 하여 연구를 시작하였다. 관계자 의견 수렴 및 외국 기준의 검토를 통하여 17개 시험항목 중 5개 시험항목을 제외하고 12개 시험항목을 선정하였다. 시료는 산불진화대원들이 사용하고 있는 2 종류의 일반 안전장갑과 하나의 소방대원용 장갑에 대해 KFI 기준을 적용하여 시험하고 그 결과를 비교하였다. 시험 결과 불에 약한 나일론이나 폴리우레탄 등의 재질은 산불진화대원용 안전장갑에 적합하지 않음을 확인하였다. KFI 기준과 ISO 16073, NFPA 1977, NFPA 1971 및 BS EN 659의 판정기준을 비교하여 우리나라 산불진화대원들의 작업 환경에 적합한 12개 시험항목과 판정기준들을 최종 선정하였다.

내분비계장애물질 대체소재의 안전성 (Safty of Alternatives for Endocirne Disrupting Substances)

  • 박찬진;김웅;계명찬
    • 환경생물
    • /
    • 제33권4호
    • /
    • pp.361-374
    • /
    • 2015
  • 내분비계장애물질 (endocrine disruptors)은 포유류에서 축적되어 내분비계를 교란하며, 특히 수정능, 초기발생 등에 악영향을 미치고 암을 유발할 수 있는 것으로 잘 알려져 있다. 이러한 내분비계장애물질은 그 내분비계 교란 효과에 대한 지식이 부족하여 페인트, 코팅, 세제, 플라스틱 등에 활발히 사용되어 왔다. 특히 가정에서 내분비계장애물질은 음식 용기, 물병, 세탁용 세제 등에 사용되어 인체에 쉽게 노출되었다. 이후 내분비계장애물질의 위험성을 인식하면서 세계 각국에서는 내분비계장애물질의 생산 및 사용을 규제하고 대체재를 발굴하기 시작하였다. 그러나 현재까지 보고된 대체재의 안전성 또한 불확실하며, 이들의 인체에 대한 악영향을 완전히 파악하지 못한 채 사용하고 있다. 최근 이러한 대체재들 중 기존의 내분비계장애물질과 구조적으로 유사하고 내분비계 교란 효과를 갖는 물질이 있음이 밝혀졌으며, 이에 본 소고에서는 기존에 알려진 대표적인 내분비계장애물질인 bisphenol-A, phthalates, nonylphenols 및 이들의 대체재가 인체에 미치는 영향을 파악하고, 나아가 일부 대체재들에 대한 in-silico 분석을 수행함으로써 현존하는 대체재의 안전성에 의문을 제기하고 바람직한 소재 발굴을 위한 가이드를 제시하고자 하였다.

도시ㆍ농촌 지역 어머니의 보육시설 질적 기준에 대한 인식 비교 (The Comparision of Mother′s Perception of the Importance of Selected Quality Criteria when Choosing a Day Care Center in Urban and Rural Community)

  • 박인전;안지연
    • 한국농촌생활과학회지
    • /
    • 제6권2호
    • /
    • pp.121-136
    • /
    • 1995
  • The purposes of this research are to find out the standards which mothers consider seriously when choosing a day care center and mother's perception for the quality criteria of day care center, and to estimate the differences of these according to region. The sample consisted of 568 mothers with children using day care center located at the city of Taegu and Dalsung Gun. Collected data were analyzed by frequency, Percentage, chi-square, t-test, chronbach's $\alpha$. The results are summerized as follows : 1. In mother's perception for the quality criteria of day care center, the mothers living in the large city perceived more importantly in staff qualifications, administration - evaluation, staff- parent/staff- child interaction, curriculum, staffing, physical environment nutrition, health and safty than mothers in rural community. 2. In the importance classified by domains of the quality criteria of day care center, there were statistically significant differences according to the variable of region in staff qualifications, staff-parent/staff-child interaction, curriculum, staffing, physical environment 3. Given the present situations (income, transportation, location of workplace, etc.), when mothers choose a day care center, generally, staff-parent/staff-child interaction was the most important factor. And according to region, the distance to workplace or home was the most important factor in the case of mothers living in the large city, on the other hand, staff-parent/staff-chad interaction was the most important factor in the case of mothers living in rural community when mothers choose an ideal day care center, generally staff-parent/staff-chad interaction was the most important selection standard, and there were not remarkable differences according to region.

  • PDF