• Title/Summary/Keyword: safety joint

Search Result 818, Processing Time 0.034 seconds

Performance Improvement of Pneumatic Artificial Muscle Manipulators Using Magneto-Rheological Brake

  • Ahn, Kyoung-Kwan;Cong Thanh, TU Diep;Ahn, Young-Kong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.778-791
    • /
    • 2005
  • A novel pneumatic artificial muscle actuator (PAM actuator), which has achieved increased popularity to provide the advantages such as high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks, has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. Then it is not easy to realize the performance of transient response of pneumatic artificial muscle manipulator (PAM manipulator) due to the changes in the external inertia load with high speed. In order to realize satisfactory control performance, a variable damper-Magneto­Rheological Brake (MRB), is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control method brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity, uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control method and without regard for the changes of external inertia loads.

Contents of Toxic Metals in Crustaceans Consumed in Korea (유통 갑각류 중 중금속 함량)

  • Kim, Mee-Hye;Lee, Yun-Dong;Park, Hyo-Jung;Kim, Eun-Joung;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.375-378
    • /
    • 2004
  • There are few studies on toxic metals in crustaceans available in Korea. Therefore, this study was conducted to estimate content of toxic metals in crustaceans (n=58). Samples were digested with acids and analysed by inductively coupled plasma spectrometer (ICP) or atomic absorption spectrometer (AAS) for lead (Pb), cadmium (Cd), and arsenic (As). Mercury (Hg) contents were determined using mercury analyzer. Toxic metal contents [minimum-maximum (mean), mg/kg] in crustaceans were as follows; Hg 0.004-0.28 (0.06), Pb ND-0.31 (0.03), Cd 0.003-0.92 (0.14), and As 0.01-35.9 (6.63). Our results demonstrated that metal contents in crustaceans on Korean markets were similar to those reported in other countries. Our average weekly intakes of Pb, Cd, and Hg from crustaceans were lower than 1% of Provisional Tolerable Weekly Intakes (PTWI) set by Joint FAO/WHO Expert Committee for food safety evaluation.

A Case Report of Cyclophosphamide plus Doxorubicin-induced Side effects in Patient with Both Sides Breast Cancer Treated with Integrative Medicine Therapy Including Pharmacopuncture. (유방암 환자의 cyclophosphamide, doxorubicin 유발 부작용에 대한 약침을 포함한 통합 암 치료 1례)

  • Kim, Minserh;Jung, Yu-jin;Hong, Sang-hoon
    • Journal of Korean Traditional Oncology
    • /
    • v.23 no.1
    • /
    • pp.33-43
    • /
    • 2018
  • Objectives: To observe the mitigating effects of a Traditional Korean Medicine(TKM) treatment program especially including pharmacopuncture, with Cyclophosphamide and doxorubicin chemotherapy on a both sides breast cancer patient. Methods: AA 74 year-old female patient diagnosed with both sides breast cancer (Right) pT1bpN0M0, (Left) pT1cpN1Mx was admitted to hospital of Dong-eui university in May of 2017. She received Cyclophosphamide and Doxorubicin from May $31^{st}$ to August $2^{nd}$, 2017 followed by TKM treatment consisting of herbal medicine, acupuncture, moxibustion and pharmacopuncture (Trionycis Carapax, Non-toxic Bee Venom, and Cultivated Wild Ginseng Extract) for a period of almost 4 months, from May $13^{th}$ to August $19^{th}$, 2017. Symptoms were evaluated by the grade of chief complaints refer to Common Terminology Criteria for Adverse Events (CTCAE) and Eastern Cooperative Oncology Group (ECOG). Results: TKM including pharmacopuncture alleviated chemotherapy-induced nausea, fatigue, joint pain, diarrhea, insomnia. Conclusions: This case study potentiates TKM with pharmacopuncture's significant efficacy in aiding breast cancer patients suffering from Cyclophosphamide plus Doxorubicin induced adverse effects. Further research should take place for clear understanding of the exact amount of dosage and safety. Moreover it must be accompanied by long-term follow up researches.

Posterior Atlantoaxial Transarticular Screw Fixation

  • Ko, Byung-Su;Lee, Jung-Kil;Kim, Yeon-Seong;Moon, Sung-Jun;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • Objective : Posterior arthrodesis in atlantoaxial instability has been performed using various posterior C1-2 wiring techniques. Recently, transarticular screw fixation (TASF) technique was introduced to achieve significant immediate stability of the C1-2 joint complex. The purpose of this study is to assess the clinical outcomes associated with posterior C1-2 TASF for the patient of atlantoaxial instability. Methods : We retrospectively reviewed data obtained from 17 patients who underwent C1-2 TASF and supplemented Posterior wiring technique (PWT) with graft between 1994 and 2005. There were 8 men and 9 women with a mean age of 43.5 years (range, 12-65 years). An average follow-up was 26 months (range, 15-108 months). Results : Successful fusions were achieved in 16 of 17 (94%). The pain was improved markedly (3 patients) or resolved completely (14 patients). There was no case of neurological deterioration, hypoglossal nerve injury, or vertebral artery injury. Progression of spinal deformity, screw pullout or breakage, and neurological or vascular complications did not occur. Conclusion : The C1-2 TASF with supplemental wiring provided a high fusion rate. Our result demonstrates that C1-2 TASF supplemented by PWT is a safe and effective procedure for atlantoaxial instability. Preoperative evaluation and planning is mandatory for optimal safety.

Morphological Assessment of Cadaveric Radial, Brachial and Subclavian Arteries : A Neurointerventional Approach

  • Yilmaz, Ali;Ozkul, Ayca;Shin, Dong Seong;Im, Soo-Bin;Yoon, Seok-Mann;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • Objective : The transradial catheterization (TRC) is becoming widespread, primarily for neurointerventions. Therefore, the evaluation of radial artery puncture in clinical practice and a better understanding of the anatomy are important to improve the safety of neuroendovascular surgery. Methods : Ten formalin-fixed adult Korean cadavers were dissected to expose radial artery (RA), brachial artery (BrA) and subclvian artery (ScA), bilaterally. Vessel lengths and diameters were meaured using a caliper and distance between the specific point of vessels and the anatomical landmarks including the radial styloid process, the medial epicondyle of the humerus, the sternoclavicular joint, and the vertebral artery orifice were also measured. Results : The average length between the radial (RAPS) and the BrA puncture sites (BrAPS) and between the vertebral artery orifice (VAO) and the BrA bifurcation (BrAB) did not differ between sides (p>0.05). The average length between the radial styloid process (RSP) and the RAPS was $13.41{\pm}2.19mm$, and the RSP was $26.85{\pm}2.47mm$ from the median nerve (MN). The mean length between the medial epicondyle (ME) and the BrAPS as $44.23{\pm}5.47mm$, whereas the distance between the ME and the MN was $42.23{\pm}4.77mm$. The average VAO-ScA angle was $70.94{\pm}6.12^{\circ}$, and the length between the ScA junction (SCJ) and the VAO was $60.30{\pm}8.48mm$. Conclusion : This study provides basic anatomical information about the radial artery and the brachial route and can help improving new techniques, selection of size and shape of catheters for TRC. This can help neurointerventionists who adopt a transradial neuroendovascular approach and offers comprehensive and safe care to their patients.

Structural performance by strengthening types of wood frames using H shaped steel joints (H형강 접합부를 갖는 목조 골조의 보강형식에 따른 구조성능)

  • Kim, Soon-Chul;Moon, Youn-Joon;Yang, Il-Seung;Park, Geun-Hong
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.77-83
    • /
    • 2008
  • The effective mixture of structural laminated timber and other materials is expected to extend the potentials of building structures because of the potentials to realize high performance in structural safety. The classical joint types using drift pin and bolts are occurred local failures due to the small bearing area. In result, new joints using H shaped steel were suggested in this research. The objective of this study is to evaluate elasto-plastic behaviors by strengthening types of wood frames with new joints connecting structural laminated timber with H shaped steel. A total of five specimens of about one-second scale were tested. Specimens had columns with 1,050 height and $84mm{\times}100mm$ section, and a beams with 1,950mm length and $130mm{\times}100mm$ section. Also, the specimens were stiffened by brace, hwang-toh brick, and autoclaved lightweight concrete. The results of the test showed that the specimen stiffened with autoclaved lightweight concrete was characterized by fairly good strength and stiffness than those of the other specimens. Initial stiffness of H-2.0D-NS specimen with 2 times inserting length of beam height showed 1.33 times than that of H-1.5D-NS specimen. However, the strength of H-2.0D-NS specimen has not improved too much than H-1.5D-NS specimen.

Rotational Stiffness Reduction Factors of End-plate Connection for PEB Using Finite Element Analysis (유한요소해석을 이용한 공업화박판강구조 단부판 접합부의 회전강성감소계수)

  • Lee, Jun-Seop;Shin, Kyung-Jae;Lee, Swoo-Heon;Lee, Hee-Du;Kim, Cheol-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2017
  • The pre-engineered building(PEB) construction has been gradually applied to single story buildings as a practical and efficient alternative to conventional buildings. However, there has been a few structure collapse due to suddenly excessive load. Although a structure design requires accurate and professional skills, the PEB system tends to be designed simply because of complexation of structural analysis for connections. This paper shows the finite element analysis(FEA) using ABAQUS software on bolted connection which was previously tested. The FEA condignly simulated the behavior of bolted connection in PEB system and was in close agreement with experimental results. Then the stiffness reduction factor of the bolted joints that can be used in the actual design is presented through the analysis of the joint parameters.

Inferolateral Entry Point for C2 Pedicle Screw Fixation in High Cervical Lesions

  • Lee, Kwang-Ho;Kang, Dong-Ho;Lee, Chul-Hee;Hwang, Soo-Hyun;Park, In-Sung;Jung, Jin-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.341-347
    • /
    • 2011
  • Objective : The purpose of this retrospective study was to evaluate the efficacy and safety of atlantoaxial stabilization using a new entry point for C2 pedicle screw fixation. Methods : Data were collected from 44 patients undergoing posterior C1 lateral mass screw and C2 screw fixation. The 20 cases were approached by the Harms entry point, 21 by the inferolateral point, and three by pars screw. The new inferolateral entry point of the C2 pedicle was located about 3-5 mm medial to the lateral border of the C2 lateral mass and 5-7 mm superior to the inferior border of the C2-3 facet joint. The screw was inserted at an angle $30^{\circ}$ to $45^{\circ}$ toward the midline in the transverse plane and $40^{\circ}$ to $50^{\circ}$ cephalad in the sagittal plane. Patients received followed-up with clinical examinations, radiographs and/or CT scans. Results : There were 28 males and 16 females. No neurological deterioration or vertebral artery injuries were observed. Five cases showed malpositioned screws (2.84%), with four of the screws showing cortical breaches of the transverse foramen. There were no clinical consequences for these five patients. One screw in the C1 lateral mass had a medial cortical breach. None of the screws were malpositioned in patients treated using the new entry point. There was a significant relationship between two group (p=0.036). Conclusion : Posterior C1-2 screw fixation can be performed safely using the new inferolateral entry point for C2 pedicle screw fixation for the treatment of high cervical lesions.

Intelligent Phase Plane Switching Control of Pneumatic Artificial Muscle Manipulators with Magneto-Rheological Brake

  • Thanh, Tu Diep Cong;Ahn, Kyoung-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1983-1989
    • /
    • 2005
  • Industrial robots are powerful, extremely accurate multi-jointed systems, but they are heavy and highly rigid because of their mechanical structure and motorization. Therefore, sharing the robot working space with its environment is problematic. A novel pneumatic artificial muscle actuator (PAM actuator) has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. Its main advantages are high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks. The PAM is undoubtedly the most promising artificial muscle for the actuation of new types of industrial robots such as Rubber Actuator and PAM manipulators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In addition, the nonlinearities in the PAM manipulator still limit the controllability. Therefore, it is not easy to realize motion with high accuracy and high speed and with respect to various external inertia loads in order to realize a human-friendly therapy robot To overcome these problems a novel controller, which harmonizes a phase plane switching control method with conventional PID controller and the adaptabilities of neural network, is newly proposed. In order to realize satisfactory control performance a variable damper - Magneto-Rheological Brake (MRB) is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control using neural network brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control using neural network and without regard for the changes of external inertia loads.

  • PDF

Trace Metal Contents in Vegetables and Their Safety Evaluations (우리나라 채소류중 미량금속 함량 및 안전성 평가)

  • 정소영;김미혜;소유섭;원경풍;홍무기
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.1
    • /
    • pp.32-36
    • /
    • 2001
  • This study was conducted to estimate the contents of trace metals in vegetable which were produced in Korea. The levels of trace metals determined using a mercury analyzer, and ICP (inductively coupled plasma spectrometer) and an AAS (atomic absorption spectrophotometer) after wet digestion. The values of trace metals [minimum~maximum (mean), mg/kg] in vegetables were a follows ; Hg : 0.0001~0.019 (0.002), Pb : 0.001~0.28 (0.02), Cd : 0.001~0.078 (0.016), As : 0.001~0.06 (0.02), Cu : 0.06~24.81 (0.77), Mn : 0.17~15.12 (2.32), Zn : 0.13~28.70 (2.51). These results showed that metal contents in vegetables on domestic markets were similar to those reported in other countries. The weekly average intakes of lead, cadmium and mercury from vegetables take 2~7% of PTWI (Provisional Tolerable Weekly Intakes) that the FAO/WHO Joint Food Additive and Contaminants Committee had set to evaluate their safeties.

  • PDF