• Title/Summary/Keyword: s correlation coefficients

Search Result 2,147, Processing Time 0.027 seconds

P-value calculation methods for semi-partial correlation coefficients

  • Kim, Seongho
    • Communications for Statistical Applications and Methods
    • /
    • v.29 no.3
    • /
    • pp.397-402
    • /
    • 2022
  • The mathematical expression of the p-value calculation for the semi-partial correlation coefficient differs between Kim (2015) and Cohen et al. (2003). These two expressions were compared and the advantages of Kim (2015)'s approach over Cohen et al. (2003) were discussed.

Evaporating heat transfer characteristics of R-22 in small diameter tubes (세관 내 R-22 의 증발 전열 특성에 관한 연구)

  • 최영석
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.134-139
    • /
    • 2000
  • Evaporating heat transfer characteristics of R-22 were measured inside smooth horizontal copper tubes with inner diameters of 3.36 mm and 5.35 mm respectively. The experiments were conducted in the closed loop which was driven by a magnetic gear pump. Experiments were performed for the following range of variables ; mass velocity of refrigerants (200 to 400 $kg/m^2$ .s) saturation temperature ($0^{\circ}C, \; 5^{\circC$}) and quality (0 to 1.0) The main results obtained are as follows : Evaporating heat transfer coefficients in the small diameter tubes (ID<7 mm) were observed to be strongly affected by a variety of diameters and to differ from those in the large diameter tubes. The heat transfer coefficients of the small diameter tubes are higher than those of the large diameter tubes. Comparing the heat transfer coefficients between experimental results and some well-known previous predictions (Shah's correlation Gungor-Winterton's and Kandlikar's correlation) it was very difficult to apply those to small diameter tubes.

  • PDF

Pool Boiling Heat Transfer Coefficients Upto Critical Heat flux (임계 열유속 근방까지의 풀 비등 열전달계수)

  • Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.571-580
    • /
    • 2008
  • In this work, pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal smooth square surface of 9.52 mm length. Tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from $10\;kW/m^2$ to critical heat flux of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and by thermocouples in the liquid pool. Test results show that pool boiling HTCs of refrigerants increase as the heat flux and vapor pressure increase. This typical trend is maintained even at high heat fluxes above $200\;kW/m^2$. Zuber's prediction equation for critical heat flux is quite accurate showing a maximum deviation of 21% for all refrigerants tested. For all refrigerant data up to the critical heat flux, Stephan and Abdelsalam's well known correlation underpredicted the data with an average deviation of 21.3% while Cooper's correlation overpredicted the data with an average deviation of 14.2%. On the other hand, Gorenflo's and lung et al.'s correlation showed only 5.8% and 6.4% deviations respectively in the entire nucleate boiling range.

Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube (순수 및 혼합냉매의 원관내 증발열전달 실험)

  • Sin, Ji-Yeong;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

Diffusion Coefficients of CdSe/CdS Quantum Rods in Water Measured Using Polarized Fluorescence Correlation Spectroscopy

  • Lee, Jaeran;Pack, Chan-Gi;Kim, Soo Yong;Kim, Sok Won
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.598-604
    • /
    • 2014
  • A polarization fluorescence correlation spectroscopy system based on a confocal microscope was built to study the rotational and translational diffusion of CdSe/CdS quantum rods (Q-rods), with the same and different polarization states between the polarizer and the analyzer (i.e. the XXX and XYY states). The rotational diffusion amplitude showed the dependences on polarization of $0.75{\pm}0.05$ in the XXX state and $0.26{\pm}0.03$ in the XYY state, when the translational diffusion amplitude was 1. The diffusion coefficients of the Q-rods were found based on their translational and rotational diffusion times in the two polarization states, in solutions with viscosity ranging from 0.9 to 6.9 cP. The translational and rotational diffusion coefficients ranged from $1.5{\times}10^{-11}$ to $2.6{\times}10^{-12}m^2s^{-1}$ and from $2.9{\times}10^5$ to $5.6{\times}10^4s^{-1}$, respectively.

The study of caries activity test by multiplex-quantity real time PCR with easy perio test (구강세균 유전자 검사(easy perio test)법을 이용한 치아우식 검사)

  • Yun, Han Gyeol;Park, Seong Gyu;Kim, Jin
    • Journal of Korean Academy of Dental Administration
    • /
    • v.6 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • The aim of this study was to evaluate the competency of the Easyperio test, a genetic test method based on real time PCR for the detection of bacteria that cause dental caries and periodontal disease. To verify the validity of this text, various dental health evaluations were administered to 33 boys between the ages of 12 to 14, as this age group commonly experiences dental caries. These evaluations included a dental caries experience survey, a first molar health evaluation, the Dentocult Streptococcus mutans (SM) strip mutans, the Dentocult Lactobacillus spp (LB) test, and the Easyperio test. The correlation coefficients between the level of the Dentocult SM strip mutans and the dental caries experience were DT (R=0.570, p=0.001), DMFT (R=0.376, p=0.031), and first molar health (R=-0.395, p=0.023). The correlation coefficients between the amount of SM in the Easyperio test and dental caries experience were DT (R=0.528, p=0.002), DMFT (R=0.369, p=0.035), and first molar health (R=-0.426, p=0.013). The correlation coefficients between the level of the dentocult SM strip mutans and the SM amounts of the Easyperio test were S.mi (R=0.564 p=0.001) and S.mu (R=0.621, p=0.002). The correlation coefficients between the level of the Dentocult LB test and the SM amount of Easyperio test was S.mi (R=0.495, p=0.003). In conclusion, Easyperio test may be an easy and effective method for the differentiation and diagnosis of dental caries through quantitative and qualitative analysis of oral bacteria.

A Study on Correlation among Length Changes of Body Surface Total lines and Segment Lines -Changed Amount Caused by the Lower Limb Movements- (체표(體表)길이 변화(變化)의 상관성(相關性) 연구(硏究) - 다리(下肢) 동작(動作)에 따른 변화량(變化量)을 중심(中心)으로 -)

  • Cho, Sung Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.4
    • /
    • pp.622-637
    • /
    • 1993
  • The Purposes of this study were to investigate the significant correlation among the length changes of body surface total lines and between the length changes of body surface total lines and those of component body surface segment lines, and to reveal anticipated relation among body surface length changes by the lower limb movement including all movement direction of hip joint, knee joint & ankle joint for the more functional clothing making & designing. 10 Crosswise & 5 lengthwise body surface total lines and 48 crosswise & 39 lengthwise body surface segment lines of 26 female college students aged from 18 to 24 years were measured directly on the body surface and analyzed by ANOYA & Multiple Comparison Test(Tukey), and the length changes of them were calculated as the difference of the mean length at Fl movement from the mean length at each movement and were analyzed by PEARSON CORRELATION. The results were as following : 1. Correlation among the length changes of body surface total lines (1) Correlation among the length changes of body surface total lines significantly changed by the movement ; 1) The more GA5 expanded, the more GA6 & GA7 each expanded, and the more GA18 expanded, the more GA1 & GA3 each expanded. 2) The more GA15 expanded, the less GA14 each contracted. 3) The more GA7 expanded, the larger GA17 contracted. 4) The more GA1 & GA18 expanded, the larger GA16 contracted, and the larger GM contracted, the less GA16 contracted. (2) Only GA7 and GA17(at F4) showed high (over r=0.7) correlation coefficient, But others' correlation coefficients were r=0.4~0.7. (3) Correlation coefficients among & between girth items and length items 1) Correlation coefficients among girth items were shown + ; between GA3 and GA4, GA5, GA8, between GA5 and GA6, GA7, GA9 each, between GA1 and GA6 and between GA4 and GA7. 2) Correlation coefficients among length items were shown + or - ; shown + between GA14 and GA15 and between GA17 and GA16 ; but Shown - Between GAlS and GA16. 3) Correlation coefficients between girth items and length items were mainly shown - : shown-between GA1 and GA16, GA17, between, GA4 and GA16, between GA6, GA7 each and GA17, between GA8 and GA18 ; but shown + between GA1, GA3 each and GA18 and between GA8 and GA14 were shown +. 2. Correlation between the length changes of body surface total lines and those of component body surface segment lines. (1) All correlation coefficients were + except A147 of GA14. (2) Correlation coefficient over r=0.7 was shown ; between GA3 and CB3, A35 each, between GA5 and A054, between GA6 and A63, between GA7 and A72, A74 each, between GA8 and A83, A84 each, between GA15 and A153, between GA16 and Al64, Al65 each, between GA18 and A189 : but was not shown between GA4, GA17 and it's component body surface segment lines each. (3) Characteristics of correlation between the length changes of body surface total lines and those of body surface segment lines ; 1) If significant correlation of body surface total lines were expansion parts, it's component body surface segment lines was also expansion segment and the otherwise were the same. But exception was shown between expansion line GA3 and A031 (at F4), between GA18 and AlS9 (at F6) and between GA14 and A147, so to speak GA3 & lines and GA14 was contraction total line oppositely A147 was expansion. 2) The more GA3, GAlS expanded, the less A031, A189 contracted. 3) The more GA14 contracted, the more A147 expanded. 4) All correlation except the above 2), 3), the more total lines (GA1, GA3, GA5, GA15, GA16, GA18) expanded, the more segment lines (A15, CB1, A31, A34, CB3, A52, A54, A153, A169, A181) expanded, or the larger total lines (GA14, GA16, GA17) contracted, the larger segment lines (A141, A142, A161, A164, A165, A172) contracted.

  • PDF

Test of the Korean Parent as a Teacher (KPAAT) Inventory - Focusing on the Parents of Preschoolers - (한국형 교사로서의 부모 양육태도 검사도구 검증 - 학령전기 아동의 부모를 대상으로 -)

  • Kim, Young Hee;Kim, Kae Sook;Kim, Shin-Jeong
    • Child Health Nursing Research
    • /
    • v.15 no.3
    • /
    • pp.314-324
    • /
    • 2009
  • Purpose: This study was done to test the reliability and validity of the Korean parent as a teacher (KPAAT) inventory for a group of parents of preschoolers. Methods: For this methodological study with 187parents were recruited from October to December, 2004 using convenience sampling. Self-report questionnaires measured level of child-rearing attitude. Internal consistency reliability was assessed with Cronbach's alpha coefficients. Construct validity of KPAAT inventory was analyzed using item analyses and factor analysis. Statistical analysis was done using SPSS Program Version 14.0. Results: The Cronbach's alpha coefficient for the KPAAT inventory was 0.881. For item analyses, inter-item correlation coefficients were -0.029${\sim}$0.781. Corrected item-total correlation coefficients were 0.012-0.737. Item-to"subscale correlation coefficients ranged from 0.509 to 0.817. Subscale-to-total correlation coefficients were 0.965, 0.711, respectively. Orthogonal varimax rotation of the 85 items in 16 areas of the KPAAT inventory, showed two factors, positive parenting attitude and negative parenting attitude. These two factors explained 48.2% of the total variance. Conclusion: In the original KPAAT inventory six factors were identified through factor analysis, however, in this study only two factors were extracted. Whereas, internal consistency reliability was within an acceptable range, these results suggest additional studies are needed to improve the validity of the KPAAT inventory.

  • PDF

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

Image Processing System for Measuring the Chromatophore Pollution Solution of and Animal Slurry Using Optical-Density (가축분뇨수의 색소오염물질 분해과정 측정 영상처리 시스템)

  • 이대원;김현태;김용석;민병로;이강춘;박은석;한정환;이수희;김정동
    • Journal of Animal Environmental Science
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 2001
  • This study conducted to monitor decomposition process of the charomatophore pollution solution of an animal slurry by using a CCD camera. After the solution was put into test tube, the images(R, G, B, H, L, S) values of the solution were measured by the imgae processing system, and those of it\`s optical density were measured for three hours to be decomposed by microscopic organism. The values of measured for three hours to be decomposed by microscopic organism. The values of measured images(R, G, B, H, L, S) were analysed and compared with those of the optical density. Some of the results are as follows. 1. High correlation coefficients, which analyzed by using data on linear equations, were 0.9557 and 0.9672. They were decreased regularly in this R-value experiment of RGB level. The microscopic organism in this experiment was effective for decomposition of the red charomatophore pollution solution. 2. The values of all correlation coefficients from relationship between RGB-value and optical density were more than 0.95 except H-values. RGB-values, which were average values of summed R, G, B values, had correlation coefficients of 0.9863, 0.9937. These results showed so good relationship that decomposition process of charomatophore pollution solution could be monitored by a image processing system.

  • PDF