• 제목/요약/키워드: room cooling

검색결과 486건 처리시간 0.026초

생체용 순수 Ti 주조체의 냉각방법에 따른 주조조직과 부식특성 및 경도에 관한 연구 (A study on microstructure, corrosion characteries and hardness of pure Ti according to cooling methods)

  • 김재도
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.65-73
    • /
    • 2001
  • The purpose of this study was to investigate the microstucture and hardness, corrosion of pure Ti alloy, which is widely used as partial denture frame work these days, depending on the cooling method, followed by casting. The first group was bench cooling at room temperature($18^{\circ}C$), the second group was slowly cooled in the furnace from $700^{\circ}C$ to room temperature, and third. rapidly cooled in $0^{\circ}C$ water. The microstructure of each specimen observed by means of photomicrograph taken by electron microscope, in add to the physical characteristics of each specimen were obtained using the rockwell Hardnest Number. the characteristics of corrosion. The results were obtained as follows: 1. From Potentiodynamic plot. we conclude furnace-cooled specimen had the best stabiltity of passive film and that air-cooled specimen showed similar characteristics. The density of electric current of quenched specimen was the highest, which formed kind of unstable passive film. 2. Specimen cooled at room temperature (air cooling) had the highest value of hardness of 81.26HRB, specimen cooled at ice-water, $0^{\circ}C$, had the value of 78.42HRB, and specimen furnace-cooled at $700^{\circ}C$ had lowest value of 77.1HRB. 3. Quenching treated micro-structure formed martensite structure by and large. In case of air cooling, we could see $\alpha$-structure widmanstatten formed overall. In furnace cooling, widmanstatten structure and various shape $\alpha$-structures forming colony with direction were detected.

  • PDF

지방 고등학교 기숙사의 공동생활공간에 대한 이용실태 및 사용자 만족도 (Physical Condition and User's Satisfaction on the Commom Public Areas of High School Dormitory in Local Area)

  • 최병숙;안진숙
    • 한국농촌건축학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 2012
  • This study was to analyze physical condition on the dormitory high school in Jeonju City, and find out users' satisfaction on that. This was going to contribute to the directions of it's physical environmental improvement. This was performed by a questionnaire survey method. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. Through analyzing those data about library, diningroom, laundry room, break room, computer room, restroom, shower room, hall lounge, and snack bar in a dormitory, the results are as follows. First, students thought some physical conditions to be inconvenient in an distracted study atmosphere and hard furniture of library, a bad location of diningroom, a short laundry machine, lack of tables in a break room, a short performance and supply computer, a small space and short toilet in restroom, and a short of hall lounge and snack bar. Second, the students' satisfaction of common public areas in dormitory was 3.39 score. Students were concerned with library and restroom shower room through analyzing satisfied and unsatisfied areas. Third, they needed to improve heating, cooling, and noise in common areas of dormitory, and needed to support a breakroom and snack bar. Conclusively, library, restroom shower room, break room, and snack bar were important common areas, and indoor environmental elements - heating, cooling and noise- were important in high school dormitory.

일사차단용 설비를 이용한 냉방 에너지 절약 방안 (Cooling Energy Saving System using Solar Heat Protection Dvices)

  • 정기범;최상곤
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

가열냉각방법에 의한 마그네슘합금의 판재성형성 개선 (Improvement on the Formability of Magnesium Alloy Sheet by Heating and Cooling Method)

  • 강대민
    • 소성∙가공
    • /
    • 제14권7호
    • /
    • pp.607-612
    • /
    • 2005
  • In this paper, warm deep drawing process with local heating and cooling technique was attempted to improve the formability of AZ31 magnesium alloy which is impossibly to form by conventional methods at room temperature by finite element method and experiment. For FE analysis, in first model with considering heat transfer, both die and blankholder were heated to 573K while the punch was kept at room temperature by cooling water. Also distribution of thickness and von Mises stress at room temperature and 498k for warm deep drawing were compared by FEM. Uniaxial tension tests at elevated temperature were done in order to obtain the temperature dependence of material constant under temperature of $293K\~573K$ and cross head velocity of $5\~500mm/min$. The phenomenological model for warm deep drawing process in this work was based on the hardening law and power law strain rate dependency. Deep drawing experiment were conducted at temperatures of room temperature, 373K, 423K, 473K, 498K, 523K, and 573K for the blank and deep drawing tools(holder and die) and at a punch speed of 10mm/min.

냉방설비 성능개선 및 에너지 절약을 위한 응결수 활용성 분석 (An analysis on the utility of congealing water to improve efficiency of the air cooling equipment and save energy)

  • 박근수;박영호;유정범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.974-981
    • /
    • 2007
  • Seoul Metro has operated the air cooling equipment established in a machine room of a station building to improve our services focused on our customers who use Seoul Metro during the summer season. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. One of them is loss of efficiency in the air conditioner. The leading cause of this problem is that we use an underground type of the cooling tower. As the machine room of a station building is located in the underground of inner city because of the nature of the subway, it is difficult to establish the cooling tower on the ground. The underground structure of the No. $1{\sim}4$ subway line is unsuitable for the location requirements of the underground type of the one because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. Accordingly, the efficiency of the air conditioning is getting lower and lower. Another problem is too wasteful with water. Each station uses the water over 30 tons every day with waterworks to replenish the cooling tower such as a evaporation, a scattering and a distribution of water. Nevertheless, the more an air conditioner increase, the more the use of water supply increase. For this reason, we can't help wasting an enormous amount of water and discharging the congelation of a low temperature(about $15^{\circ}C$) occurred in a heat exchanger inside an air conditioner. The purpose of this study is to analyze the utility of congealing water to improve efficiency of the air cooling equipment and save energy as a supplementary water for the cooling tower.

  • PDF

모의 수출 실험을 통한 고랭지 사계성 딸기 'Goha'와 'Flamenco'의 유통 온도 및 예냉 처리효과 (Effects of Shipping Temperature and Precooling Treatment of Everbearing Strawberry Cultivars 'Goha' and 'Flamenco' Grown on Highland through Export Simulation)

  • 엄향란;배상준;황대근;용영록;홍세진
    • 원예과학기술지
    • /
    • 제32권2호
    • /
    • pp.202-209
    • /
    • 2014
  • 본 연구는 사계성 딸기인 'Flamenco'와 'Goha' 품종을 이용하여 모의수출을 실시함으로써 사계성 딸기의 수출 시 저온유통 및 예냉기술의 필요성을 제안하고자 하였다. 과실을 수확한 다음 예냉, 선별, 저장, 운송, 검역 및 하역작업에 소요된 기간인 2일 경과 후부터 상온과 저온의 조건에서 유통을 실시하였다. 상온 유통은 'Flamenco'와 'Goha' 품종 모두 유통기간 1일이 경과된 후 무게손실률이 크게 증가하여 2일 경과 후 10% 정도로 증가하였으며, 'Goha' 품종이 'Flamenco' 품종에 비해서 2% 가량 중량 감모율이 높았다. 'Flamenco' 품종은 예냉처리 유무 및 상온과 저온 유통기간 동안 경도와 가용성 고형물의 함량 변화가 없는 반면, 'Goha' 품종은 차압식 예냉처리에서 상온 및 저온 유통기간 동안 경도의 감소폭이 컸고 저장 4일 경과 후에는 통풍식 예냉 및 저온유통에서 경도유지에 효과적이었다. 적정산도는 두 품종 모두 유통기간 동안 유지되거나 오히려 증가하는 양상을 보이며, 특히 'Goha' 품종에서 유통온도($P{\leq}0.001$) 및 예냉처리 유무($P{\leq}0.05$)가 적정산도에 영향을 미쳤다. 저온 유통은 딸기의 착색 및 곰팡이 발생을 지연시키는데 효과적이며, 예냉처리에 의해서 곰팡이 발생빈도를 낮출 수 있었다. 수출용 사계성 딸기의 $8^{\circ}C$ 이하의 저온에서는 유통 기간이 4일 이상 연장되며, 차압식 예냉과 통풍식 예냉의 실시는 저온유통을 실시할 경우 효과적이었다. 품종별 예냉 처리 효과는 'Flamenco' 품종은 차압식 예냉과 통풍식 예냉이 유사한 반면, 국내 육성종인 'Goha' 품종은 통풍식 예냉의 효과가 좋았다.

외부공기 유입관을 이용한 컴퓨터 냉각시스템의 효율향상에 관한 연구 (A Primary Study on the Enhancement of Efficiency in the Computer Cooling System using Entrance Tube of Outer Air)

  • 김순호;김문환
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.56-61
    • /
    • 2009
  • In recent years, since the continuing increase in the capacity in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates the ability and efficiency of a cooling system inside a computer by means of central processing unit (CPU) and power supply cooling fan. This research was conducted to enhancement of efficiency of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as $5^{\circ}C$, $2.5^{\circ}C$ and $7^{\circ}C$ respectively. In addition to, revolution per minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.

  • PDF

창호일체형 환기시스템 및 중앙냉방시스템 연계 운영에 대한 수치해석적 연구 (Numerical Analysis on the Coupled Operation of Ventilation Window System and Central Cooling System)

  • 박동윤;장성주
    • 한국대기환경학회지
    • /
    • 제31권4호
    • /
    • pp.385-395
    • /
    • 2015
  • This study evaluated indoor environmental characteristics in an office room equipped both with ventilation window system and central cooling system. Fresh air is supplied only by the central cooling system whereas indoor air is discharged outside through both ceiling diffuser and a ventilation window system. Numerical study is conducted by changing the volumetric flow rates of exhaust ports of each system. For estimating the performance of this coupled system, $CO_2$ concentration and Predicted Mean Vote (PMV) were calculated using Computational Fluid Dynamics (CFD) simulation. The more the ceiling diffuser exhausts indoor air, the more the $CO_2$ concentration decreases. However, when the ventilation window system exhausts more indoor air, thermal comfort level gets improved in the office room with cooling system. Therefore, when the ventilation window system is operated, the coupled operation with central cooling system should be considered for enhancing indoor air quality and thermal comfort, together.

태양열에 의한 냉방 및 난방시스템의 성능향상(I) - TRNSYS에 의한 동직열부하 계산과 태양열 시스템의 최적화 - (Improvement of the Performance of Solar Cooling Heating Systems(I) - Dynamic Load Calculation Using TRNSYS and an Optimization of Solar Systems -)

  • 강용태;김효경;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제17권6호
    • /
    • pp.696-707
    • /
    • 1988
  • This study simulates a typical solar system using the transient simulation program TRNSYS, and calculates the maximum cooling load of the model room of $50m^2$. In this study, energy rate control method is used in calculating a maximum cooling load. On the ground of the maximum cooling load of the model room, the variables that have an effect on the solar collection performance of the solar system are made a selection. Also in this study the trend of the solar collection performance is shown as the variables change. The results show that the variables which have an effect on the collection performance are collector area, collector mass flow rate, collector slope and the volume of storage tank, and the optimal value of Ac/Vt is not constant but varies as the collector area and the collector mass flow rate. Also the results show that for cooling system the optimal value of the collector slope is latitude minus $15^{\circ}$ during the seasonal operations, and twenty percent of the maximum cooling load is saved with the aid of the solar energy.

  • PDF

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.