• Title/Summary/Keyword: safe depth

Search Result 324, Processing Time 0.026 seconds

Safe Needling Depth of Pungbu(GV16) with MRI-a Retrospective Study (MRI를 통한 풍부혈(GV16)의 안전 자침 깊이에 대한 연구)

  • Yang, Hyun Jung;Park, Hae In;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Objectives : The purpose of this study is to determine the safe needling depth of Pungbu($GV_{16}$) retrospectively by using magnetic resonance imaging (MRI). Methods : We chose 114 Brain or C-spine MRI images from the Sang-Ji hospital picture archiving communication system. We measured the shortest distance from skin to cerebral dura mater passing by posterior edge of the foramen magnum on the sagittal view for the depth of Pungbu. We analyzed the differences between male and female measured values by using a student t-test. Results : The average depth of male insertion was $49.71{\pm}6.32mm$ and the shortest depth of insertion was 36.29 mm. The average depth of female insertion was $39.84{\pm}5.25mm$ and the shortest depth of insertion was 30.02 mm. The results showed a significant difference according to gender (p=0.00). Conclusions : The depth of male insertion is deeper than that of female, and the safe needling depth in the case of males is 36.29-67.35 mm, while the safe needling depth in the of females is 30.02-52.18 mm.

Review on Intraperitoneal Acupuncture and Needling Depth (복강내침술과 관련 혈위의 자침 깊이에 대한 고찰)

  • Soyeon Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.3
    • /
    • pp.55-61
    • /
    • 2023
  • Objectives : To review the needling depth, therapeutic and adverse effects of intraperitoneal acupuncture and related acupoints. Methods : Studies and reports from the literature, Korean medical health insurance data and databases were searched and selected. Results : The depth of needle insertion for acupoints related to intraperitoneal acupuncture has been documented to range from 0.9 to 10.5 cm depending on the acupoints and literature. In studies of safe needling depth, the justice of safe needling depth varied from study to study, but was generally based on the peritoneum, and the depth varies by patient age, sex, body type, and weight. Clinical studies in China have shown good efficacy and no side effects of abdominal long needle acupuncture, but there have been case reports of adverse events following abdominal acupuncture. Conclusions : To ensure both therapeutic effectiveness and safety of intraperitoneal acupuncture, It is necessary to utilize the ultrasound in clinical practice and conduct related research.

Needling Depth of Cheonchu(ST25) with Computed Tomography: a Retrospective Study (Computed Tomography를 통한 천추(ST25)의 자침 깊이에 대한 후향적 연구)

  • Park, Hae In;Yang, Hyun Jung;Park, Sang Kyun;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.61-67
    • /
    • 2015
  • Objectives : The aim of this study is to investigate the safe needling depth of Cheonchu($ST_{25}$) retrospectively by using an abdomen abdomen computed tomography(CT), and to analyze the correlation between needling depth and the characteristics of the subjects. Methods : We marked spots 50 mm away from both sides of the umbilicus in the abdomen CT and measured the vertical distance to the parietal peritoneum from the skin surface as well as waist circumference. Correlations between measured depth of Cheonchu($ST_{25}$) and variables such as age, gender and waist circumference were analyzed. Results : Average depth of the Cheonchu(n = 90) was $3.21{\pm}0.87cm$, the minimum was 1.31 cm and the maximum was 5.63 cm. A definite positive correlation was noted between needling depth and waist circumference and a significant difference was observed in needling depth according to waist circumference groups. Conclusions : Needling depth of Cheonchu($ST_{25}$) varied depending on the patient's waist circumference; safe needling depth of Cheonchu($ST_{25}$) measured by abdomen CT is 1.31~5.63 cm.

Using Ultrasonography Measurements to Determine the Depth of the GB 21 Acupoint to Prevent Pneumothorax

  • Chen, Hsiao-Neng;Chang, Chau-Yi;Chen, Lian-Zen;Chang, Yu-Jun;Lin, Jaung-Geng
    • Journal of Acupuncture & Meridian Studies
    • /
    • v.11 no.6
    • /
    • pp.355-360
    • /
    • 2018
  • Introductions: Pneumothorax is the most frequent severe acupuncture-related adverse event occurring at the GB 21 acupoint. This study used ultrasonography (US) to measure the depth of the GB 21 acupoint in adults and assessed its applicability for ensuring safe acupuncture practices. Materials and methods: A US probe was used to measure the vertical depth from the skin to the pleural line of the apex of the lungs at the right and left GB 21 acupoints. The sex, age, body weight, height, and body mass index of each person were recorded. Student t test and generalized estimating equations were used for statistical analysis. Results: Sixty women and 41 men with a median age of 29 years were included in this study. The depth of GB 21 increased with body weight, height, and body mass index (p < 0.001). The mean depth of GB 21 in men (17.4 mm) was greater than that in women (14.6 mm; p < 0.001). The depth difference between the right and left shoulders was significant in men (p < 0.001) but not in women. Conclusions: US can be used to measure GB 21 acupoint depth. Further control studies on its use to ensure safe clinical practices, including preventing acupuncture-related pneumothorax, are warranted.

Test for Concrete Crack Depth Measurement Using Ultrasonic Pulsevelocity Technique (초음파 속도를 이용한 콘크리트의 균열깊이 측정)

  • 이장화;김성욱;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.04a
    • /
    • pp.117-120
    • /
    • 1991
  • Cracks of concrete structure must be analyzed and estimated synthetically in order to have a maintenance and to insure the safety and the durability of structure. Concrete cracks have to be surveyed with respect to depth, width, shape and direction etc, but crack depth among these items is not measured easily. Occasionally, it needs to measure the crack depth of concrete structure for the purpose of evaulating the safe capacity and the necessity of repair. Therefore, this research is performed to verify the applicability and the accuracy of Ultra-sonic Pulse Velocity Technique(Tester), in non-destructive testing methods of concrete crack depth.

  • PDF

Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel (리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

Optimization of fairway design parameters: Systematic approach to manoeuvring safety

  • Gucma, Stanislaw;Zalewski, Pawel
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.129-145
    • /
    • 2020
  • The article presents a systematic approach to design of marine navigation channels parameters resulting from manoeuvring and operational safety. Relations between the parameters of waterway system elements and the conditions of safe ship operation have been determined and the objective function of waterway parameters' optimization problems has been minimized with respect to variables of construction and operation costs. These costs have been functionally associated to variables of channel width at the bottom and fairway depth. The method of fairway's width computation at specified safe depth at the preliminary and detailed stages of waterway design has been proposed. The results of this method application have been illustrated with two examples: 1. The modernization of Szczecin-Swinoujscie fairway aimed at accepting vessels of 60,000 DWT capacity. 2. Construction of an approach channel leading to a newly built container terminal in Swinoujscie harbour (Poland), handling ocean-going container ships of 20,000 TEU capacity.

Obstacle Avoidance Method for UAVs using Polar Grid

  • Pant, Sudarshan;Lee, Sangdon
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.1088-1098
    • /
    • 2020
  • This paper proposes an obstacle avoidance method using a depth polar grid. Depth information is a crucial factor for determining the safe path for collision-free navigation of unmanned aerial vehicles (UAVs) as it can perceive the distance to the obstacles effectively. However, the existing depth-camera-based approaches for obstacle avoidance require computational y expensive path planning algorithms. We propose a simple navigation method using the polar-grid of the depth information obtained from the camera with narrow field-of-view(FOV). The effectiveness of the approach was validated by a series of experiments using software-in-the-loop simulation in a realistic outdoor environment. The experimental results show that the proposed approach successfully avoids obstacles using a single depth camera with limited FOV.

Qualitative Study for Medication Use among the Hearing Impaired in Korea (국내 청각장애인의 의약품 안전사용 실태에 대한 심층면접조사)

  • Kim, Hyero;Koo, Heejo;Oh, Jung Mi;Han, Euna
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.3
    • /
    • pp.178-185
    • /
    • 2017
  • Objective: Because of communication difficulties, the hearing-impaired face many disadvantages throughout their lives. One of those is limited access to health care services, particularly medication service. Though they suffer from problems related to taking medication properly, there have been few studies on their actual condition of medication use in Korea. This study is to investigate any obstacles to properly taking medications and, therefore, to suggest preliminary evidence for policy measures to improve safe medication use among the hearing-impaired. Methods: Study participants consisted of hearing-impaired individuals living in Seoul. We also interviewed two sign language interpreters in order to illuminate health care state of the hearing-impaired. In-depth interview for each study participant was recorded and was translated into a written script for analysis. Results: Study participants were comprised of four women (66.6%) and two men (33.3%). There were one participants in 20's, two participants in 30's, one 40's, and two 50's. Sign language interpreters were all women. One was in her 30's and the other was in her 40's. Communication difficulties have been found to be key barrier to use medication safely. A negative image of pharmacists also hinders safe medication usage, lowering access to local pharmacy and leading discretional self-medication. This article provides pharmacists with solutions to promote adherence in this population. Conclusion: The hearing-impaired had limited access to medication-related information as well as using services in a hospital and local pharmacy due to their disability. Institutional improvement for safe medication usage among the hearing-impaired is necessary.

Evaluation of Pressure-Temperature Limit Curve for the Safe Operation of an RFV based on 3-D Finite Element Analyses (유한요소해석을 이용한 원자로용기 압력-온도 한계곡선의 평가)

  • Lee, Taek-Jin;Park, Yun-Won;Lee, Jin-Ho;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1567-1574
    • /
    • 2001
  • In order to operate an RPV safely it is necessary to keep the pressure-temperature (P-T) limit during the heatup and cooldown process. While the ASME Code provides the P-T limit curve for safe operation, this limit curve has been prepared under conservative assumptions In this paper the effects of conservative assumptions involved in the P-T limit curve specified in the ASME Code Sec. XI were investigated. Three different parameters the crack depth the cladding thickness and the cooling rate, were reviewed based on 3-D finite element analyses. Also the constraint effect on P-T limit curve generation was investigated based on J- T approach. It was shown that the crack depth and the constraint effect change the safe region in P-T limit curve significantly Therefore it is recommended to prepare a more precise P-T limit curve based on finite element analysis to obtain P-T limit for safe operation of an RPV.