• 제목/요약/키워드: rubber isolator

검색결과 97건 처리시간 0.031초

Silicon Matrix MRE 의 인가자기장에 따른 전단계수 증가율 측정 (Measurement of Shear Modulus Increment Ratio of Magneto-rheological Elastomer based on Silicon Matrix due to Induced Magnetic field)

  • 오재응;노정준;이선훈;김진수;정운창
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.288-291
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation) in rubber matrix. In this study, Silicon was used as a matrix in order to manufacture MREs. Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced magnetic field. As the addition of CIP and induced magnetic field intensity increased, increment of MR effect was observed.

  • PDF

면진수조의 2차원 동적 해석기법 개발 (2-D Dynamic analysis method of base-isolated pool structure)

  • 전영선;최인걸;김진웅
    • 전산구조공학
    • /
    • 제8권3호
    • /
    • pp.67-74
    • /
    • 1995
  • 본 연구에서는 면진수조의 2차원 동적 해석기법을 개발하고 축소모델을 사용한 진동대실험을 통하여 해석기법의 타당성을 검증하였다. 수조의 벽체는 집중질량을 사용하여 모델링하였으며 유체의 부가질량을 벽체의 절점에 부가함으로써 유체의 동수역학적인 영향을 고려하였다. 면진수조의 운동방정식은 벽체와 유체로 구성된 상부구조의 운동방정식과 바닥슬래브와 면진장치로 구성된 하부구조의 운동방정식을 연계하여 구하였다. 진동대 실험에서는 투명한 아크릴로 제작한 모형수조를 사용하였으며 면진장치는 4개의 고감쇠 적층 고무베어링(High Damping Laminated Rubber Bearing)을 사용하였다. 축소모델에 의한 실험결과는 대체적으로 해석결과와 잘 일치하였으며 계산결과가 다소 보수적인 것으로 나타났다.

  • PDF

Efficient optimal design of passive structural control applied to isolator design

  • Kamalzare, Mahmoud;Johnson, Erik A.;Wojtkiewicz, Steven F.
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.847-862
    • /
    • 2015
  • Typical base isolated buildings are designed so that the superstructure remains elastic in design-level earthquakes, though the isolation layer is often quite nonlinear using, e.g., hysteretic elements such as lead-rubber bearings and friction pendulum bearings. Similarly, other well-performing structural control systems keep the structure within the linear range except during the most extreme of excitations. Design optimization of these isolators or other structural control systems requires computationally-expensive response simulations of the (mostly or fully) linear structural system with the nonlinear structural control devices. Standard nonlinear structural analysis algorithms ignore the localized nature of these nonlinearities when computing responses. This paper proposes an approach for the computationally-efficient optimal design of passive isolators by extending a methodology previously developed by the authors for accelerating the response calculation of mostly linear systems with local features (linear or nonlinear, deterministic or random). The methodology is explained and applied to a numerical example of a base isolated building with a hysteretic isolation layer. The computational efficiency of the proposed approach is shown to be significant for this simple problem, and is expected to be even more dramatic for more complex systems.

선체로 전달되는 해수 이송 배관의 진동 저감 분석 (Analysis for Reducing Vibration Transmitted from the Sea-water Conveying Pipe to the Hull)

  • 한형석;정의봉;박경훈;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1177-1184
    • /
    • 2008
  • URN(underwater radiated noise) is one of the important performances of the battle ship related to the stealth. The main source of the URN is the structure-borne noise on the hull. And the pipe vibration transmitted to the hull is the main source of the structure-borne noise when the speed of the ship is lower than CIS(cavitation inception speed). In this paper, the vibration isolator(rubber mount) for the pipe system is described in order to reduce the structure-borne noise transmitted to the hull. The vibrations on the sea-water conveying pipes and their supports are measured in order to know how much vibration occurs on those positions. Based on these test results, the improved design of the rubber mount is suggested by the parametric study and is verified numerically with the pipe and hull model.

진동대 실험 및 해석을 통한 고감쇠 고무받침의 면진성능 연구 (A Study on Isolation Performance of High Damping Rubber Bearing Through Shaking Table Test and Analysis)

  • 김후승;오주
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.601-611
    • /
    • 2016
  • 최근 빈번하게 발생하는 크고 작은 지진에 대비하여 구조물의 지진에 대한 안전성을 확보하기 위한 방안으로 지진격리시스템을 이용한 연구개발과 사용이 점차 증가하고 있다. 지진격리시스템의 하나인 고감쇠 고무받침(HDRB)는 특수한 고감쇠 고무(HDR)를 이용한 적층형 고무받침으로서 유사 지진격리장치인 납 고무받침에 비해 감쇠기능이 다소 떨어지는 단점이 있어 활용도가 높지 않았다. 그러나, 고감쇠 고무받침은 재료와 형상이 유사한 천연고무받침의 비해 우수한 감쇠력을 가지고 있으며 기존 납 고무받침의 경우 납의 유해성이 문제되어 납을 사용하지 않은 고감쇠 고무받침에 대한 연구가 증가하고 있다. 본 연구에서는 고감쇠 고무받침을 대상으로 압축응력 의존성 및 주파수 의존성, 반복하중 의존성 등 다양한 특성에 대하여 실험을 실시하였다. 그리고 여러 계기지진파 상태에서 고감쇠 고무받침의 내진성능을 평가하기 위해 진동대 실험과 분석을 수행하였다. 축소교량에 고감쇠 고무받침을 적용한 모델을 사용했고, 지진격리와 비 지진격리로 구분하여 진행하였다. 그 결과 고감쇠 고무받침을 적용할 경우 비 지진격리의 경우에 비해 높은 감쇠효과를 보였으나 Mexico City와 같은 연약지반의 구조물에 지진격리를 적용할 경우 오히려 구조물의 응답이 증가하는 양상을 나타내 지진격리장치 적용성에 주의해야 할 것으로 판단된다.

PRB 지진격리장치의 성능 검증을 위한 해석 및 실험적 연구 (Study on the Performance Verification of PRB Isolation Device using Simulation and Experiment)

  • 김성조;김세윤;지용수;김봉식;한동석
    • 한국전산구조공학회논문집
    • /
    • 제33권5호
    • /
    • pp.311-318
    • /
    • 2020
  • 본 논문에서는 모듈화(Module)된 부품을 활용한 탄성받침 성능개선기법에 대하여 소개하였다. 각각의 모듈화된 장치들이 지진 강도 및 이동 변위에 따른 단계별 거동을 함으로써 받침의 성능을 개선하게 된다. 모듈화된 장치들은 초기전단저항 블럭, 완충장치, 변위수용가이드, 낙교방지블럭이 있으며, 탄성받침에 추가적으로 적용되었다. 이 장치는 지진의 규모에 따라 4단계로 거동하며, 1차로 설계변위를 수용하고, 2차, 3차에서는 대규모 지진을 수용하며, 4차로는 대규모의 지진에 대해서 낙교방지가 가능하도록 설계되어 탄성받침의 용량 제한을 증가시킨다. 본 논문에서는, 개발기술인 PRB 지진격리장치를 유한요소해석을 통해 해석하여 격리장치의 이론적인 거동이 구현되는지와, 대규모 지진에 해당하는 하중을 견딜 수 있는지 확인하였다. 그리고 이를 바탕으로 실험을 통해 성능평가를 진행하여 두 결과의 비교 분석을 통해 PRB 지진격리장치가 탄성받침의 성능을 개선할 수 있는지 검증하였다.

납적층고무받침(LRB)으로 지지된 면진 원전 구조물의 수직방향 지진응답 분석 (Analyses of Vertical Seismic Responses of Seismically Isolated Nuclear Power Plant Structures Supported by Lead Rubber Bearings)

  • 조성국;윤성민;김두기;홍기증
    • 한국지진공학회논문집
    • /
    • 제19권3호
    • /
    • pp.133-143
    • /
    • 2015
  • It is very important to assure the seismic performance of equipment as well as building structures in seismic design of nuclear power plant(NPP). Seismically isolated structures may be reviewed mainly on the horizontal seismic responses. Considering the equipment installed in the NPP, the vertical earthquake responses of the structure also should be reviewed. This study has investigated the vertical seismic demand of seismically isolated structure by lead rubber bearings(LRBs). For the numerical evaluation of seismic demand of the base isolated NPP, the Korean standard nuclear power plant (APR1400) is modeled as 4 different models, which are supported by LRBs to have 4 different horizontal target periods. Two real earthquake records and artificially generated input motions have been used as inputs for earthquake analyses. For the study, the vertical floor response spectra(FRS) were generated at the major points of the structure. As a results, the vertical seismic responses of horizontally isolated structure have largely increased due to flexibility of elastomeric isolator. The vertical stiffness of the bearings are more carefully considered in the seismic design of the base-isolated NPPs which have the various equipment inside.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

부가질량 효과에 따른 고효율 방진마운트의 진동저감 성능평가 (Evaluation of high performance isolation spring mount by attached masses)

  • 호경찬;이병철;이용현;이영제;김민배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1247-1252
    • /
    • 2007
  • The machine equipment of the building inside occurs the vibration. In order to reduce this vibration spring, rubber pad is used. But efficiency of this classical mount is restricted at specific frequency. Also maximum efficiency design is complicated. This paper proposes and examines a attached mass isolation system that is used to reduce transmitted vibrations from machines onto their floor support. With attached mass the low frequency performance is improved overall. The performance is showed in 2 degree of freedom model test. And the proposed isolator has been validated by dynamic test and good agreement between theoretical and experimental results has been obtained.

  • PDF

Magnetic Reactive Particle 코팅 및 인가전류에 따른 Magnetorheological Elastomer 의 전단계수 측정 (Experimental Evaluation on Shear Modulus of MRE due to MRP Coating and Induced Current)

  • 오재응;정운창;김진수;윤정민;노정준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.927-929
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation). Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced current. As induced magnetic field intensity increased and coated with MRP, increment of MR effect was observed.

  • PDF