• Title/Summary/Keyword: safety barrier

Search Result 424, Processing Time 0.03 seconds

Aerodynamic performance of a novel wind barrier for train-bridge system

  • He, Xuhui;Shi, Kang;Wu, Teng;Zou, Yunfeng;Wang, Hanfeng;Qin, Hongxi
    • Wind and Structures
    • /
    • v.23 no.3
    • /
    • pp.171-189
    • /
    • 2016
  • An adjustable, louver-type wind barrier was introduced in this study for improving the running safety and ride comfort of train on the bridge under the undesirable wind environment. The aerodynamic characteristics of both train and bridge due to this novel wind barrier was systematically investigated based on the wind tunnel tests. It is suggested that rotation angles of the adjustable blade of the louver-type wind barrier should be controlled within $90^{\circ}$ to achieve an effective solution in terms of the overall aerodynamic performance of the train. Compared to the traditional grid-type wind barrier, the louver-type wind barrier generally presents better aerodynamic performance. Specifically, the larger decrease of the lift force and overturn moment of the train and the smaller increase of the drag force and torsional moment of the bridge resulting from the louver-type wind barrier were highlighted. Finally, the computational fluid dynamics (CFD) technique was applied to explore the underlying mechanism of aerodynamic control using the proposed wind barrier.

Preliminary Review on Function, Needs and Approach of Underground Research Laboratory for Deep Geological Disposal of Spent Nuclear Fuel in Korea (사용후핵연료 심층처분을 위한 지하연구시설(URL)의 필요성 및 접근 방안)

  • Bae, Dae-Seok;Koh, Yong-Kwon;Lee, Sang-Jin;Kim, Hyunjoo;Choi, Byong-Il
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.2
    • /
    • pp.157-178
    • /
    • 2013
  • This study gives a conceptual and basic direction to develop a URL (underground research laboratory) program for establishing the performance and safety of a deep geological disposal system in Korea. The concept of deep geological disposal is one of the preferred methodologies for the final disposal of spent nuclear fuel (SNF). Advanced countries with radioactive waste disposal have developed their own disposal concepts reasonable to their social and environmental conditions and applied to their commercial projects. Deep geological disposal system is a multi-barrier system generally consisting of an engineered barrier and natural barrier. A disposal facility and its host environment can be relied on a necessary containment and isolation over timescales envisaged as several to tens of thousands of years. A disposal system is not allowed in the commercial stage of the disposal program without a validation and demonstration of the performance and safety of the system. All issues confirming performance and safety of a disposal system include investigation, analysis, assessment, design, construction, operation and closure from planning to closure of the deep geological repository. Advanced countries perform RD&D (research, development & demonstration) programs to validate the performance and safety of a disposal system using a URL facility located at the preferred rock area within their own territories. The results and processes from the URL program contribute to construct technical criteria and guidelines for site selection as well as suitability and safety assessment of the final disposal site. Furthermore, the URL program also plays a decisive role in promoting scientific understanding of the deep geological disposal system for stakeholders, such as the public, regulator, and experts.

An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires (랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구)

  • Park, Moon-Woo;Hong, Sung-Ho;Choi, Ki-Ok;Choi, Don-Mook;Kim, Soo-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.

Impact Conditions of Performance Evaluation, and Development of High-Performance Roadside Barrier for Longitudinal Barriers in Smart Highway (스마트하이웨이 종방향 베리어 성능평가 충돌조건과 고성능 노측용 베리어 개발)

  • Kim, Dong-Seong;Kim, Kee-Dong;Ko, Man-Gi;Jang, Dae-Young
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.2
    • /
    • pp.59-67
    • /
    • 2011
  • To minimize the degree of damage in the SMART highway's punctuality and safety occurred from the car-barrier collisions, the impact conditions for longitudinal barriers in SMART highway was determined to be significantly larger than the existing maximum impact conditions. Results from computer simulation runs show that the existing domestic highest-performance roadside barrier did not satisfy the suggested impact conditions. The newly developed N-class barrier designed with computer simulation model and verified by full-scale crash tests has satisfied the SMART highway impact conditions in terms of occupant safety indexes and structural adequacy.

Study on Quality Criteria for Transparent Soundproof Panels(1) - Evaluation of Mechanical Performance and Safety (투명방음판의 품질기준 설정에 관한 연구(1) - 기계적 특성 및 안전성 평가)

  • Chang, Tae-Sun;Kim, Chul-Hwan;Hwang, Cheol-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.755-761
    • /
    • 2009
  • The major advantage of transparent materials over traditional materials in noise barriers is aesthetics. The transparent panel materials such as clear plastic or glass are an ideal way of reducing or virtually eliminating the visual impact of a noise barrier. With the use of transparent materials, the drivers' view of the roadside and the sunlight penetration to the highway would not be blocked. With the use of transparent materials, the highway and barrier appear less imposing. Korean Industrial Standards for soundproof panels have been established. But, transparent soundproof panels are not included in this standards. And, some specifications provide only a few basic characteristics for transparent soundproof panels. To develop guidelines on quality criteria for transparent soundproof panel, their mechanical properties such as wind load resistance, safety under impact, and abrasion resistance were experimentally investigated.

  • PDF

A Study on the Concept of Architectural Planning in Consideration of People with Disabilities (장애인 편의시설을 고려한 보편적 건축계획의 기본개념에 관한 연구)

  • Seong, Ki Chang;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.9 no.2
    • /
    • pp.43-50
    • /
    • 2003
  • This paper try to provide basic and universal concept of the architectural planning for the barrier-free environment. To accomplish this purpose this study has analyzed inductively the architectural requirements for all kinds of people with disabilities. The Analysis showed a safety, an accessibility and a distinguishment as the concept of architectural planning for the people with disabilities. Based on the findings of the study have been researched the general cases done for the barrier-free architectural environment. As the result, it has been proved that the design concept for the disabled person should be regarded as the basic concept of the general architectural planning.

  • PDF

Performance Evaluation of Composite Safety Barrier for Bridge by Vehicle Impact Simulation (차량 충격 시뮬레이션을 통한 복합소재 교량용 방호울타리의 성능 분석)

  • Kim, Seung-Eock;Jeon, Shin-Youl;Hong, Kab-Eui;Lee, Min-Chul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.499-506
    • /
    • 2011
  • In this study, the performance of composite safety barriers was evaluated through computer simulation. A composite safety barrier of SB4 grade was modeled. The MAT58 material model provided by LS-DYNA software was used to model composite material. The performance of composite material varies according to fiber, resin type, and fiber direction. Polyurethane resin and glass fiber were used. The performance of three different stacking designs was evaluated by carrying out vehicle impact simulation. The performance evaluation based on the vehicle crash manual includes the structural strength performance, the passenger protection performance, the vehicle behavior after crash, scattering of the guardrail. As the result of the finite element analysis, the barrier composed of the more transverse direction fibers shows the better performance on the impact simulation.

Development of the Accessibility Guidelines for Mobility Handicapped Persons in Passenger Ship

  • Kim, Hongtae;Lee, Jong-Gap
    • Journal of Navigation and Port Research
    • /
    • v.36 no.9
    • /
    • pp.763-767
    • /
    • 2012
  • The ratio of the mobility handicapped person is about 25.8% of the total population in Korea(MCT, 2006). In order to prepare for the enforcement of the "Transportation Services Improvement Act for the Mobility Handicapped People"(MCT, 2006), various equipments and installations should be developed to ensure appropriate safety level for the mobility handicapped persons in maritime transportation. While approximately 10 million people are using domestic passenger vessels annually, preferences for maritime transport is very low, especially for the mobility handicapped. This study reviewed a current status of the mobility handicapped person in domestic passenger ship and analysed the improvement plan for them. To investigate the current status of domestic passenger vessel usage by the mobility handicapped, to analysis the requirements for amenities necessary for the mobility handicapped and select the ones to be developed based on the investigated results and to do feasibility study of barrier-free ship.

Planning for Safely Control on Hazardous Material Distribution Depot.

  • Roh, S.K.;Jun, S.W.;Kang, T.H.;Seo, Y.M.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.260-268
    • /
    • 1997
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation In the safety structure and neighbouring human activity required to be estimated to find the gap between existing controls on such storage. To this content the paper discuss the issues on the approach In the blast wave barrier and safety separation distances.

  • PDF