• Title/Summary/Keyword: rotational resistance

Search Result 106, Processing Time 0.038 seconds

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

Boundary Conditions and Fire Behavior of Concrete Filled Tubular Composite Columns

  • Rodrigues, Joao Paulo C.;Correia, Antonio J.M.;Kodur, Venkatesh
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.313-325
    • /
    • 2018
  • Concrete-filled steel tubular (CFST) members are commonly used as composite columns in modern construction. However, the current guidelines for members' fire design (EN1994-1-2) have been proved to be unsafe in case the relative slenderness is higher than 0.5. In addition, the simplified design methods of Eurocode 4 are limited to circular and square CFST columns, while in practice columns with rectangular and elliptical hollow sections are being increasingly used because of their architectural aesthetics. In the last years a large experimental research has been carried out at Coimbra University on the topic. They have been tested concrete filled circular, square, rectangular and elliptical hollow columns with restrained thermal elongation. Some parameters such as the slenderness, the type of cross-section geometry as well as the axial and rotational restraint of the surrounding structure to the column have been tested in order to evaluate their influence on the fire resistance of such columns. In this paper it is evaluated the influence of the boundary conditions (pin-ended and semi-rigid end-support conditions) on the behavior of the columns in case of fire. In these tests it could not be seen a marked effect of the tested boundary conditions but it is believed that the increasing of rotational stiffness increases the fire resistance of the columns.

Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study

  • Chen, Huizhong;Han, Bing;Xu, Tianmin
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.21-31
    • /
    • 2019
  • Objective: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. Methods: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations ($0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$, $8^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. Results: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. Conclusions: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles.

Proposal of Rotating Stability Assessment Formula for an Interlocking Caisson Breakwater Subjected to Wave Forces (파랑하중에 대한 인터로킹 케이슨 방파제의 회전 안정성 평가식 제안)

  • Park, Woo-Sun;Won, Deokhee;Seo, Jihye;Lee, Byeong Wook
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.1
    • /
    • pp.11-16
    • /
    • 2020
  • The rotational stability of an interlocking caisson breakwater was studied. Using the analytical solution for the linear wave incident to the infinite breakwater, the phase difference effect of wave pressures in the direction of the breakwater baseline is considered, and Goda's wave pressure formula in the design code is adopted to consider the nonlinearity of the design wave. The rotational safety factor of the breakwater was defined as the ratio of the rotational frictional resistance moment due to caisson's own weight and the acting rotational moment due to the horizontal and vertical wave forces. An analytical solution for the rotational center point location and the minimum safety factor is presented. Stability assessment formula were proposed to be applicable to all design wave conditions used in current port and harbor structure design such as regular waves, irregular waves and multi-directional irregular waves.

Permanent Deformation Properties of Asphalt Binder Modified by Pyrolysis Carbon Black of Waste Tires (열분해 카본블랙을 이용한 아스팔트 바인더의 소성변형 특성)

  • Lee, Dong-Hang;Kim, Jung-Ku;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.4028-4032
    • /
    • 2013
  • Recycling method for pyrolyzed carbon black from pyrolysis process of waste tires is needed. Carbon black from pyrolysis of waste tires was used to modify and improve the permanent deformation properties of asphalt binder. 0%, 5%, 10%, 15% and 20% of pyrolyzed carbon black was mixed. Couple of laboratory tests, such as softening point, flash point test, rotational viscometer test and dynamic shear rheometer test, were carried out. The use of pyrolyzed carbon black incresed the softening point, rotational viscosity at 135oC, and resistance of permanent deformation.

Design of Device for Rotator Cuff Training and Its Experimental Validation with sEMG (회전근개 훈련용 기기 설계와 sEMG를 활용한 실험적 검증)

  • Byun, Sangkyu;Kim, Jaehoon;Chung, Jiyong;Kim, Heeyoung;Shin, Sungwook;Lee, Eunghyuk
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.8
    • /
    • pp.1035-1043
    • /
    • 2021
  • The shoulder is less stable than other joints, making it easier to onset of various shoulder disorders. In addition, limited range of motion and pain in the shoulder due to shoulder disorders restricts daily life and social activities. The problem with exercise therapy can be reduced in exercise effect by causing boredom through simple repetition of motion, thus reducing the patient's willingness to participate. Therefore, this paper aims to provide a treatment method that can induce active participation of patients by developing devices capable of passive, active, and resistance exercise and serious game contents using them. Furthermore, sEMG was used to verify whether the rotational exercise in the horizontal and vertical using serious game contents helps the shoulder movement actually. The measured sEMG signal was classified as 5 phases according to the angle of rotation and calculated the mean integrated EMG. The mean integrated EMG for the experimental results was higher in all phases when rotational was performed compared to those when both horizontal and vertical rotational exercise remained initial posture, indicating an increase in muscle activity.

Study on transient performance of tilting-pad thrust bearings in nuclear pump considering fluid-structure interaction

  • Qiang Li;Bin Li;Xiuwei Li;Quntao Xie;Qinglei Liu;Weiwei Xu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2325-2334
    • /
    • 2023
  • To study the lubrication performance of tilting-pad thrust bearing (TPTBs) during start-up in nuclear pump, a hydrodynamic lubrication model of TPTBs was established based on the computational fluid dynamics (CFD) method and the fluid-structure interaction (FSI) technique. Further, a mesh motion algorithm for the transient calculation of thrust bearings was developed based on the user defined function (UDF). The result demonstrated that minimum film thickness increases first and then decreases with the rotational speed under start-up condition. The influence of pad tilt on minimum film thickness is greater than that of collar movement at low speed, and the establishment of dynamic pressure mainly depends on pad tilt and minimum film thickness increases. As the increase of rotational speed, the influence of pad tilt was abated, where the influence of the moving of the collar dominated gradually, and minimum film thickness decreases. For TPTBs, the circumferential angle of the pad is always greater than the radial angle. When the rotational speed is constant, the change rate of radial angle is greater than that of circumferential angle with the increase of loading forces. This study can provide reference for improving bearing wear resistance.

Influence of incident angles of earthquakes on inelastic responses of asymmetric-plan structures

  • Nguyen, Van Tu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • v.45 no.3
    • /
    • pp.373-389
    • /
    • 2013
  • This paper presents the influence of incident angles of earthquakes on inelastic dynamic responses of asymmetry single story buildings under seismic ground motions. The dynamic responses such as internal forces and rotational ductility factor are used to evaluate the importance of the incident angles of ground motions in the inelastic range of structural behavior. The base shear and torque (BST) response histories of the resisting elements and of the building are used to prove that the shape of the BST surface of the building can be a practical tool to represent those of all resisting elements. This paper also shows that the different global forces which produce the maximum demands in the resisting elements tend to converge toward a single distribution in a definable intensity range, and this single distribution is related to the resistance distribution of the building.

A Study on Static Stiffness of Tool Interfaces Considering Cutting Resistance (절삭저항을 고려한 툴 인터페이스부의 정강성 분석)

  • Shin, J.H.;Lee, C.M.;Hwang, Y.K.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.59-64
    • /
    • 2008
  • Spindle units of machine tool are very important part in the manufacturing area. Recently high speed machining has become the main issue of metal cutting. To develop high speed machine tools, a lot of studies have been carried out for high speed spindle. Due to increase of the rotational speed of the spindle, there has been renewal of interest in tooling system of high speed spindle. This paper concerns the static stiffness in the main spindle interface according to variation of clamping force, rotational speed and tool holder shank. Finite element analysis is performed by using a commercial code ANSYS workbench. From the results, it has been shown that the geometry of tool holder shank is mostly influence on the variation of the static stiffness in the main spindle interface.

The Rotational Speed measurement of three-phase Induction Motor by use of delivering unbalanced input from PWM Inverter

  • Okauchi, Shouji;Aoshima, Nobuharu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.413-418
    • /
    • 1998
  • We often use induction motor in the hard environment including vibration and high ambient temperature, or in maintenance free operation, because induction motor has durable and simple structure. However, when we use it as servo actuator or accurate speed control motor, we have to equip sensor such as encoder and tachogenerator with the motor control system. And generally those sensor's abilities against bad environment are less than the induction motor itself, So if we can remove these sensors from the system, it'll have more environmental resistance, and the cost will also be reduced. Actually this removal has been achieved in limited field. However, that needs complex calculations and a certain elapse time for data processing. In our study, we intended to estimate the rotational speed from the motor current instead of speed sensor, easily and rapidly in comparison to former methods.

  • PDF