• Title/Summary/Keyword: safety diagnosis

Search Result 982, Processing Time 0.023 seconds

Development of Shearing Machine Fault & Safety Diagnosis System Using Expert System (Expert System을 이용한 전단기 고장 및 안전진단 시스템 구축)

  • 강경식;나승훈;정영득;박재현
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.475-483
    • /
    • 1997
  • Industrial safety management program consists of three part which is education, technology and control. The effectiveness of industrial safety control program rely on the ability of controlling hardware system, technology and software, training and management. How to design and develop the sharing machine fault and safety diagnosis system using expert system technique is presented on this paper.

  • PDF

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

On Study the Safety Diagnosis of Carbody Structure for Crashed Electric Multiple Units (사고전동차 구조체의 안전진단에 관한 고찰)

  • Bae Dae-Sung;Park Geun-Soo;Chung Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.253-259
    • /
    • 2005
  • This paper describes 3D Dimensional Measurement(EDM testing) and tensile testing results of carbody structure for crashed EMU(Electric Multiple Units). Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the crashed EMU. And Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The testing results have been used to provide the critical information for the criteria of safety diagnosis.

A Study on the Improvement of Member Evaluation Method in the Condition Evaluation of Reinforced Concrete Buildings (철근콘크리트 건축물의 상태평가 중 부재평가방법 개선에 관한 연구)

  • Woo, Hye-Sung;Yi, Waon-Ho;Hwang, Kyung-Ran;Lee, Kwan-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.85-91
    • /
    • 2021
  • Type 1 and type 2 buildings must regularly conduct precise safety inspections and precise safety diagnosis for the safety and maintenance of facilities, and the safety grade of the building is determined according to the results of the implementation. In addition, the cycle of inspection and diagnosis is determined according to the safety grade of the building. In order to determine the safety grade of the building, a precise safety inspection conducts condition evaluation, and a precise safety diagnosis conducts condition evaluation and safety evaluation. Therefore, since the inspection and diagnosis cycle is determined according to the safety grade of the building, the condition evaluation and safety evaluation must be precise. However, in the case of member unit evaluation, which is the first step in evaluating the current condition, the evaluation grade is determined by using the representative value of the measurement result, and this may result in an error in the evaluation grade. To solve this problem, this study analyzed evaluation criteria for each evaluation item and presented evaluation criteria using inequalities to respond to measurement results and evaluation scores. In addition, we present a functional formula that can reflect performance scores for each evaluation item.

The AHP Method to Quantitate Investigation Items of Cut Slope (계층분석과정을 통한 절토사면 조사항목의 정량화)

  • Lee, Jong-Young;Shin, Chang-Gun;Kim, Yong-Soo;An, Sang-Lo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.732-737
    • /
    • 2006
  • The facility diagnosis technique of past subjective judged the technical expert and interpreted stably mainly. The facility the periodical civil official becomes indispensability consequently with the law and the system and objectivity inspection which relates with a this and development of diagnosis technique were necessary. Currently the evaluation elements which relate with an inspection and diagnosis technique depended to the subjectivity of each facility quality, data statistics, diagnosis know-how, various circumstance and the technical expert and the evaluation item came to decide. But the evaluation score distribution of marks of each item depended plentifully in data analysis result and experience. The past method is weak in logically because the objection theoretical background and basis are insufficiency. Consequently in order to apply a data analysis result and an experience logically, it used AHP(Analytic Hierarchy Process) method from this research. It is visible with the fact that the application result reconfirmation and complement process will be necessary the technique which is suitable in the multi facility management. Also it is expected with the fact that the application characteristic from the next relation technique will be excellent.

  • PDF

Diagnosis of Poor Contact Fault in the Power Cable Using SSTDR (SSTDR을 이용한 케이블의 접촉 불량 고장 진단)

  • Kim, Taek-Hee;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1442-1449
    • /
    • 2016
  • This paper proposes a diagnosis to detecting poor contact fault and fault location. Electrical fire by poor contact fault of power cable occupied a large proportion in the total electrical installations. The proposed method has an object to prevent electrical fault in advance. But detecting poor contact fault is difficult to detect fault type and fault location by using conventional reflectometry due to faults generated intermittently and repeatedly on the time change. Therefore, in this paper poor contact fault and fault conditions were defined. System generating poor contact fault produced for the experimental setup. SSTDR and algorithm of reference signal elimination heighten performance detecting poor contact fault on live power cable. The diagnosis methods of signal process and analysis of reflected signal was proposed for detecting poor contact fault and fault location. The poor contact fault and location had been detected through proposed diagnosis methods. The fault location and error rate of detection were verified detecting accuracy by experiment results.

A Study on the Convergence Safety Management Improvement of Hazardous Material Facilities (위험물시설의 융합형 안전관리 개선방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.47-53
    • /
    • 2018
  • The actual condition of safety management and problems for hazardous material facilities in national industrial complex are investigated and analyzed in fields of hazardous material facilities safety, fire fighting equipment safety, building safety, space safety. In most cases, the failure to comply with legal requirements and the maintenance of fire safety have been pointed out. As a result, the total number of problems identified was 466 and problems in the field of hazardous material facilities safety have been pointed out the most. Also, it was analyzed that the number of problems identified in the manufacturing facilities and general handling centers among the hazardous materials facilities was the highest. Therefore, it will contribute to strengthening the safety management capability of the national industrial complex in the future by suggesting the convergence direction of the safety diagnosis system and the systematic introduction of the precise safety diagnosis.

A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents (전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석)

  • Kim, Han-Sang;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.

Parameter identifiability of Boolean networks with application to fault diagnosis of nuclear plants

  • Dong, Zhe;Pan, Yifei;Huang, Xiaojin
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.599-605
    • /
    • 2018
  • Fault diagnosis depends critically on the selection of sensors monitoring crucial process variables. Boolean network (BN) is composed of nodes and directed edges, where the node state is quantized to the Boolean values of True or False and is determined by the logical functions of the network parameters and the states of other nodes with edges directed to this node. Since BN can describe the fault propagation in a sensor network, it can be applied to propose sensor selection strategy for fault diagnosis. In this article, a sufficient condition for parameter identifiability of BN is first proposed, based on which the sufficient condition for fault identifiability of a sensor network is given. Then, the fault identifiability condition induces a sensor selection strategy for sensor selection. Finally, the theoretical result is applied to the fault diagnosis-oriented sensor selection for a nuclear heating reactor plant, and both the numerical computation and simulation results verify the feasibility of the newly built BN-based sensor selection strategy.