• Title/Summary/Keyword: rotation rate

Search Result 817, Processing Time 0.031 seconds

An Investigation on $6^{th}$ Grade Students' Spatial Sense and Spatial Reasoning (초등학교 6학년 학생들의 공간감각과 공간추론능력 실태조사)

  • Kim, Yu-Kyung;Pang, Jeong-Suk
    • School Mathematics
    • /
    • v.9 no.3
    • /
    • pp.353-373
    • /
    • 2007
  • The purpose of this study was to provide instructional suggestions by investigating the spatial sense and spatial reasoning ability of 6th grade students. The questionnaire consisted of 20 questions, 10 for spatial visualization and 10 for spatial orientation. The number of subjects for the survey was 145. The processes through which the students solved the problems were the basis for the assessment of their spatial reasoning. The result of the survey is as follows: First, students performed better in spatial visualization than in spatial orientation. With regard to spatial visualization, they were better in transformation than in rotation. With regard to spatial orientation, students performed better in orientation sense and structure cognitive ability than in situational sense. Second, the students that weren't excellent in spatial visualization tended to answer the familiar figures without using mental images. The students who lacked spatial orientation experienced difficulties finding figures observed from the sides. Third, students had high frequency rate on the cognition and use of transformation, the development and application of visualization methods and the use of analysis and synthesis. However they had a lower rate on a systematic approach and deductive reasoning. Further detailed investigation into how students use spatial reasoning, and apply it to actual teaching practice as a device for advancing their geometric thinking is necessary.

  • PDF

Relationships between Shift Work and Occupational Accidents in a Steel Company (철강회사에 있어서 교대작업과 산업재해의 관련성)

  • Seo, Yoo-Jin;Kazuya, Matsumoto;Moon, Se-Keun;Jung, Min-Sang;Kim, Myung-Il
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.188-196
    • /
    • 2005
  • Accident reports from 1991 to 2000 of a steel company were used to analyze which factors induce industrial accidents. The subjects were 8,311 blue-collar workers, who sustained 114 occupational injuries and work on a continuous full-day 3-team 3-shift system of backward rotation(mornings to afternoons to nights). With respect to marital status, the occupational injury rate(OIR) on the married workers was significantly higher compared to unmarried workers. With respect to no, the OIR of those in their early 20s was significantly higher when compared to other age groups. The OIR of highly educated workers showed a reduction when compared with lower educated workers. The OIR of shift workers were significantly higher compared with the daytime workers. The OIR of type of work decreased across the steel manufacturing process, rolling process, machine maintenance section forwarding products section to the field management section. With respect to the block of shift work(morning, afternoon, and night shifts) by the type of work, the OIR of the night shift was higher than those of the morning shift in the steel manufacturing process or forwarding products section. The OIR of the machine maintenance section was slightly higher in the morning shift than those of the night shift. The OIR of the time of day of the shift workers reached a peak between 09:00 and 11:00. The OIR of a slight injury to shift workers decreased across the night, afternoon, to morning shifts whereas the OIR of a serious injury tended to decrease across the night, morning, to afternoon shift. The body parts most commonly injured were the arm and the crus.

Fingerprint Recognition using Linking Information of Minutiae (특징점의 연결정보를 이용한 지문인식)

  • Cha, Heong-Hee;Jang, Seok-Woo;Kim, Gye-Young;Choi, Hyung-Il
    • The KIPS Transactions:PartB
    • /
    • v.10B no.7
    • /
    • pp.815-822
    • /
    • 2003
  • Fingerprint image enhancement and minutiae matching are two key steps in an automatic fingerprint identification system. In this paper, we propose a fingerprint recognition technique by using minutiae linking information. Recognition process have three steps ; preprocessing, minutiae extraction, matching step based on minutiae pairing. After extracting minutiae of a fingerprint from its thinned image for accuracy, we introduce matching process using minutiae linking information. Introduction of linking information into the minutiae matching process is a simple but accurate way, which solves the problem of reference minutiae pair selection with low cost in comparison stage of two fingerprints. This algorithm is invariable to translation and rotation of fingerprint. The matching algorithm was tested on 500 images from the semiconductor chip style scanner, experimental result revealed the false acceptance rate is decreased and genuine acceptance rate is increased than existing method.

Cost Effective Mobility Anchor Point Selection Scheme for F-HMIPv6 Networks (F-HMIPv6 환경에서의 비용 효율적인 MAP 선택 기법)

  • Roh Myoung-Hwa;Jeong Choong-Kyo
    • KSCI Review
    • /
    • v.14 no.1
    • /
    • pp.265-271
    • /
    • 2006
  • In this paper, we propose a new automatic fingerprint identification system that identifies individuals in large databases. The algorithm consists of three steps: preprocessing, classification, and matching, in the classification, we present a new classification technique based on the statistical approach for directional image distribution. In matching, we also describe improved minutiae candidate pair extraction algorithm that is faster and more accurate than existing algorithm. In matching stage, we extract fingerprint minutiaes from its thinned image for accuracy, and introduce matching process using minutiae linking information. Introduction of linking information into the minutiae matching process is a simple but accurate way, which solves the problem of reference minutiae pair selection in comparison stage of two fingerprints quickly. This algorithm is invariant to translation and rotation of fingerprint. The proposed system was tested on 1000 fingerprint images from the semiconductor chip style scanner. Experimental results reveal false acceptance rate is decreased and genuine acceptance rate is increased than existing method.

  • PDF

Relationship between Thoracic Kyphosis and Selected Cardiopulmonary Parameters and Respiratory Symptoms of Patients with Chronic Obstructive Pulmonary Disease and Asthma

  • Aweto, Happiness Anulika;Adodo, Rachel Ilojegbe
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.179-186
    • /
    • 2021
  • Background: Patients with advanced asthma and chronic obstructive pulmonary disease (COPD) have postural deviations such as thoracic hyperkyphosis, forward shoulder posture (FSP) due to an increase in head and cervical protraction, reduced shoulder range of motion and a corresponding increase in scapula elevation and upward rotation. Unlike congenital vertebral kyphosis that are permanent and rigid deformities with bony and other structural deformations which cause respiratory impairment, these deformities in these patients may be more flexible. Since the thoracic hyperkyphosis has been implicated as having adverse health consequences it is necessary to evaluated the relationship between thoracic kyphosis and cardiopulmonary functions of patients with COPD and asthma. Methods: It was a cross-sectional analytical study. Eighty-four eligible patients with COPD and asthma were recruited from the Respiratory Unit, Department of Medicine, Lagos University Teaching Hospital (LUTH), and basic anthropometric parameters, pulmonary parameters, cardiovascular parameters, thoracic kyphosis (Cobb) angle and presence of respiratory symptoms of participants were assessed. Data was analyzed using SPSS version 20. Results: There was no significant correlation between the thoracic kyphosis and selected pulmonary parameters (Forced Expiratory Volume in one second (FEV1, p=0.36), Forced Vital Capacity (FVC, p=0.95), Peak Expiratory Flow Rate (PEFR, p=0.16), Thoracic expansion (TE, p=0.27)/cardiovascular parameters (Systolic Blood Pressure (SBP, p=0.108), Diastolic Blood Pressure (DBP, p=0.17) and Pulse Rate (PR, p=0.93) as well as the respiratory symptoms (SGRQ scores, p=0.11) in all subjects. Conclusion: There was no relationship between thoracic kyphosis and selected pulmonary/cardiovascular parameters as well as respiratory symptoms in patients with COPD and asthma.

A Numerical Study on Effects of Flow Analysis with Flow Control Valve on Turbine of OWC Type Wave Power Generator (유량 조절 밸브가 탑재된 진동수주형 파력발전장치의 터빈 내 유동해석을 위한 수치해석 연구)

  • Ro, Kyoung-Chul;Oh, Jae-Won;Kim, Gil-won;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.801-808
    • /
    • 2021
  • In this paper, a numerical analysis was conducted on the effect of the flow control valve of a oscillation water column(OWC) type wave power generator turbine. The OWC wave power turbine operates with compressed air in the air chamber according to the change of wave height. When the wave height changes rapidly, a flow control valve is required due to overload of the turbine and reduced efficiency. Therefore, in this paper, a flow control valve with an opening angle of 60 degrees was installed in the front of the turbine, and the pressure drop, torque, and overall performance were calculated according to the change of turbine RPM and flow rate of turbine inlet. In conclusion, the flow control valve with an opening angle of 60 degrees affects when the turbine rotates at low rotation and the inlet flow rate is large. But it does not have a significant effect on overall turbine performance and it is necessary to find the optimal angle in the future works.

Evaluation of Moment Transfer Efficiency According to the Connection Length of the Column Flange and the Beam Web of the H-beam Column Connection (H형강 보-기둥 접합부의 보 웨브 단부접합길이에 따른 모멘트전달효율 평가)

  • Hong, Young-Ju;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.193-203
    • /
    • 2022
  • In this study, in order to compare the seismic performance of steel structure beam-column connection details and non-scallop connection details mainly used in Korea, a full-scale static cyclic loading test and FEM analysis were conducted through the same modeling as the experiment. For quantitative numerical comparison, the strain concentration ratio and moment transfer efficiency used in previous studies were cited. As the welding area of the beam web decreased, the deformation rate of the beam flange increased, and the plastic deformation capacity according to the rotation angle decreased or brittle fracture occurred. Comparing the analysis results with the experimental results, the possibility of brittle fracture tended to increase when the web welding ratio for the total cross-sectional area of H-shaped fell below 60%.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

A study on the optical properties of $LiNbO_3$ single crystal grown by Floating zone method (Floating zone 법에 의한 $LiNbO_3$ 단결정의 광학적 특성에 관한 연구)

  • Ko, J.M.;Cho, H.;Kim, S.H.;Choi, J.K.;Auh, K.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.4
    • /
    • pp.318-331
    • /
    • 1995
  • The c - axis oriented single crystal of $LiNbO_3$ and $LiNbO_3$ : 5mol%MgO was success-fully grown by Floating zone method using halogen lamp as a heat source. The effects of the sintering condition of the feed rod and the atmosphere gas during the crystal growth on the be havior of the feed rod/melt interface were studied for growing crystal with the high quality, and then, the optimum growth conditions were determined by studying the experimental param eters, such as gas flow rate, pulling rate, rotation speeds of the feed rod and the seed. The grown crystals were analyzed using the chemical etching to observe the tch pattern and the ICP (Inductively Coupled Plasma) to determine the composition uniformity and the impurity content of Fe. The effects of additive (5 mol % MgO) on the transmittance and refractive index was, also, analyzed. In order to compare the nonlinear optical oharacteristics of $LiNbO_3$ with those of the other optical materials, the nonlinear optical refractive index ($n_2$) was calcu l lated using the measured refractive index.

  • PDF

A Study on the Effects of Rotation Rate and Flow Rate on the Operating Characteristics in Centrifugal Pump (원심펌프에서 회전수 및 유량변화가 운전특성에 미치는 영향)

  • Lim, Kwang-Mook;Lee, Sung-Ill
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.56-62
    • /
    • 2019
  • This study examined effects of the operating characteristics of a pump according to the rotational speed of a pump and the change in flow rate when a centrifugal pump operates under the following conditions: regulated flow rate, head, rotational speed, and specific speed of 0.7 m/min, 8 m, 1750 rpm, an 182 (m, ㎥/min, rpm), respectively. The pump in the experiment did not have a guide vane and was connected directly to the rim, so that the rotational speed of the volute pump in a spiral or volute casing increased by 100 rpm from 1350 to 1750 rpm. The result of the relationship between the H-Q, L-Q, and 𝜂-Q characteristics and the dimensionless performance characteristics, such as the head coefficient, power coefficient and efficiency were studied. The change in pump performance could be estimated depending on the increase in the number of revolutions. The maximum efficiency of the pump was 52% with 1450 rpm, 0.165 ㎥/min flux, and 4.73 m of lift. The efficiency reached 50% with a maximum of 1750 rpm, 0.183 ㎥/min of flux, and 6.72 m of lift. The efficiency curve on the performance characteristics of the lift versus flux curve became oval not a curve from a quadratic equation that passes through the starting point according to the similarity law of the pump. Finally, when the flux coefficient increased, the power coefficient increased and the lift coefficient decreased. When the flux coefficient was 0.08, the maximum efficiency was 52%. Therefore, the change in flux affects the driving characteristics.