• Title/Summary/Keyword: safety switch

Search Result 165, Processing Time 0.031 seconds

Development of the SIS Evaluation Method Based on Reliability Analysis (신뢰도 분석에 근거한 SIS 평가 방법론 개발)

  • Kim In-Won;Jin Sang-Hwa;Song Kwang Ho;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.66-73
    • /
    • 2002
  • In this study a new SIS evaluation method based on the reliability analysis has been developed. It evaluates the Safety Integrity Level (SIL) using the Fault Tree Analysis (FTA), and when the SIL falls short of the systems target level, through the reliability analysis and system retrofit, this method will satisfy the aimed SIL. A hazard evaluation was carried out on the 415V Diesel BUS to verify the SIL evaluation method based on the reliability analysis. The availability of the original 415V Diesel BUS was $99.40\%$, which comes under the category of SIL 2. After exchanging the diesel generator and the isolator switch using the developed evaluation method, the availability rose to $99.94\%$, SIL 3. By applying the method presented in this study, not only will it reduce the maintenance cost due to the prevention of accidents and reduction of loss, but also maximize the reliability of the system.

  • PDF

A Study of Robotic Risk Confrontation Administration on the Ship Fire (선박 화재시의 Robot을 이용한 Risk 대응 관리 연구)

  • Park, Dea-Woo;Park, Young-suk;Nam, Jae-Min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.276-279
    • /
    • 2009
  • Is introducing ship automation system for the safety of ship and work environment mend recently. Is endeavoring for sea safety and fire at sea prevention solidifying control of standard technology and safety supervision aspect in IMO but sea accident and ship fire are happening continuously. Because using Robot in artistic talent of ship in this treatise, studied that correspond to Risk and manage. Attach fire perception sensor for Robot's Risk confrontation, and because using infrared rays sensor, TOUCH SWITCH, sound perception sensor, gas perception sensor, light perception sensor that is threaded in Robot and is achieved, controlled Robot, and establish Low-High value the speed of sound output use and DC MOTOR and COM SEN of when indicate Risk confrontation to Robot and establish Robot's Risk confrontation administration action.

  • PDF

ZVT Series Capacitor Interleaved Buck Converter with High Step-Down Conversion Ratio

  • Chen, Zhangyong;Chen, Yong;Jiang, Wei;Yan, Tiesheng
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.846-857
    • /
    • 2019
  • Voltage step-down converters are very popular in distributed power systems, voltage regular modules, electric vehicles, etc. However, a high step-down voltage ratio is required in many applications to prevent the traditional buck converter from operating at extreme duty cycles. In this paper, a series capacitor interleaved buck converter with a soft switching technique is proposed. The DC voltage ratio of the proposed converter is half that of the traditional buck converter and the voltage stress across the one main switch and the diodes is reduced. Moreover, by paralleling the series connected auxiliary switch and the auxiliary inductor with the main inductor, zero voltage transition (ZVT) of the main switches can be obtained without increasing the voltage or current stress of the main power switches. In addition, zero current turned-on and zero current switching (ZCS) of the auxiliary switches can be achieved. Furthermore, owing to the presence of the auxiliary inductor, the turned-off rate of the output diodes can be limited and the reverse-recovery switching losses of the diodes can be reduced. Thus, the efficiency of the proposed converter can be improved. The DC voltage gain ratio, soft switching conditions and a design guideline for the critical parameters are given in this paper. A loss analysis of the proposed converter is shown to demonstrate its advantages over traditional converter topologies. Finally, experimental results obtained from a 100V/10V prototype are presented to verify the analysis of the proposed converter.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

A Study on the Safety System Modeling to Prevent Train Accident by Turn-out Failure (분기기 고장 시 열차사고방지를 위한 안전시스템 모델링)

  • Yoo, Kwang-Kiun;Rho, Sung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.724-730
    • /
    • 2011
  • A turnout serves to switch train from one line to another. The turnout consists of a Point which is switchs the rail to induce direction, and a Crossing which is cross over two line on the plane surface, and a Lead where is middle section in Point to Crossing. Point machine, consists of a turnout, is important facilities in railway signal, that is safety issue relates in derailment of the train. Recently, train delay and accident frequently occurred because of the turnout include in a point machine trouble of electrical and mechanical. So in order to prevent train accident the research is advanced, install of normal and reverse indication lamp in a point machine, development of adherence detector for sensing the status of adhesion between the stock rails and tongue rails etc. In this paper investigates the problem which is connected with a turnout trouble, include in a point machine, occurrence at the time of train accident, and then proposed to the safety system model in order to prevent the train accident in turnout.

  • PDF

A study on the Electrical Fire Hazard by using individual switch multiple-tap (개별스위치 멀티탭 사용에 의한 전기화재 위험성 연구)

  • Park, Kwang-Muk;Bang, Sun-Bae;Lee, Ki-Yeon;Seo, Gil-Oh;Jeong, Jong-ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1529-1530
    • /
    • 2015
  • 본 논문에서는 점점 증가하고 있는 전기적 요인에 의한 화재 중에서 최근 발생한 개별스위치 멀티탭 화재 사례를 분석하였으며 개별스위치의 반복동작실험과 과전류 인가 시 시간에 따른 개별스위치 멀티탭의 온도변화 특성을 관찰하고 개별 스위치 사용에 따른 전기화재 위험성을 분석하였다.

  • PDF

Direct Switch from Tiotropium to Indacaterol/Glycopyrronium in Chronic Obstructive Pulmonary Disease Patients in Korea

  • Lee, Sang Haak;Rhee, Chin Kook;Yoo, Kwangha;Park, Jeong Woong;Yong, Suk Joong;Kim, Jusang;Lee, Taehoon;Lim, Seong Yong;Lee, Ji-Hyun;Park, Hye Yun;Moon, Minyoung;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.2
    • /
    • pp.96-104
    • /
    • 2021
  • Background: Many chronic obstructive pulmonary disease (COPD) patients receiving monotherapy continue to experience symptoms, exacerbations and poor quality of life. This study aimed to assess the efficacy and safety of direct switch from once-daily tiotropium (TIO) 18 ㎍ to indacaterol/glycopyrronium (IND/GLY) 110/50 ㎍ once daily in COPD patients in Korea. Methods: This was a randomized, open-label, parallel group, 12-week trial in mild-to-moderate COPD patients who received TIO 18 ㎍ once daily for ≥12 weeks prior to study initiation. Patients aged ≥40 years, with predicted post-bronchodilator forced expiratory volume in 1 second (FEV1) ≥50%, post-bronchodilator FEV1/forced vital capacity <0.7 and smoking history of ≥10 pack-years were included. Eligible patients were randomized in a 1:1 ratio to either IND/GLY or TIO. The primary objective was to demonstrate superiority of IND/GLY over TIO in pre-dose trough FEV1 at week 12. Secondary endpoints included transition dyspnea index (TDI) focal score, COPD assessment test (CAT) total score, and rescue medication use following the 12-week treatment, and safety assessment. Results: Of the 442 patients screened, 379 were randomized and 347 completed the study. IND/GLY demonstrated superiority in pre-dose trough FEV1 versus TIO at week 12 (least squares mean treatment difference [Δ], 50 mL; p=0.013). Also, numerical improvements were observed with IND/GLY in the TDI focal score (Δ, 0.31), CAT total score (Δ, -0.81), and rescue medication use (Δ, -0.09 puffs/day). Both treatments were well tolerated by patients. Conclusion: A direct switch from TIO to IND/GLY provided improvements in lung function and other patient-reported outcomes with an acceptable safety profile in patients with mild-to-moderate airflow limitation.

A Study on safety against a fire of charging cable for mobile phone for vehicle (자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구)

  • Kwon, Jin-Wook;Choi, Kyu-Sik;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.