• Title/Summary/Keyword: safety integrity level

Search Result 160, Processing Time 0.038 seconds

Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor (반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

Quantitative Risk Reduction Model according to SIL allocated by Risk Graph for Railway Platform Door System (Risk Graph에 의해 할당된 SIL에 따른 철도 승강장 도어 시스템의 정량적 Risk 저감 모델)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.141-148
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. Especially, in case of the SIL allocation method without determining of quantitative tolerable risk, the additional review is needed to check whether it is suitable or not is required. In this study, the quantitative risk reduction model based on the safety integrity allocation results of railway platform screen door system using Risk Graph method has been examined in order to review the suitability of quantitative risk reduction according to allocated safety integrity level.

Allocation of Safety Integrity Level for Railway Platform Screen Door System based on Consequence Severity and Risk Graph (결과 심각도 및 리스크 그래프에 기반한 철도 승강장 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.164-173
    • /
    • 2015
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, application standard differs from every industry in domestic or international for application on mythology for allocation and demonstration of SIL. Application or assessment is not easy since absence on clear criteria or common definition. This research studied not only fundamental concept of SIL required to guarantee safety in accordance with international standards for safety related equipment and system, but different types of methodologies for SIL allocation. Specifically, SIL allocation for Platform Screen Door system of railway is studied applying methodology of severity of accidents and risk graph among different methodologies for SIL allocation.

An Optimal Design Procedure based on the Safety Integrity Level for Safety-related Systems

  • Kim, Sung Kyu;Kim, Yong Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.12
    • /
    • pp.6079-6097
    • /
    • 2018
  • Safety-related systems (SRSs) has widely used in shipbuilding and power generation to prevent fatal accidents and to protect life and property. Thus, SRS performance is a high priority. The safety integrity level (SIL) is the relative performance level of an SRS with regard to its ability to operate reliably in a safe manner. In this article, we proposed an optimal design procedure to achieve the targeted SIL of SRSs. In addition, a more efficient failure mode and effects diagnostic analysis (FMEDA) process and optimization model were developed to improve cost efficiency. Based on previous IEC 61508 diagnostic analyses that revealed unnecessary costs associated with excessive reliability, the new approach consists of two phases: (i) SIL evaluation by FMEDA, and (ii) solution optimization for achieving the target SIL with minimal cost using integer-programming models. The proposed procedure meets the required safety level and minimizes system costs. A case study involving a gas-detection SRS was conducted to demonstrate the effectiveness of the new procedure.

Safety Evaluation according to Controller Configuration using Safety Integrity Level (안전 무결성 등급을 이용한 제어기의 구성에 따른 안전성 평가)

  • Kim, Jong-Hoon;Lee, Dae-Jong;Lee, Ho-Hyun;Chun, Myung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.43-47
    • /
    • 2017
  • A SIL(Safety Integrity Level) assignment method is used for preventing failure action. The goal of safety system for processing automation is to reduce the human fatal risk. Even if we have developed the processing automation according to developing technology, we are also realized on increasing the human fatal risk cause of unexpected accidents. This study is directed the solution of decision for safety level for safety system and the best architecture for safety system in process automation.

A Study of Risk Reduction by SIL(Safety Integrity Level) Determination (SIL(Safety Integrity Level) 선택에 의한 리스크 감소에 관한 연구)

  • Kim, Jung-Hwan;Kim, Bum-Su;Yang, Jae-Mo;Jang, Chang-Bong;Kim, Min-Seop;Jung, Sang-Yong;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.57-62
    • /
    • 2011
  • Modern chemical plants including petroleum refinery and gas industries have evolved into more complex and specialized. In these industrial complexes, it is important to maintain acceptable safety level protecting from various potential disasters caused by fire, explosion and the leakage of toxic materials. Recently possibility and consequence of accidents are increasing in the industrial process. So there is a trade-off between the plant operation efficiency and safety level. In this study SIF(Safety instrument Functions) was incorporated into SIL(Safety Integrity Levels). As a result, the safety level was upgraded by designing resonable allocation of safety instruments.

ISO 26262 의 하드웨어 ASIL 정량적 평가 절차

  • Kim, Gi-Yeong;Jang, Jung-Sun
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.271-279
    • /
    • 2011
  • Automotive safety integrity level of hardware components can be achieved by satisfying quantitative and qualitative requirements. Based on ASIL, quantitative requirements are composed of hardware architectural metrics and evaluation of safety goal violations due to random hardware failures in ISO 26262. In this paper, the types of hardware failures will be defined and classified. Based on various metrics related with hardware failures, design essentials to achieve hardware safety integrity will be studied specifically. Issues associated with hardware development and assessment process are presented briefly.

  • PDF

Study on ISA's assessment to software process for EN50128 SIL4 (EN50128 SIL4 소프트웨어 프로세스 ISA 인증 사례 연구)

  • Cho, Chi-Hwan;Kang, Chan-Yong;Hwang, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.838-849
    • /
    • 2010
  • It is inevitable to control the systematic failure to obtain the software safety integrity of embedded software installed in rolling stock. Because it is not possible to assess systematic failure integrity by quantitative methods, SILs are used to group documentation, methods, tools and techniques throughout software development lifecycle which, when used effectively, are considered to provide an appropriate level of confidence in the realization of a system to a stated integrity level. Normally, safety approval process is through generic product, generic application and specification application for. For safety approval on generic application of software based system, it is required to apply the certified software processes from the planning stage for the assigned SIL. As such, we will develop project specific application with high safety integrity within time limit of contractual delivery schedule through software assessment to the modified area with the re-use of certified software module and documentation. At this point, Hyundai Rotem has developed software processes applicable to support SIL 4 based on EN50128 which was assessed and certified by TUV SUD. This paper introduces the Hyundai Rotem's detailed approach and prospective action to achieve software safety integrity level.

  • PDF

Assessment Procedure of Safety Integrity Level(SIL) Based on Flowchart (플로우차트 기반 안전무결성수준 평가 절차)

  • Kim, Gi-Young;Ko, Byeong-Gak;Jang, Joong-Soon;Chan, Sung-Il
    • Journal of Applied Reliability
    • /
    • v.10 no.2
    • /
    • pp.107-122
    • /
    • 2010
  • Functional safety is the part of the overall safety of a system that depends on the system or equipment operating correctly in response to its inputs, including the safe management of likely operator errors, hardware failures, systematic failures, and environmental changes. One of the essential concepts of functional safety is Safety Integrity Level(SIL). It is defined as a relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction. In this paper, each element of SIL assessment will be defined. Based on each element, specific process of SIL selection will be established by using flowchart. The flowchart provides a SIL assessment guideline for functional safety engineers. The proposed theory will be verified by applying to a oil refining plant for SIL assessment.

A Study on a Safety Life Cycle of IEC 61508 for Functional Safety (기능안전을 위한 IEC 61508의 안전수명주기에 관한 연구)

  • Kim, Sung Kyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.81-91
    • /
    • 2014
  • The IEC 61508 standard was established to specify the functional safety of E/E/PE safety-related systems. Safety life cycle to provide the framework and direction for the application of IEC 61508 is included in this standard. In this paper, we describe overviews, objects, scopes, requirements and activities of each phase in safety life cycle. In addition, we introduce safety integrity level(SIL) which is used for verifying the safety integrity requirements of E/E/PE system and perform a case study to estimate hardware SIL by FMEDA. The SIL is evaluated by two criteria. One of them is the architectural constraints which restrict the maximum SIL by combination of SFF and HFT. The other is the probability of failure which is classified into PFD and PFH based on frequency of demand and calculated by safe or dangerous failure rates.