• Title/Summary/Keyword: safety standard and work method

Search Result 112, Processing Time 0.027 seconds

Experimental Study on Tensile Strength of Straight-Line Connection Using Sleeve for Indirect Method (간접활선용 압축 슬리브를 이용한 전선 직선접속에 대한 실험적 연구)

  • Kim, Sang-Bong;Kim, Kang-Sik;Oh, Gi-Dae;Song, Won-Keun;Keum, Ui-Yeon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.85-91
    • /
    • 2021
  • With the social atmosphere of respect for human life and the increasing interest in safety of field workers, research and development is underway in various ways to transform direct live method into indirect live method in the field of distribution. As part of this measure, it was necessary to convert electric pole and complex facilities work from machining power distribution to indirect live operation, and install a straight connecting sleeve that connects cut wires for by-pass method, but it failed to meet the tensile strength standard when constructing a sleeve constructed by direct method. In this paper, the design factors were derived based on the case of overseas similar sleeves and the tensile strength evaluation of each variable was performed, based on the analysis of these test results, the method for securing tensile strength of straight-line access sleeves for indirect running was presented.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Advanced Indentation Studies on the Effects of Hydrogen Attack on Tensile Property Degradation of Heat-Resistant Steel Heat-Affected Zones

  • Choi, Yeol;Jang, Jae-il;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeong-Tae
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.266-271
    • /
    • 2003
  • Safety diagnosis of various structural components and facilities is indispensable for preventing catastrophic failure of material by time-dependent and environment accelerating degradation. Also, this diagnosis of operating components should be done periodically for safe maintenance and economical repair. However, conventional standard methods for mechanical properties have the problems of bulky specimen, destructive procedure and complex procedure of specimen sampling. So, a non-destructive and simple mechanical testing method using small specimen is needed. Therefore, an advanced indentation technique was developed as a potential method for non-destructive testing of in-field structures. This technique measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation such as yield strength, tensile strength and work-hardening index. In this paper, we characterized the tensile properties including yield and tensile strengths of the V-modified Cr-Mo steels in petro-chemical and thermo-electrical plants. And also, the effects of hydrogen-assisted degradation of the V-modified Cr-Mo steels were analyzed in terms of work-hardening index and yield ratio.

Load Redistribution of Prestressed Concrete Girder Bridges during the Bearing Replacement

  • Park, Sun-Kyu;Kim, Hyeong-Yeol;Kim, Jung-Hyuk
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.141-151
    • /
    • 1999
  • In the replacement of bearing system of bridges, the jacking work to secure work spaces may cause damage of the superstructure, hence the behavior of superstructure by the jacking force must be considered. Especially, in prestressed concrete I-type girder bridges, considering the stress concentration at the girder and the load redistribution of superstructure, the allowable jacking force and jacking sequence have to be determined. In this study, an analytical method is proposed to calculate the jacking force and overall jacking sequence for the replacement of bearing system without any damage to the superstructure. The stress concentration at the girder and load redistribution of the deck due to jacking force are considered to compute the allowable jacking force for each girder and overall jacking sequence for girders in the deck. Using the solution algorithm developed in this study, the optimum jacking sequence and required jacking force for the prestressed concrete I-type gilder bridge having the standard sections are calculated.

  • PDF

A Study on Improving National Competency Standard (국가직무능력표준(NCS: National Competency Standard)의 개선방안에 관한 연구)

  • Park, Jae-Hyeon;Choi, Sung-Hee;Jung, Young-Deuk
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.4
    • /
    • pp.17-26
    • /
    • 2020
  • In Korea, primary school (also junior high school) is compulsory and free since 2004. But it looks high school is also compulsory, as over 80% of adults has a high school diploma currently. For 20 years improving high school education is only education-oriented, rather than occupation-oriented. And, the mismatch between the occupational requirement and the lesson from school is getting larger. To resolve this issue, the Korean government builds and utilizes National Competency Standards(NCS) to realize a competence-oriented society. With NCS, the government enables to run of a work-study program and tries to suggest the fundamental solution to improve occupational ability and the unemployment of young people. However, the prejudice against the education level and occupation is still engrained, and it is hard to match the education-career-qualification based on NCS. Therefore, we study NCS from the definition to the utilization, suggest an improving method to flexibly utilized the standards in the fields, and continuously improve and develop the NCS.

A Study on the Measurement of Back Power and the Evaluation of Compression Force at the L_5/S_1$ (요배근력 촉정 및 L_5/S_1$ 요추부하 평가에 관한 연구)

  • Yang, S.H.;Kim, D.S.;Park, P.
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.161-165
    • /
    • 1997
  • Recently, industrial accidents have been getting great damage to an enterprise management directly and indirectly, the industrial injuries of conventional type are decreasing : on the other hand, musculoskeletal injuries are trending to a rapid increase. This shows that most of carrying works have been performing in almost all production process and convey objects, machine equipment and work method. Then, they are made by unfitted design which doesn't consider physical condition of workers, so it causes them to bring about forceful motion. In this paper, it was used NIOSH standard the data of spot. The ergonomic design of machine equipment and the evaluation of biomechanical compression force at theL_5/S_1$and back power, intend to provide the basis which can be applied, compared, and analyzed between before process improvement and after.

  • PDF

An Investigation of ECDIS Type Approval based on International Standard (국제기준에 의한 ECDIS 인증방안 고찰)

  • 심우성;서상현
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.15-19
    • /
    • 2001
  • Electronic navigation system onboard have have been developed with recent technology based on new concept such as electronic chart date. The most valuable system of revolution in electronic navigation equipment is ECDIS, which have been developed in order to reduce work load of mariner and give an integrated information by simple means, especially to improve the safety of ship's navigation. In order to be sure the function of ECDIS is satisfied, The international standard have regulated the performance in the standard, so ECDIS should be type approved by the marine equipment authority of each government. There are three basic documents, IEC61174, IEC61162, IEC60945 issued by IMO(International Maritime Organization) which should be used for type approval system of each authority. IEC 61174 include the method of test and required results for operational and functional performance of test equipment. IEC61162 is for sensor interface and IEC60945 is related to the test of environmental condition for general marine radiocommunication equipment. In this paper, we investigate international standard in detail and current approval system of general marine equipment. After that, we present the possible structure of type approval of ECDIS and important considerations of approval system such that ECDIS should be tested as one system not be separated between S/W and H/W.

  • PDF

Analysis of Workload of the Domestic Coastal Ship Duty Officer to Prevent Marine Accidents (해양사고 예방을 위한 국내 연안선 항해당직자의 업무 부하 분석)

  • Yang, Young Hoon;Kim, Hongtae;Jang, Junhyuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.579-587
    • /
    • 2017
  • Objective: The purpose of this study is to measure the workload of Korea coastal ship crew members, to investigate whether they are following work-break time regulations and to identify the main causes of their workload. Background: According to the US Coast Guard, about 33% of human casualties are reported to be due to fatigue, and 30% of marine casualties reported by the British Marine Accident Investigation Agency (MAIB) are attributed to crew fatigue. But the coastal ship are not managed for business hours and breaks despite the harsh environment. Method: The workload of duty crew members on the 100 domestic coastal vessels was measured. It was also investigated whether they are following domestic and international work-break time regulations. Finally, the marine accidents resulted from the fatigue of the crew was analyzed. Results: As a result of workload analysis, the workload on the 42~62% of the vessels exceeded the standard of working time on the related regulation. The workload increased with the number of inbound and outbound ports. Especially, in the system where there are two seafarers, the workload exceeded the working time requirement. As a result of the marine accidents analysis on 100 vessels, it was found that collision and grounding occurred due to fatigue, workload and drowsiness in 7 marine accidents out of 30 marine accidents. Conclusion: It is necessary for the shipping companies to introduce an operation management manual for the management of the crews' workload and reasonable crew arrangement. It is also required for crew members to easily record work times and for shipping companies to manage the record. It would be possible to prevent many marine accidents by providing adequate rest to the crews and flexibly adjusting their working hours. Application: The results of this study can be used as fundamental data to manage crews' fatigue and to make job management manuals.

Key Technology for Food-Safety Traceability Based on a Combined Two-Dimensional Code

  • Zhonghua Li;Xinghua Sun;Ting Yan;Dong Yang;Guiliang Feng
    • Journal of Information Processing Systems
    • /
    • v.19 no.2
    • /
    • pp.139-148
    • /
    • 2023
  • Current food-traceability platforms suffer from problems such as inconsistent traceability standards, a lack of public credibility, and slow access to data. In this work, a combined code and identification method was designed that can achieve more secure product traceability using the dual anti-counterfeiting technology of a QR code and a hidden code. When the QR code is blurry, the hidden code can still be used to effectively identify food information. Based on this combined code, a food-safety traceability platform was developed. The platform follows unified encoding standards and provides standardized interfaces. Based on this innovation, the platform not only can serve individual food-traceability systems development, but also connect existing traceability systems. These will help to solve the problems such as non-standard traceability content, inconsistent processes, and incompatible system software. The experimental results show that the combined code has higher accuracy. The food-safety traceability platform based on the combined code improves the safety of the traceability process and the integrity of the traceability information. The innovation of this paper is invoking the combined code united the QR code's rapidity and the hidden code's reliability, developing a platform that uses a unified coding standard and provides a standardized interface to resolve the differences between multi-food-traceability systems. Among similar systems, it is the only one that has been connected to the national QR code identification platform. The project has made profits and has significant economic and social benefits.

Determination of 11 Illicit Compounds in Dietary Supplements Using High-Performance Liquid Chromatography and Liquid Chromatography-Tandem Mass Spectrometry

  • Shin, Dasom;Kang, Hui-Seung;Kim, Hyung-soo;Moon, Guiim
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.326-333
    • /
    • 2020
  • In this work, we developed an analytical method for determining 11 illicit compounds in dietary supplements using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry. Eleven target compounds, including those meant for weight loss (7-keto-dihydroepiandrosterone, buformin, metformin, phenformin, salbutamol, and tolbutamide), sexual enhancement (dihydroepiandrosterone), and relaxation (asarone, kavain, magnoflorine, and picamilon) were screened and confirmed in dietary supplements. Method validation was performed by evaluating the selectivity, linearity, limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was > 0.993 for all analytes. The LOQs were ranged in 2.1-9.9 ㎍/mL (HPLC-DAD) and 0.002-0.008 ㎍/mL (LC-MS/MS). The accuracies (expressed as recovery) were 90.0-106% (HPLC-DAD) and 83.0-114% (LC-MS/MS). The precision (expressed as the relative standard deviation) was below 10% using HPLC and LC-MS/MS. The proposed method can be used for the surveillance of illicit compounds in dietary supplements.