Measurement of Shear Modulus Increment Ratio of Magneto-rheological Elastomer based on Silicon Matrix due to Induced Magnetic field

Silicon Matrix MRE 의 인가자기장에 따른 전단계수 증가율 측정

  • 오재응 (한양대학교 대학원 융합기계공학과) ;
  • 노정준 (한양대학교 대학원 융합기계공학과) ;
  • 이선훈 (한양대학교 대학원 융합기계공학과) ;
  • 김진수 (한양대학교 대학원 융합기계공학과) ;
  • 정운창 (한양대학교 대학원 융합기계공학과)
  • Published : 2014.10.29

Abstract

MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation) in rubber matrix. In this study, Silicon was used as a matrix in order to manufacture MREs. Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced magnetic field. As the addition of CIP and induced magnetic field intensity increased, increment of MR effect was observed.

Keywords