• Title/Summary/Keyword: safety device

Search Result 1,809, Processing Time 0.027 seconds

Door Control Unit Create Provision for PID Control DB (도어제어장치(DCU)의 PID Control DB 생성장치)

  • Kim, Jin-Heon;Kwon, Young-Hyun;Seong, Chang-Yong;Kwon, Min-Jeong;Lee, Han-Su
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3065-3072
    • /
    • 2011
  • PID Control Data Base creation device of DCU is safety operation technology of train door. For keeping the normal condition of door, measured value of regular condition and unusual(trouble detected) condition should be recorded by encoding. The door should be measured itself as this value is compared with standard vale. If it's condition of the door and for reaching the datum point and ot does self-diagnosis. This aim for Technical Realization is that carry out safety train operation by using the Estimation Data Base and protect before door-trouble.

  • PDF

A proposal to build comprehensive maritime safety communication networks (해상 안전 종합통신망 구축 제안)

  • Yang, Gyu-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.6
    • /
    • pp.920-926
    • /
    • 2012
  • In this paper, marine accidents recently happened in Korea and Japan for 5 years, especially through the analysis of accident characteristics for fishing vessels, including small vessels were analyzed. Also propose a new maritime safety communication network in the form of a comprehensive considering the wave propagation characteristics and operational characteristics of radio communication equipments should be installed in the vessel through comprehensive analysis of the regulation according to the radio equipment and the ship's location identification device installation and operation.

Quenching Effects of Acetylene, Hydrogen-Oxygen Detonation (폭굉제어기에 의한 수소. 아세틸렌 산소 혼합가스의 폭굉제어)

  • 김한석;문정기
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • Quenching effects of acetylene and hydrogen into oxygen detonation by using detonation arrester [DA]are studied in this paper. The experiments were carried out in cylinderical shock tube. 5m long, 30mm dia., with stolchlometric ratio [SR]of each gas and 10-l20$\mu$ Cell Size of brass and Stainless Steel of DAs were installed in it To clarify arresting ability correlation with initial pressure, Pi, critical thickness, Tct, and shapes of supporting panel of DA are also investigated It is found that ­detonation velocities has most dependency on Pi, it shows notable changes around 0.5kgf/$\textrm{cm}^2$ for hydrogen, 0.15kgf/$\textrm{cm}^2$ for acetylen respectively, ­DA can be safety device able to arrest shock wave of detonation, ­over Tct flame transmission might be only the factor has to be considered, ­acetylene seems to be much more stronger detonation characteristics than hydrogen because of reaction heat.

  • PDF

Reliability Analysis of Stowage System of Container Crane using Subset Simulation with Markov Chain Monte Carlo Sampling (마르코프 연쇄 몬테 카를로 샘플링과 부분집합 시뮬레이션을 사용한 컨테이너 크레인 계류 시스템의 신뢰성 해석)

  • Park, Wonsuk;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.54-59
    • /
    • 2017
  • This paper presents an efficient finite analysis model and a simulation-based reliability analysis method for stowage device system failure of a container crane with respect to lateral load. A quasi-static analysis model is introduced to simulate the nonlinear resistance characteristics and failure of tie-down and stowage pin, which are the main structural stowage devices of a crane. As a reliability analysis method, a subset simulation method is applied considering the uncertainties of later load and mechanical characteristic parameters of stowage devices. An efficient Markov chain Monte Carlo (MCMC) method is applied to sample random variables. Analysis result shows that the proposed model is able to estimate the probability of failure of crane system effectively which cannot be calculated practically by crude Monte Carlo simulation method.

Seismic Response Enhancement through Stiffness Connection of Two Adjacent Buildings equipped with ATMD (ATMD가 설치된 두 인접빌딩간 강성연결방식을 통한 내진성능 개선)

  • Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.47-53
    • /
    • 2017
  • In this study, we propose a new control system that effectively utilizes the interaction effect of control force through the connection of stiffness member for seismic performance enhancement of two adjacent structures equipped with active tuned mass damper (ATMD). The efficiency of the proposed control system is verified by comparing with the existing independent control system through the numerical simulations of the 10th- and 12th-story buildings. From the numerical results, it is confirmed that the proposed method can show similar or better control performance even with more economical control capacity than the existing independent control system. Another advantage is that the existing system does not exhibit the adaptive control performance in emergency of failure of one control device, whereas the proposed system can achieve successful adaptive control performance by economically and efficiently utilizing the interacting control effect through the connection member.

A Study on Safety of Drycleaning Solvents (드라이클리닝 용제의 안전성에 관한 고찰)

  • 신정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.2
    • /
    • pp.35-43
    • /
    • 1992
  • This study is to investigate the problems of pollution caused by drycleaning solvents. From the problem of each solvents, safety count-step have to set up. It is following. 1) Solvent: Smong phenomenon of optical chemistry. It has to develop safety tumbler that is attached retrievable device. 2) Perchloroethylene: Pollution of underground water and cause of cancer. Considering the influence on environment and human bing, it has to set up more strong safty plan than now. 3) Chlorofluorocabon : Destory of ozon layer and green house effect on earth. It is being to stop the production until the early part of the year 2000. So it is developing a substitute for chlorofluorocarbon. 4) 1,1,1-trichloroethane : Pollution of underground water and destroy of ozon layzer. At the end of the year 2004, there will be end production of it.

  • PDF

Evaluation of EuroSID-2 & WorldSID in Pole Side Impact (기둥측면충돌시험에서 EuroSID-2와 WorldSID 인체모형 평가에 관한 연구)

  • Kim, Dea Up;Woo, Chang Gi
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.1
    • /
    • pp.40-44
    • /
    • 2015
  • In recent years, WorldSID dummy has been continuously developed and investigated to be a better represent biolfidelic ATD as well as a device for replacement of the current existing EuroSID-2. In Korea, the side impact accident is one of the major severe accidents in terms of numbers of accidents and fatality. Since 2003, 50kph 90degree side crash test has been initiated as a safety standard with EuroSID-1 at the first stage and also same time 55kph impact speed test has been conducted as a part of KNCAP program. Currently only EuroSID-2 is accepted as a regulatory tool for vehicle certification and KNCAP. In order to make use of WorldSID of KNCAP in the distant futuer the tests with WorldSID is conducted experimentally.

The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-man;Park, Jong-ho;Kim, Kyung-yup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

- Development of Digital Fluoroscopic Image Recording System for Customer Safety - (고객 안전을 위한 디지털 방사선장치(DRF)의 투시영상기록장치 개발)

  • Rhim Jae Dong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Many system devices for fluoroscopic and general X-ray studies in diagnostic radiographic system have been being changed from analog mode to digital mode. In addition, among diagnostic imaging and radiologic examinations, fluoroscopic studies that requires functional diagnosis is being widely used. The video recording method of fluoroscopic studies has been useful in functional image diagnosis and dynamic image observation, but the utility of its image quality is being reduced because of limitation in setting play segments of the video player, inconvenience of play, difficulties in preserving reproduced images, the change of image quality, etc. In order to complement these shortages, it is necessary to facilitate access to patient diagnosis information such as storing, editing and sharing functional diagnosis images in response to the trend of the digitalization of digital radiographic & fluoroscopic system(DRF). Thus this study designed and implemented a device of storing functional dynamic images real time using a computer rather than existing video recording, aiming at contribution to functional image diagnosis.

Study on the Utilization of HBD in the Conventional Speed-up Lines (일반철도 고속화 구간에서 차축온도검지장치 활용방안에 대한 연구)

  • Choe, Gwon-Hui;Kim, Yu-Ho;Baek, Seung-Mun;Bing, Gun-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.233-243
    • /
    • 2012
  • HBD(Hot Box Detector) is a device to monitor temperature rises to inappropriate lubricant use or mechanical defects. If a train operates without recognizing such an effect, it might result in bearing overheating due to defects and cause a dangerous situation that it could derail a train owing to the damage of axles. Now for the Gyeongbu HSL at 300km/h, the laws related to monitoring overheated axle bearings are notified in the Railway Safety Law and the Railway Construction Law. But in case of the conventional speed-up lines that a train operates at 180 to 230 km/h, the revised bill of relevant standards is ongoing. Therefore in this paper we present references and reviews investigated in order to use the optimal HBD in the conventional speed-up lines.

  • PDF