• 제목/요약/키워드: rotating fluid

검색결과 575건 처리시간 0.023초

정방형 홈을 가진 회전원주 주위의 유동과 유체력 (Flow and Fluid Force around a Rotating Circular Cylinder with Square Grooves)

  • 강명훈;노기덕;공태희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1460-1465
    • /
    • 2004
  • Flow patterns around a rotating circular cylinder having square dimpled surface were visualized by the hydrogen bubble technique at velocity ratios from a=0 to 4.8 and Reynolds number of $Re=1.0{\times}10^{4}$. The wake region of the cylinder was reduced as the velocity ratios increase and was smaller than that of the smooth cylinder without dimples at the same velocity ratio. The hydrodynamic characteristics on the cylinder was investigated by measuring of lift and drag at velocity ratios from a=0 to 4.1 and Reynolds number from $Re=1.2{\times}10^{4}$ to $Re=2.0{\times}10^{4}$. As the velocity ratios increase, the average lift and drag coefficients were increased and at the same velocity ratio, the average lift was larger but the average drag was smaller than that of the smooth cylinder.

  • PDF

PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan

  • Shigemitsu, Toru;Fukuda, Hiroaki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.175-181
    • /
    • 2016
  • Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.

터보압축기의 스톨 발단에 관한 연구 리뷰 (Review of Stall Inception in Turbocompressors)

  • 강정식;강신형
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.58-65
    • /
    • 2003
  • Stall inception means the phenomena of rotating stall initiation. The initiation mechanism of rotating stall, the existence of stall precursor, the behavior of stall precursor, stall warning scheme and control scheme are the main interests in stall inception research. Compared to the studies on rotating stall which has long history, the stall inception has been studied for about recent 20 years. After the first discovery of stall precursor in about 20 years ago, many studies were reported on stall inception phenomena. The inception pattern of 'mode' and 'spike' were found, and some of its characteristics are known. And now the stall inception has become one of the fascinating fields in turbomachinery. The development stall control scheme which apply the reliable stall warning scheme will play a great role in future compressor and aeroengine. This paper reviews the results and analysis methods on stall inception studies.

Rotating Choke and Choked Surge in an Axial Pump Impeller

  • Watanabe, Toshifumi;Sato, Hideyoshi;Henmi, Yasuhiko;Horiguchi, Hironori;Kawata, Yutaka;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권3호
    • /
    • pp.232-238
    • /
    • 2009
  • Unlike usual turbopump inducers, the axial flow pump tested operates very stably at design flow rate without rotating cavitation nor cavitation surge. Flow visualization suggests that this is because the tip cavity smoothly extends into the flow passage without the interaction with the leading edge of the next blade. However, at low flow rate and low cavitation number, choked surge and rotating choke were observed. Their correlation with the performance curve under cavitation is discussed and their instantaneous flow fields are shown.

딤플이 설치된 회전 유로의 높이가 열전달 계수에 미치는 영향에 대한 실험적 연구 (Effect of channel height on the heat transfer coefficient of a rotation dimpled channel)

  • 김석범;이용진;최은영;전창수;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.30-36
    • /
    • 2010
  • The detailed heat transfer coefficients on a rotating dimpled channel were measured by the hue detection based the transient liquid crystal technique. The dimples were fabricated on the one side of the channel and the tested channel aspect ratio was 4, 6, and 12 with fixed channel width. Tested Reynolds number based on the channel hydraulic diameter was varied from 21,000 to 47,000. A stationary case and two different rotating conditions were tested so that the dimple fabricated surface became leading or trailing surface. For all rotating conditions, the minimum averaged heat transfer coefficient was measured for the channel aspect ratio of 6. Generally, the highest averaged heat transfer coefficient was observed for the highest aspect ratio cases due to increased dimple induced vortex strength.

입구 속도 분포가 매끈한 회전유로 내 열전달계수에 미치는 영향 (Effect of Inlet Velocity Distribution on the Heat Transfer Coefficient in a Rotating Smooth Channel)

  • 최은영;이용진;전창수;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.76-84
    • /
    • 2011
  • The effect of inlet velocity profile on the heat transfer coefficient in a rotating smooth channel was investigated experimentally. Three simulated inlet flow conditions of fully developed, uniform, and distorted inlet conditions were tested. The Reynolds number based on the channel hydraulic diameter was ranged from 10,000 to 30,000 and the transient liquid crystal technique was used to measure the distribution of the heat transfer coefficient in the rotating channel. Results showed that the overall heat transfer coefficient increased as the Reynolds number increased. Also, the distribution of the heat transfer coefficient was strongly affected by the inlet flow condition. Generally, the fully developed flow simulated condition showed the highest heat transfer coefficient.

CD 및 DVD 디스크의 진동 특성 (Vibration Characteristics of CD and DVD Disks)

  • 이승엽;임효석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.998-1003
    • /
    • 2003
  • The aerodynamically excited vibration and natural frequency of rotating CD and DVD disks are analytically and experimentally studied in this paper The theoretical analysis uses a fluid-structure model where the aerodynamic effects are represented in terms of elastic, lift and damping components. The explicit expression on natural frequency of the air coupled disk is obtained as functions of the three aerodynamic coefficients. The experiments performed using a vacuum chamber and CD/DVD disks rotating in vacuum, open air and enclosure give three main results. One is that the aerodynamic effect by the surrounding air reduces the natural frequencies and critical speeds of the vibration modes. The second is that natural frequency of disks rotating in open air is larger than that in enclosure. Finally, it is shown that the disk vibration is reduced as the gap between the disk and the rigid wall decreases.

  • PDF

A Behavior of the Diffuser Rotating Stall in a Low Specific Speed Mixed-Flow Pump

  • Miyabe, Masahiro;Furukawa, Akinori;Maeda, Hideaki;Umeki, Isamu;Jittani, Yoshinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.31-39
    • /
    • 2009
  • The flow instability in a low specific speed mixed-flow pump, having a positive slope of head-flow characteristics was investigated. Based on the static pressure measurements, it was found that a rotating stall in the vaned diffuser occurs at about 65% flow rate of best efficiency point (BEP). A dynamic Particle Image Velocimetry (DPIV) measurement and the numerical simulations were conducted in order to investigate the flow fields. As a result, the diffuser rotating stall was simulated even by Computational Fluid Dynamics (CFD) and the calculated periodic flow patterns agree well with the measured ones by DPIV. It is clarified that a periodical large scaled backflow, generated at the leading edge of the suction surface of the diffuser vane, causes the instability. Furthermore, the growth of the strong vortex at the leading edge of the diffuser vane induces the strong backflow from the diffuser outlet to the inlet. The scale of one stall cell is covered over four-passages in total thirteen vane-passages.

HDD 스핀들 시스템에 사용되는 저널과 트러스트가 결합된 유체 동압 베어링의 홈 위치에 따른 동특성 해석 (Dynamic Characteristics of a Coupled Journal and Thrust Hydrodynamic Bearing in a HDD Spindle System Due to Groove Location)

  • 윤진욱;장건희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.304-311
    • /
    • 2001
  • This research numerically analyzes the dynamic characteristics of a coupled journal and thrust hydrodynamic bearing due to its groove location which has the static load due to the weight of a rotor in the axial direction and the dynamic load due to its mass unbalance in the radial direction. The Reynolds equation is transformed to solve a plain member rotating type of journal bearing(PMRJ), a grooved member rotating type of journal bearing (GMRJ), a plain member rotating type of thrust bearing (PMRT) and a grooved member rotating type of thrust bearing (GMRT). FEM is used to solve the Reynolds equations in order to calculate the pressure distribution in a fluid film. Reaction forces and friction torque are obtained by integrating the pressure and shear stress along the fluid film, respectively. Dynamic behaviors, such as whirl radius or floating height of a rotor, are determined by solving its nonlinear equations of motion with the Runge-Kutta method. This research shows that the groove location affects the pressure distribution in the fluid film and consequently the dynamic performance of a HDD spindle system.

  • PDF