A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center  

Chang, Hyun Jae (School of Architectural Engineering, Hongik University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.30, no.2, 2018 , pp. 83-91 More about this Journal
Abstract
A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.
Keywords
Data center; Supply air temperature; Rack cooling index(RCI); Return temperature index(RTI);
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kim, J. Y., Chang, H. J., Jung, Y. H., Cho, K. M., and Augenbroe, G., 2017, Energy Conservation Effects of a Multi-Stage Outdoor Air Enabled Cooling system in a Data Center, Energy and buildings, Vol. 138, pp. 257-270.   DOI
2 Park, M. K. and Chang, H. J., 2017, A Study on the Regional Energy Conservation Effects of a Multi-Stage Outdoor Air Enabled Cooling System in a Data Center, Journal of the Korean Solar Energy Society, Vol. 37, No. 1, pp. 71-80.   DOI
3 ASHRAE, ASHRAE datacom series : Thermal guidelines for data processing environments, 2011.
4 Patterson, M. K., 2008, The Effect of Data Center Temperature on Energy Efficiency, IEEE 2008, 978-1-4244-1701-8, pp. 1167-1174.
5 Fallah, F. and Pedram, M., 2005, Standby and Active Leakage Current Control and Minimization in CMOS VLSI Circuits, IEICE Transactions on Electronics, Vol. E88-C, No. 4, pp. 509-519.   DOI
6 Moss, D. and Bean, J. H., 2011, Energy Impact of Increased Server Inlet Temperature, APC White paper 138.
7 Neudorfer, J., 2016, Controlling supply air intake temperatures, Special reports of DATA CENTER Frontier.
8 Patankar, S. V., 2010, Airfolow and cooling in a data center, Journal of Heat Transfer, Vol. 132, pp. 073001-1- 073001-17.   DOI
9 Ham, S. W., Park, J. S., and Jeong, J. W., 2015, Optimum supply air temperature ranges of various air-side economizers in a modular data center, Applied Thermal Engineering, Vol. 77, pp. 163-179.   DOI
10 Cho, J. K. and Kim, B. S., 2008, The cooling and air distribution systems for the optimal IT environment control in the internet data center, Journal of the architectural institute o Korea (Planning & design), Vol. 24, No. 2, pp. 313-320.
11 Chang, H. J. and Kim, J. Y., 2014, A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 26, No. 3, pp. 108-114.   DOI
12 Chang, H. J., Jung, Y. H., and Seo, J. H., 2013, A study on the methodology of simulation on the distribution of airflow and temperature in a date center by utilizing porous boundary condition, J. of KIAEBS, KIAEBS, pp. 289-294.
13 ANSYS FLUENT MANUAL, ANSYS.
14 Sharma, R. K., Bash, C. E., and Patel, C. D., 2002, Dimensionless parameters for evaluation of thermal design and performance of large scale data centers, Proceedings of AIAA 2002-3091, American Institute of Aeronautics and Astronautics Conference.
15 Cho, J. K. and Kim, B. S., 2011, Evaluation of air management system's thermal performance for superior cooling efficiency in highdensity data centers, Energy and Buildings, pp. 2145-2135.
16 Herrlin, M. K., 2005, Rack cooling effectiveness in data centers and telecom central offices: the rack cooling index (RCI), ASHRAE Transactions, Vol. 111, No. 2, pp. 1-11.
17 Herrlin, M. K., 2007, Improved data center energy efficiency and thermal performance by advanced airflow analysis, in : Proceedings of Digital Power Forum, pp. 10-12.