• Title/Summary/Keyword: safety device

Search Result 1,809, Processing Time 0.032 seconds

International Standards of Electrical Equipments for Medical Practice (의료용 전기기기에 대한 국제표준 현황)

  • Lee, Tae-Bum
    • The Korean Journal of Health Service Management
    • /
    • v.7 no.3
    • /
    • pp.203-212
    • /
    • 2013
  • Medical devices separated by a committee of the International Electrotechnical Commission IEC TC (Technical Committee) 62 medical electrical equipment being promoted by the International standards. Actually, a lot of standards were existed, but many national and international standards for medical devices were lacking in practical standards that can be applied to their development. Most international standards were focused in electrical and mechanical safety of medical devices. Therefore, there were few practical standards which contain essential performance evaluation. Although medical device regulations do not enforce a fixed lifecycle model, activities are presented in a sequential manner, thus hinting at a waterfall process. Meanwhile, for a decade or more, software teams have benefitted from agile development methods. Several medical device manufacturers have adopted agile practices while keeping development in compliance with regulations, but conflicts arise and decisions have to be taken in favor of agility or formality. However, if there are new practical standards of medical devices, it must be possible to promote the medical devices industry in their nation. To do this, there is a need to develop a new standard could apply to the international market through the analysis of the medical device related technology. Consequently, new standards such as NP (New proposal) or NWIP (New Work Item Proposal) should be developed through international standardization of medical device technology.

State and subject of health and sports medical devices industry at oversea

  • Seo, Jung-Hwa;Kim, Se-Jin
    • Journal of Sport and Applied Science
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • Most of people do not remind of 'Who is domestic medical device business?' A lot of people that Johnson and Johnson, GE and Philips and other foreign companies belong to medical device company. In fact, local enterprises small place based on world market. Local medical device industry's production has grown up rapidly last 10 years. Sales increased nearly 3 times from trillion and 500 billion KRW in 2004 to 4 trillion and 600 billion KRW in 2014. The production record constantly increased owing to safety and good quality of domestic medical devices. As many as 59% of medical devices made in Korea is exported to 198 countries in the world. Currently, medical device industry in the world has been given considerable attention. Cognition and awareness are very much low. Medical device industry, high income creating industry, is said to next generation industry to increase scale, and Korea does not follow world flow. The industry is given support from the government that is not enough. Korean enterprises have small scale among a lot of global enterprises. Being interested in development of medical devices, the author selected department of IT at college.

Inadvertent Complication of a Pipeline Embolization Device for Treatment with Vertebral Artery Dissecting Aneurysm : Distal Tip Fracture of Delivery Wire

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.521-524
    • /
    • 2016
  • Use of the Pipeline embolization device (PED) has increased based on studies about its safety and effectiveness, and new reports that describe perior postprocedural complications are now emerging. We report a rare periprocedural device-related complication that occurred during endovascular treatment with the pipeline embolization device for a dissecting aneurysm on the vertebral artery. A 55-year old woman was admitted due to left medullary infarction, and angiography showed a fusiform dilatation in the left vertebral artery that was suspicious for dissecting aneurysm. Endovascular treatment with PED was planned. Under general anesthesia, the procedure was performed without significant problems and a PED was deployed in an appropriate position. However, in the final step of the procedure, the distal tip of the PED delivery wire became engaged within a small branch of the posterior cerebral artery and fractured. Fortunately, imaging studies after the procedure revealed neither hemorrhagic nor ischemic stroke, and the patient recovered without neurological morbidities except initial symptoms.

Modeling and Simulation of a Shape Memory Release Device (형상기억합금을 이용한 분리장치의 모델 및 모사에 관한 연구)

  • Lee, Yeung-Jo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.99-108
    • /
    • 2006
  • Aerospace applications use pyrotechnic devices with many different functions. Functional shock, safety, overall system cost issue, and availability of new technologies, however, question the continued use of these mechanisms on aerospace applications. Release device is an important example of a task usually executed by pyrotechnic mechanisms. Many aerospace applications like satellite solar panels deployment or weather balloon separation need a release device. Several incidents, where pyrotechnic mechanisms could be responsible for spacecraft failure, have been encouraging new designs for these devices. The Frangibolt is a non explosive device which comprises a commercially available bolt and a small collar made of shape memory alloy (SMA) that replace conventional explosive bolt systems. This paper presents the modeling and simulation of Frangiblot by the change of bolt size and notch geometry. This analysis may contribute to improve the Frangibolt design.

A Study on the Stability of Torque for Compressing-Cutting Device of Nano Tube Manufacturing System Using DC Servo Motor (DC 서보모터를 이용한 나노튜브 제조용 압축-절단 장치의 토크 안전성에 관한 연구)

  • Choi, Kab-Yong;Oh, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5393-5397
    • /
    • 2011
  • The compressing-cutting device is used for manufacturing nano tube. the purpose of this study is to design and manufacture the compressing-cutting device witch has safety and stable performance. The most important core technology, in nano tube manufacturing, is to seam the each end of tube with appropriate pressure and to cut it off into the two part safely not to leak injected medium. Since the compressing pressure and the cutoff speed make the quality of nano tube, they are very important. This study will show the processes of design and manufacturing of compressing-cutting device.

A Design of Secure Communication Framework for Device Management and User Authentication in Wireless Network Environment (무선 네트워크 환경에서 기기 관리 및 사용자 인증을 위한 안전한 통신 프레임워크 설계)

  • Park, JungOh
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.2
    • /
    • pp.43-52
    • /
    • 2019
  • The recent technological developments of smart devices, multiple services are provided to enhance the users' quality of life including smart city, smart energy, smart car, smart healthcare, smart home, and so on. Academia and industries try to provide the users with convenient services upon seamless technological research and developments. Also, whenever and wherever a variety of services can be used without any limitation on the place and time upon connecting with different types of devices. However, security weaknesses due to integrations of multiple technological elements have been detected resulting in the leakage of user information, account hacking, and privacy leakage, threats to people's lives by device operation have been raised. In this paper, safer communication framework is suggested by device control and user authentication in the mobile network environment. After implementations of registration and authentication processes by users and devices, safe communication protocol is designed based on this. Also, renewal process is designed according to the safe control of the device. In the performance evaluation, safety was analyzed on the attack of protocol change weakness occurred in the existing system, service halt, data leakage, illegal operation control of message, and so on, which confirmed the enhanced speed approximately by 8% and 23% in the communication and verification parts, respectively, compared to the existing system.

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

Field Empirical Result Analysis According to the Operation Reliability Test of the Wireless Gas Shut-off Device (무선가스 차단 장치 동작 신뢰성 시험에 따른 현장 실증 결과분석)

  • Hwang, Do-Yeon;Lee, Kyung-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.70-77
    • /
    • 2021
  • As IoT technology develops along with the 4th industrial revolution, gas safety products to which IoT technology is applied are being developed. However, since the gas safety system was not allowed, system improvement and operation reliability test for IoT gas safety products are required. This thesis researches IoT fuse cock and smart multi-function meter among IoT gas safety products, and analyzes the empirical data of IoT fuse cock to secure operational reliability data, thereby becoming a leader in IoT gas safety products. It aims to develop gas barrier technology one step further through various test evaluations and methods in the future.

Development of a 4-DOF Continuum Robot Using a Spring Backbone (스프링 구조를 이용한 4자유도 연속체 로봇의 개발)

  • Yoon, Hyun-Soo;Yi, Byung-Ju
    • The Journal of Korea Robotics Society
    • /
    • v.3 no.4
    • /
    • pp.323-330
    • /
    • 2008
  • This work deals with a 4-DOF flexible continuum robot that employs a spring as its backbone. The mechanism consists of two modules and each module has 2 DOF. The special features of the proposed mechanism are the flexibility and the backdrivability of the whole body by using a spring backbone. Thus, even in the case of collision with human body, this device can ensure safety. The design and the kinematics for this continuum mechanism are introduced. The performance of this continuum mechanism was shown through simulation and experiment.

  • PDF