PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan  

Shigemitsu, Toru (Institute of Technology and Science, Tokushima University)
Fukuda, Hiroaki (Graduate School of Advanced Technology and Science, Tokushima University)
Fukutomi, Junichiro (Institute of Technology and Science, Tokushima University)
Publication Information
International Journal of Fluid Machinery and Systems / v.9, no.2, 2016 , pp. 175-181 More about this Journal
Abstract
Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.
Keywords
Cooling fan; PIV measurement; Internal flow; Contra-rotating rotor;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Hata, T and Nakamoto, S., 2010, "Energy Saving Service for Data Centers," J. the Japan Society for Precision Engineering(in Japanese), Vol.76, No.3, pp.272-275.   DOI
2 Miyahara, M and Fukano, T., 2006, "Fan Cooling Technology for Small Electronic Device," Turbomachinery(in Japanese), Vol. 34, No3, pp.129-134.
3 Ito, T., Minorikawa, G and Fan, Q., 2009, "Experimental Research for Performance and Noise of Small Axial Fan," Int. J. Fluid Machinery and Systems, Vol.2, No.2, pp.136-146.   DOI
4 Liu, P., Shiomi, N., Kinoue, Y., Setoguchi, T and Jin, Y., 2014, "Effect of Inlet Geometry on Fan Performance and Inlet Flow Fields in a Semi-opened Axial Fan," Int. J. Fluid Machinery and Systems, Vol.7, No.2, pp.60-67.   DOI
5 Furukawa, A., Shigemitsu, T and Watanabe, S., 2007, "Performance Test and Flow Measurement of Contra-Rotating Axial Flow Pump," J. Thermal Science, Vol.16, No.1, pp.7-13.   DOI
6 Furukawa, A., Cao, Y., Okuma, K and Watanabe, S., 2000, "Experimental Study of Pump Characteristics of Contra-Rotating Axial Flow Pump," Proc. 2nd Int. Symp. on Fluid Machinery and Fluid Eng., Beijing, 67-657, pp.245-252.
7 Kodama, Y., Hayashi, H., Fukano, T and Tanaka, K., 1994, "Experimental Study on the Characteristics of Fluid Dynamics and noise of a Counter-Rotating Fan(1st Report, Effects of the Supporter Shape of the Electric Motor and the Distance between Two Rotors on the Characteristics)," Trans. JSME (in Japanese), Vol. 60, No. 576, pp.2764-2771.
8 Nouri, H., Ravelet, F., Bakir, F and Sarraf, C., 2012, "Design and Experimental Validation of a Ducted Counter-Rotating Axial-Flow Fans System," ASME J. Fluids Engineering, Vol.134, No.10, 104504.   DOI
9 Shigemitsu, T., Fukutomi, J and Agawa, T., 2013, "Performance Characteristics and Flow Conditions of High Pressure and Large Flow Rate Cooling Fan," Proceedings of the ASME Fluids Engineering Division Summer Meeting, Lake Tahoe, Nevada, USA.
10 Shigemitsu, T., Fukutomi, J and Agawa, T., 2013, "Internal Flow Condition of High Power Contra-Rotating Small-Sized Axial Fan," International Journal of Fluid Machinery and Systems, Vol.6, No.1, pp.25-32.   DOI
11 Tanaka, K., Shigemitsu, T., Fukutomi, J and Shimizu, H., 2013, "PIV Measurement for Contra-Rotating Small-Sized at Partial Flow Rate," Turbomachinery Society of Japan Annual Conference(in Japanese).