• Title/Summary/Keyword: safety device

Search Result 1,809, Processing Time 0.032 seconds

A Study on Risk and Safety measures of the Improved Explosive Device (사제폭발물의 위험성 및 안전대책에 관한 연구)

  • Han, Jae-Hoon;Choi, Min-Ki;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.193-202
    • /
    • 2014
  • Crimes with explosives is one of the mass-destructive crimes that involves the most victims. It is heavily punished under the Korean laws. Mid-eastern area is one of the leading places that are home to improvised explosive device attacks, in the form of religious or political terrorism because of its convenience of use, production and disguise. Improvised bombs are permeating into domestic crimes in Korea as their tools. Use of explosive substances are strictly restricted in this country, but it is not impossible to find its information online and to create private explosives with a bit of interest. And they are being traded in the grey market. For this reason, this thesis offers the method of an efficient safety control of explosive substances, which can be used as raw materials for improvised explosive devices, in order to protect citizens' lives and properties and to promote national security down the road.

Man-Machine Interface Device for Dismantling Factory

  • Yi, Hwa-Cho;Park, Jung-Whan;Park, Myon Woong;Nam, Taek-Jun
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • In dismantling factories for recycling, it is important to input actual working data to a personal computer (PC) in order to monitor the work results and related recycling rate of the inputs. This should be performed with a keyboard, a mouse, or other devices. But when a worker is working in the factory, it could be bothersome or time consuming to go to the PC. Especially, workers who works at dismantling factories have a generally low education level are scared to use a PC, which could be used as a pretext for not using the PC. In some cases, data input is performed by a worker after the day's job. In this case, it could take additional time, the worker can make more mistakes, and the data could be unreliable. In this study, we developed a man-machine interface (MMI) device using a safety helmet. A joystick-like device, pushbuttons, and a radio frequency (RF) device for wireless communication is equipped in a safety helmet. This MMI device has functions similar to a PC mouse, and it has a long communication distance. RF is used because it consumes less battery power than Bluetooth. With this MMI device, workers need not go to a PC to input data or to control the PC, and they can control the PC from a long distance. The efficiency of PCs in a factory could be increased by using the developed MMI system, and workers at the dismantling factories could have less reluctance in using the PC.

Development of Collision Tester for Performance Evaluation of Safety Fence in Baseball Stadiums (야구장 안전펜스 성능평가를 위한 충돌시험기 개발)

  • Han, Eui Don;Jang, Woong Ki;Kho, Sun Tak;Kwak, Ho Taek;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.957-962
    • /
    • 2013
  • This paper presents a performance testing device for safety fences of domestic professional baseball stadiums. Safety fences of professional stadiums have been fabricated and installed without adhering to any safety regulations, safety fences demonstrate critically low safety performances and many outfielders are severely injured every season. In this study, we designed and fabricated a performance testing device for safety fences and investigated its validity and reproducibility. A HIC (head injury criterion) was used for the statistical analysis of colliding data. We found that the optimal expulsion pressure and eliminated the accelerometer by replacing it with a velocity sensor using an estimation of the correlation between the momentum data obtained from velocity sensor and the impulse data from the accelerometer.

Injury Study of Older Children Anthropomorphic Test Device with CRS Harness Belt and Vehicle Level Crash Test (CRS 하네스 벨트 사용에 따른 어린이 인체 모형 상해 연구 및 실차 레벨 충돌 평가)

  • Kang, Seungkyu;Yang, Minho;Kim, Jeonghan;Jin, Jeongmoon;Lee, Sooyul
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.3
    • /
    • pp.31-38
    • /
    • 2017
  • For years, Q1.5 (anthropomorphic test device for 1.5 years old infant) and Q3 (anthropomorphic test device for 3 years old infant) dummy protection has been improved considerably by the effort of EuroNCAP. ISOFIX strength of vehicle structure has increased and many child occupant protection tests have made child restraint system (hereafter CRS) optimized for child safety. However, from 2016, EuroNCAP changed the dummy which is used for the child occupant protection from Q1.5/Q3 to Q6/Q10 and these were also adopted in KNCAP from 2017. Therefore, a new method is required to secure the safety for older children In this research, child dummies were tested by using adult safety systems, and the different results from each adult restraint system were compared. Finally, dummies were tested with the CRS harness belt commonly used for infants, which has yielded significant result. In this research, mid-sized sedan and small SUV were used for the test. The researchers of this paper performed sled tests to correlate between the different adult safety belt system and child injury. Following the sled test, an actual vehicle test was conducted to gather the injury data of Q-dummy with the CRS harness belts. This paper will show the advantages of applying a pre-tensioner in the second row for child protection and the necessity of CRS which has its own harness belts to improve safety for older children.

A Study on the Application of Systematic Literature Review for Post-Market Clinical Evaluation of Medical Devices: Focused on the Ophthalmic Electrosurgical system (시판 후 의료기기 임상평가를 위한 체계적 문헌고찰 활용 방안 연구: 안과용전기수술기 사례를 중심으로)

  • Kim, Byung Gwan;Choi, Young Sook;Kim, Mi Sun;Yang, Seok-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.35-41
    • /
    • 2020
  • In this study, we examined whether the systematic literature review method used in the field of evidence-based medicine could be used for post-market clinical evaluation of medical devices by modifying them to fit the regulatory perspective of medical devices in Korea. For this purpose, systematic literature review was modified and applied to conduct a clinical literature survey on the ophthalmic electrosurgical system(Trabectome®, NeoMediX Corp) used for the treatment of glaucoma. A total of six documents were finally selected, and clinical safety and efficacy information on the indications of the ophthalmic electrosurgical system were effectively presented. In addition, general safety information and unexpected safety information could be distinguished through comparison with medical device adverse event reporting cases. The method used in this study is expected to be used in various ways throughout post-market medical device safety management system and for the purpose of regulation improvement, especially in the field of ophthalmic electrosurgical system.

Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device (3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정)

  • Lee, Mun Hyung;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

Shear Fracture Behavior of Anchor Systems for Shock Transmission Unit in RC Bridge (철근콘크리트 교량의 충격전달장치 앵커시스템의 전단파괴거동)

  • 김태상;송하원;변근주;안창모
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1097-1102
    • /
    • 2001
  • Seismic safety of continuous span concrete bridge can be enhanced by distributing a large seismic lateral load to each supporting pier. A new viscoelastic device called Shock Transmission Unit(STU), which is a simple cylinder-piston assembly packed with a so-called silicone putty compound, enables the lateral seismic load to be transmitted to the pier by installation of the device to movable bearings of the bridge. The seismic safety of concrete bridges having the STU depends on not only safety of the bridges globally but also safety of anchor systems which anchors the STU to concrete pier. An experimental investigation is performed to study the behavior of cast-in-place anchor and post-installed anchor subjected to shear load statically and cyclically according to different edge distance, embedment length, and anchor spacing. Finally, the experimental results are compared with results by design methods of ACI and CCD, and results by FEM analysis.

  • PDF

Reagent Cabinet Management System Using Danger Priority

  • Cao, Kerang;Kang, Inshik;Choi, Hyungwook;Jung, Hoekyung
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.227-231
    • /
    • 2017
  • Recently, as the number of safety accidents caused by reagents increases, researches on a system that can reduce safety accidents are underway. Existing systems managed reagent cabinet through various sensors. On the other hand, there are disadvantages in that countermeasures against simultaneous danger situations are insufficient at multi-reagents cabinet. In order to solve this problem, this paper proposes a system to manage the reagents cabinet through danger priority. Danger priorities are selected through domestic chemical accident cases and the Chemical Safety Management Act. If a danger situation occurs in the reagent cabinet, make sure it is from a single or multiple reagent cabinets. For multiple reagent cabinets, compare the reagent cabinet priorities and run the device sequentially from the reagent cabinet with the highest priority. Thus, by operating the device according to the danger priority, the chain reaction can be prevented in advance and the reagent cabinet can be safely managed.

Structural Analysis of Cold Draw Bar Packaging Automation System (Cold Drawn Bar 포장 자동화 기계설비에 관한 구조해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.63-68
    • /
    • 2020
  • In this study, we analyzed a cold draw (CD) bar packaging automation facility to examine its structural safety. The structural analysis focused on the frame part of the automatic packing machine for the CD round rod widely used in the industrial field, as well as the package supply device, banding suit, and crane part. As a result, we concluded that the structural safety for the banding suit, crane, and package supply device have been secured (safety factors of 9.8, 7.5, and 14.5, respectively). In addition, the safety factor of the transfer was 4.0.

Analysis of the Main Factor of Wheel Loader Torque via Wireless Measurements (무선계측을 이용한 휠로더 구동토크의 주요인 분석)

  • Kang, Byung-Ik;Dong, Hong-Il;Kim, Byung-Ki;Choi, Yong-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.24-29
    • /
    • 2020
  • Measuring the torque of the wheel loader of a driving device is a preemptive task to ensure its performance. In this study, wireless torque measurements were successfully conducted. Moreover, based on the experimental results and the adopted design method, the key factor of torque generation, which is the main load in driving devices, was analyzed. Other data not analyzed in this paper will be the basis for the logical design of wheel loader-based driving devices.