• Title/Summary/Keyword: run-by-run control

Search Result 633, Processing Time 0.021 seconds

Development in Equipment of Low Point Marking Machine Control System (Low Point 모니터링 장비의 개발)

  • Choi, Myung-Hwan;Kim, Won-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.4
    • /
    • pp.205-209
    • /
    • 2010
  • Even the domestically small-and medium-sized companies progressed development in the monitoring equipment of inspecting run out in steel wheel aiming to supply and generalize through developing the monitoring equipment for securing quality technology and enhancing quality-test level. Run-Out value in vehicle wheel was measured with Computer & Servo system by using Low-Point marking machine control system, which is this development product. Low-Point value was operated and calculated. It marked by revolving wheel as much as the demanded measurement value based on 1ST harmony curve. Thus, the shipment of inferior product, which occurs in the measurement by the existing worker, could be blocked in advance. In the existing case, 60 sec. was required for inspecting 1 product. However, it came to bring about a rise in production volume through shortening inspection time to 8 seconds and improving workers' operating environment.

  • PDF

A Design and Implementation of Run-time Support System for Concurrent Processing of the CHILL (CHILL 언어의 병행처리를 위한 Run-time 지원 시스템의 설계 및 구현)

  • Ha, Su-Cheol;Jo, Cheol-Hoe
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.7
    • /
    • pp.1941-1954
    • /
    • 1999
  • This paper presents a design and implementation of CRs(CHILL Run-time support System) to adapt the concurrent processing facilities of CHILL(CCITT High Level Language) which had recommended by ITU-T(International Telecommunication Union Telecommunication Standardization Sector). Because the CHILL provides more various concurrent processing facilities that other concurrent programming language, a design and implementation on CRS can give us real effects to gain the major functionalities and the techniques of the concurrent processing. In this paper, we design the interface rules of concurrent functions to conform with the CHILL compiler. We use the concurrent processing primitives as the library style to be invoked by procedure calls, and implement the start-up routine of the CHILL program, the context switching routine, and the CHILL process control parts to control be execution of the CHILL processes concurrently.

  • PDF

런규칙을 사용한 개량된 경계선 수정계획의 설계와 Markov 연쇄의 적용

  • 박창순
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2004.04a
    • /
    • pp.413-418
    • /
    • 2004
  • The bounded adjustment is known to be more efficient than repeated adjustment when the cost is incurred for engineering process control. The procedure of the bounded adjustment is to adjust the process when the one-step predicted deviation exceeds the adjustment limit by the amount of the prediction. In this paper, two run rules are proposed and studied in order to improve the efficiency of the traditional bounded adjustment procedure. The efficiency is studied in terms of the standardized cost through Monte Carlo simulation when the procedure is operated with and without the run rules. The adjustment procedure operated with run rules turns out to be more robust for changes in the process and cost parameters. The Markov chain approach for calculating the properties of the run rules is also studied.

  • PDF

Studies on the Comparison of Scutellaria Radix Analyses by CE and HPLC (모세관전기영동장치 및 고속액체 크라마토그래피에 의한 황금의 성분 분석법 비교)

  • 면노홍;김효진
    • YAKHAK HOEJI
    • /
    • v.43 no.4
    • /
    • pp.429-436
    • /
    • 1999
  • A simple, accurate and reproducible Capillary electrophoresis (CE) assay has been developed for the determination of baicalin, baicalein, wogonin and chrysin in Scutellaria baicalensis. Successful separation of these compounds has been obtained in 35 mM phosphate butter (pH 7.0) using a untreated fused silica capillary ($57{\;}cm{\times}75{\;}{\mutextrm{m}}$ i.d.) at $25^{\circ}C$ with the electric field of 19kV. Baicalin, baicalein wogonin and chrysin was separated and detected at 280 nm 13 min. The detection limits of CE were acceptable compared to HPLC. Reproducibilities of migration time and peak area were 0.66~1.11% (within-run), 2.18~3.38% (between-run) and 3.50~4.55% (within-run), 3.97~4.82%(between-run) at CE. The results indicate that CE could be a promising technique for quality and quantity control analysis of Scutellaria baicalensis as a validation method.

  • PDF

A Study on Volume Reduction of Waste Sludge by Aerobic Thermophilic Bacteria (호기성 호열미생물에 의한 하수슬러지 감량화 효율에 관한 연구)

  • Bae, Yoon-Sun;Kim, Soon-Young;Nam, Duck-Hyun;Park, Chul-Hwi;Kim, Jin-Su;Takada, Kazu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.497-505
    • /
    • 2005
  • Domestic Sewage Treatment Plants are mostly based on biological treatment, in which large amounts of excess sludge are generated and occupy about 40 ~ 60% of the total sewage treatment costs. Several methods for sludge treatment has been so far reported as upgrading biodegradation of sludge; heat treatment, chemical treatment, including thermo-alkali and ozone, mechanical treatment including ultrasonic pulverization. But, it has a limitation in case of reducing the amount of excess sludge which are already producted. In this study, application of excess sludge reduction process using thermophilic aerobic bacteria for activated sludge was examined. The research was carried out two different stage. one for a biological wastewater treatment and the other for a thermophilic aerobic solubilization of the waste sludge. A portion of excess sludge from the wastewater treatment step was into the thermophilic aerobic sludge solubilization reactor, in which the injected sludge was solubilized by thermophilic aerobic bacteria. The solubilized sludge was returned to the aeration tank in the wastewater treatment step for its further degradation. Sludge solubilization reactor was operated at $63{\pm}2^{\circ}C$ with hydraulic retention time(HRT) of 1.5 ~ 1.7 day. Control group was operated with activated sludge process(AS) and experiment group was operated with three conditions(RUN 1, RUN 2, RUN3). RUN 1 was operated with AS without sludge solubilization reactor. RUN 2 were operated with AS with sludge solubilization reactor to examine correlation between sludge circulation ratio and sludge reduction ratio by setting up sludge circulation ratio to 3. RUN 3 was operated with sludge circulation ratio of 3 and MLSS concentration of 1,700~2,000mg/L to examine optimum operation condition. The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge solubilization ratio and sludge reduction ratio were 53. 7%, 95.2% respectively. After steady state operation, average concentration of TBOD, SBOD, $TCOD_{Cr}$, $SCOD_{Cr}$, TSS, VSS, T-N, T-P of effluent were 4.5, 1.7, 27 .8, 13.8, 8.1, 6.2, 15.1, 1.8mg/L in the control group and were 5.6, 2.0, 28.6, 19.1, 9.7, 7.2, 16.1, 2.0mg/L in the experimental group respectively. They were appropriate to effluent standard of Sewage Treatment Plants.

Control Flow Checking at Virtual Edges

  • Liu, LiPing;Ci, LinLin;Liu, Wei;Yang, Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.1
    • /
    • pp.396-413
    • /
    • 2017
  • Dynamically checking the integrity of software at run-time is always a hot and difficult spot for trusted computing. Control-flow integrity is a basic and important safety property of software integrity. Many classic and emerging security attacks who introduce illegal control-flow to applications can cause unpredictable behaviors of computer-based systems. In this paper, we present a software-based approach to checking violation of control flow integrity at run-time. This paper proposes a high-performance and low-overhead software control flow checking solution, control flow checking at virtual edges (CFCVE). CFCVE assigns a unique signature to each basic block and then inserts a virtual vertex into each edge at compile time. This together with insertion of signature updating instructions and checking instructions into corresponding vertexes and virtual vertexes. Control flow faults can be detected by comparing the run-time signature with the saved one at compile time. Our experimental results show that CFCVE incurs only 10.61% performance overhead on average for several C benchmark programs and the average undetected error rate is only 9.29%. Compared with previous techniques, CFCVE has the characteristics of both high fault coverage and low memory and performance overhead.

The Statistical Design of CV Control Charts for the Gamma Distribution Processes (감마분포 공정을 위한 변동계수 관리도의 통계적 설계)

  • Lee, Dong-Won;Paik, Jae-Won;Kang, Chang-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • Recently, the control chart is developed for monitoring processes with normal short production runs by the coefficient of variation(CV) characteristic for a normal distribution. This control chart does not work well in non-normal short production runs. And most of industrial processes are known to follow the non-normal distribution. Therefore, the control chart is required to be developed for monitoring the processes with non-normal short production runs by the CV characteristics for a non-normal distribution. In this paper, we suggest the control chart for monitoring the processes with a gamma short runs by the CV characteristics for a gamma distribution. This control chart is denoted by the gamma CV control chart. Futhermore evaluated the performance of the gamma CV control chart by average run length(ARL).

Estimating the Elasticity of Crude Oil Demand in Korea (한국 원유수요의 탄력성 추정)

  • Lee, Kyung-Hee;Kim, Kyung-Soo
    • Management & Information Systems Review
    • /
    • v.37 no.3
    • /
    • pp.65-81
    • /
    • 2018
  • This study estimated the long-run and the short-run price and income elasticity of crude oil demand by using the ARDL model in Korea. First, the long-run cointegration relationship existed between crude oil demand and price or income in the ARDL-bounds tests. Second, the long-run own price, the cross price elasticity and the income elasticity were both statistically significant elastic and sensitive in the ARDL. Third, there was autocorrelation of the residuals, but no misspecification errors and heteroscedasticity, and then the residuals showed a normal distribution. And the CUSUM & CUSUMSQ tests showed that the coefficients were stable. Fourth, the short-run own price, the cross price elasticity and the income elasticity were both statistically significant elastic and sensitive in the ARDL-RECM. The ECM with the short-run dynamics showed rapid adjustments in the long-run equilibrium of oil demand after the economic crisis. In the short-run, the sensitivity of crude oil demand to price and income changes has moved in the same direction as the long-run case. Korea, depending too much on foreign crude oil, is vulnerable to the shocks of oil prices, so rising oil prices can certainly have a negative impact on Korea's trade balance. And the elasticity of long-run oil prices may help to control and manage Korea's oil demand. The government needs to strengthen monitoring of the country's policies and market trends related to crude oil, establish strategies to customize national policies and market conditions, and strengthen active market dominance efforts through pioneering new market and diversification.

A Study of the PDCA and CAPD Economic Designs of the $\bar{x}$ Control Chart

  • Sun, Jing;Tsubaki, Michiko;Matsui, Masayuki
    • Industrial Engineering and Management Systems
    • /
    • v.6 no.1
    • /
    • pp.11-21
    • /
    • 2007
  • The PDCA (Plan, Do, Check and Act) cycle is often used in the field of quality management. Recently, business environments have become more competitive, and the due time of products has shortened. In a short production run process, to increase efficiency of management, the necessity for distinguishing the PDCA design that starts with PLAN and the CAPD design that starts with CHECK has been clarified. Starting from Duncan (1956), there have been a number of papers dealing with the economic design of control charts from the viewpoint of production run. Some authors (Gibra, 1971; Ladany and Bedi, 1976; etc.) have studied the economic design for finite-length runs; other authors (Crowder, 1992; Del Castillo and Montgomery, 1996; etc.) have studied the economic design for short runs. However, neither the PDCA nor the CAPD design of control charts has been considered. In this paper, both the PDCA and CAPD designs of the $\bar{\x}$ chart are defined based on Del Castillo and Montgomery's design (1996), and their mathematical formulations are shown. Then from an economic viewpoint, the optimal values of the sample size per each sampling, control limits width, and the sampling interval of the two designs are studied. Finally, by numerically analyzing the relations between the key parameters and the total expected cost per unit time, the comparisons between the two designs are considered in detail.

Behavior of Soluble Microbial Products by the Internal Recycle Rate in MBR Process (MBR공정에서 내부 반송비에 따른 생물대사성분의 거동)

  • Lee, Won-Bae;Cha, Gi-Cheol;Jeong, Tae-Young;Kim, Dong-Jin;Yoo, Ik-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.602-608
    • /
    • 2005
  • A laboratory-scale experiment was conducted to investigate control of soluble microbial products (SMP) by the internal recycle rate in the submerged membrane separation activated sludge process. The internal recycle rate of the reactor RUN 1 and RUN 2 were 100 % and 200 %, respectively. SMP concentration was rapidly accumulated in the reactor (RUN 1). The variation of accumulated SMP concentration was related to the denitrification rate at the beginning experiment however SMP concentration decreased without correlatively to the denitrification rate during long operation time. The microbial kinetic model was rapidly presented in the both microbial growth and extinction in the reactor (RUN 1). In the SMP kinetic model, Internal recycle rate is the lower, value of UAP and BAP which SMP matter were presented low. The study about development of kinetic model is relatively well adjusted to the experiment exception SMP. In the future, SMP formation equation must be thought that continually research is necessary.