• Title/Summary/Keyword: rooftop park

Search Result 61, Processing Time 0.028 seconds

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.

A Study on Spatial Characteristics of Indoor Rest Zones in the Campus Buildings (대학 캠퍼스 건물 내부휴게공간의 공간적 특성에 관한 연구)

  • Park, Joon-Soo;Kim, Sung-Ah;Suh, Ki-Young;Park, Chang-Hui;Yi, Seong-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.3
    • /
    • pp.37-43
    • /
    • 2003
  • This study investigates the physical characteristics of indoor rest zones using the Space Syntax Method. A conceptual framework is based on analysis of design works presented in competitions(544 rest zones of 24 buildings on 7 campuses). The analysis on the unit type of rest zones showed that they were mostly available as open type, followed by semi-open type and outdoor rest places. On the other hand, by classifying the shape of whole building into traffic lines and nodal points, it was found that the buildings with 3 or more traffic lines have lower availability than others, because the buildings required more nodal points along a little higher complexity and zoning formed at increased nodal points between building masses. The analysis on the location of rest zones on traffic lines showed that hall type was most excellent in the level of availability. Finally, the analysis on the floor height showed that hall-like open rest places and outdoor places like rooftop garden functioned as a factor to enhance the integration of different spaces. In conclusion, this research will help the follow-up studies make spatial creation planning that may enhance the spatial efficiency and availability of Indoor rest zones on the campus.

A Study on Trend of Tensile Properties with Ratio of Water Mixture under Low and High Temperature Environment in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막재의 물 혼합비에 따른 저온 및 고온 환경에서의 인장성능 변화 추이 연구)

  • Kim, Dong-Bum;An, Hyun-Ho;Kim, Sun-Do;Park, Wan-Goo;Park, Jin Sang;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.211-212
    • /
    • 2016
  • Due to a lack of objective and adequate study on the physical effects on hydroponic polyurethane waterproofing material water mixture ratio, construction site workers are having to rely on their hands-on experience to determine a mixture ratio, resulting in difficulty of maintaining quality management. Particularly in cases of rooftop exposed type hydroponic polyurethane materials, the varying temperature conditions make it further difficult for quality management control. in this regard, this study conducts tensile strength testing and compares the tensility change rates hydroponic polyurethane waterproofing materials with various water mixture ratios ranging from 0%~50% and exposed to alternating temperature change between -20℃ to 60℃ in the span of 1 hour after curing for 14 days.

  • PDF

Users' Satisfaction from the Use of Park and Greens based on their Utilization in Gwangju-si (광주시 공원녹지 이용자의 이용 행태에 따른 만족도)

  • Jung, Su-Dong;Yeom, Sung-Jin;Seo, Joung-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.2
    • /
    • pp.1-17
    • /
    • 2021
  • As population concentration, high-rise, and high-density progresses amid rapid industrialization and urbanization in Korea, green areas in the city have decreased significantly and the natural environment has deteriorated day by day due to various development projects. In order to cope with these social changes, many studies related to park and green areas have been conducted, but in the case of Gwangju-si, only studies on green areas such as vegetation structures, street facilities, and recreation forests have been conducted on park green areas. The situation is not losing. Therefore, in this study, a survey was conducted on Gwangju citizens to understand the usage behavior and satisfaction of park green areas, and to provide basic data for future park development and reorganization. As a result, first, to induce a variety of static and dynamic activities in order to increase the park satisfaction of Gwangju citizens, it is possible to create a park that has not been formed as soon as possible, and by planning programs with various themes. Second, it is necessary to expand green space services in marginalized areas by creating water streams, flower pots, and rooftop greening around the lives of Gwangju citizens, and create park green spaces with themes using cultural and historical resources for each administrative district. Third, in order to solve the dry landscape in some urban areas, it is necessary to establish a three-dimensional landscape plan by creating a variety of green areas such as potted plants, green areas, and street trees, and by giving functions of park green areas such as expanding leisure and convenience facilities.

Avaliable analysis of precise positioning using the LX-PPS GNSS permanent stations (LX-PPS GNSS 상시관측소의 정밀측위 활용 가능성 분석)

  • Ha, Jihyun;Park, Kwan-Dong;Kim, Hye-In
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.1
    • /
    • pp.23-38
    • /
    • 2021
  • In this paper, we analyzed the possibility of utilizing LX-PPS GNSS permanent stations whose antennas are installed on the building rooftop for the purpose of high-precision GNSS positioning services. We picked 15 pairs of adjacent GNSS permanent stations operated by LX-PPS and NGII, and then produced 3-year-long time series using the high-precision data processing software called GIPSY. Patterns and trends of position estimates were compared and analyzed. Horizontal and vertical deviations including the linear velocities coincide with the well-known crustal deformation rates of the Korean peninsula. We also observed almost the same annual or seasonal patterns from those nearby sites. After detrending the linear velocity, the amplitude and phase of annual signals almost perfectly match each other within the baseline length of 2 km. By subtracting seasonal signals, the RMS and standard deviations in LX-PPS PPGR with respect to NGII KANR are about 1, 2, and 5 mm in the north-south, east-west, and vertical directions, respectively. From this analysis it can be concluded that the rooftop-installed LX-PPS sites show similar level of stability and positioning performance comparable to those ground-mounted NGII stations.

A Study on the Application of Solar Energy System in Apartment Complex (공동주택단지에서의 태양에너지 시스템 적용에 관한 연구)

  • Jung, Sun-Mi;Chung, Min-Hee;Park, Jin-Chul;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.43-48
    • /
    • 2009
  • In this study, through case studies, solar energy systems were coordinated with architectural plan elements and the others in apartment complex, and the energy performance was evaluated quantitatively through computer simulation PVSYST and RETScreen. As a results, in plan process of the application of solar energy systems in apartment complex, solar energy system should be considered as not only energy reducing technical element but also part of architectural plan element. And it must be considered with architectural plan elements, composition methods, energy storage methods, technical elements from the early basic plan stage. Photovoltaic system was installed on the wall facing the south and rooftop. The energy ratio of electric load was shown to be 5.5%. The result showed 7.2% when adding it to shading device additionally, and 6.4% in case of putting extra translucent module on windows. Active solar collecting system was applied on roof with the angle of 45. Maximum number of solar collector was 10 in a row, and the total solar collecting area was $915.00m^2$. The energy ratio of domestic water heating load by active solar hot water system is shown to be 11.4%.

  • PDF

Performance Evaluation of BIPV Systems Applied in School Buildings (학교 건축에 대한 BIPV시스템의 성능 평가)

  • Park, Kyung-Eun;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.5
    • /
    • pp.14-23
    • /
    • 2004
  • Building-integrated photovoltaic(BIPV) systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Besides of these benefits, the application of PV systems into school buildings tends to play an important role in energy education to students. In this context, this study aims to analyse the applicability of PV systems into school buildings. For an existing school building, four types of BIPV designs were developed; rooftops, wall-attached, wall-mounted with angle, and sunshading device. Based on energy modeling of those BIPV systems, the whole 60.1kWp rated PV installation is expected to yield about 65.6MWh of electricity, that is about 50% more than the annual electricity consumption of the school, 44MWh. It was also found that the applicability of the PV systems into the school building was very high, and the rooftop systems with the optimized angle was the most efficient in energy production, followed by sunshading, wall-mounted with angle and wall-attached. It concludes that school buildings have a reasonable potential to apply PV systems in the aspects of building elements and electricity production.

A Study on Computer Simulation to Investigate Correlations between Temperature Controlling Effect of Green Roof System and the Photovoltaic Power Generation Efficiency (옥상녹화시스템의 기온조절효과와 태양광발전효율간의 상호연관성 규명을 위한 전산해석연구)

  • Kim, Tae Han;Park, Sung Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.70-79
    • /
    • 2013
  • These day cities experience serious climatic changes due to environmental load caused by disturbance in the circulation systems of water resources and energy. As technological improvement to respond to various climatic changes and disasters are also requested in the field of construction, inter-disciplinary studies linked to the establishment of sustainable environmental control and energy systems is required in a consilient perspective. This study aims to infer correlations in the impact of environmental changes caused by rooftop greening system on the photovoltaic power generation efficiency through computer simulation in an integrated perspective. By doing so, it seeks to provide basic study for developing a photovoltaic system integrated with building revegetation that is sustainable in environmental and resource aspects. A simulation showed that, in the case of sunshine hours in June, the green surface indicated temperature lowering effects of $9.19^{\circ}C$ on average compared to the non-green surface and temperature was $9.81^{\circ}C$ lower. Due to such greening effects, at the highest sunlight timepoint in June, Pmpp improved 119W and heat loss rate dropped 7.8%.

The Study of Characteristic of Induced Erythema and Safety by UVB Lamp (UVB조사기의 홍반 발생 특성과 안전성에 관한 연구)

  • Park, Rae-Joon;Cho, Yong-Ho;Park, So-Hyun;Lee, Yoon-Mi
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.79-87
    • /
    • 2006
  • Purpose: The present study purposed to examine induced characteristic or erythema and safety by medium wave ultra violet(UVB) lamp. Methods: We compared sunshine and UVB lamp using spectroradiometer and UV radiometer. For measuring sunshine irradiation, we used spectoradiometer and detected from 8 to 18 o'clock every each hour on the beach, playground and rooftop of a 5 story building. The subjects for erythema examination were 5 healthy subjects who have no pathologic history of photosensitivity reaction, psoriasis and vitiligo. They were exposed to UVB radiation at the abdominal area for 2 hours and after irradiation, we observed the change of skin color every 12 hours over a period of 1 week. Results: Between sunshine and UVB lamp, sunshine had higher data on the chromaticity coordinates, dominant and peak wavelength, bandwidth and purity than the UVB lamp but on the color temperature, brightness the UVB lamp had higher data than the sunshine. In comparison of sunshine and UVB lamp, UVB lamp irradiated constantly such as $3.9-4.4{\mu}W/cm^2$ at a distance of 100cm between bed and lamp which was same as early morning irradiation on the sunshine. The erythema didn't appear to any subject. Conclusion: This results suggest that the UVB lamp has lower irradiance as much as early sunshine. Therefore the UVB lamp had no influence of inducing erythema at a distance of 100cm between bed and lamp.

  • PDF

Planning Directions for Parks and Green Spaces in Future Industrial Complexes according to Changes in the Industrial Environment (산업환경 변화에 따른 미래형 산업단지의 공원녹지 계획방향에 관한 연구)

  • Lee, Eun-yeob;Lee, Hyeon-Ju;Kim, Tae-Gun;Choi, Dae-Sik;Song, Young-il
    • Journal of Environmental Science International
    • /
    • v.30 no.2
    • /
    • pp.109-118
    • /
    • 2021
  • Due to changes such as those stemming from the onset of the fourth industrial revolution, it is expected that industrial complexes will transform from being spacious structures into smaller, integrated complexes. Green parks, which are also a type of infrastructure within industrial complexes, also require planned direction suited to the changing environment. The planned directions of green parks in new industrial complexes were examined and surveys were conducted on industrial complex workers. Preferred functional arrangement, importance, and satisfaction levels of green ratios, preference of compound facilities linked to parks, appropriate dimensional greening methods were all surveyed across 1,035 businesses. Results of the survey exhibited that there was high awareness on the importance of building green areas, but it was found that current greenery levels were insufficient. There was a high rate of responses indicated that dimensional greening is required in building-type industrial spaces, and preferences for rooftop greenery, stair-type greenery, and atrium greenery were also high. There were many opinions that it is necessary to integrate cultural facilities, exhibition and educational facilities, commercial facilities, parking lots in parks. Furthermore, it was found that it is necessary to provide pathways for bikes and pedestrians, rather than those for vehicles, and to connect them with the green parks. This study stopped short of exploring the directions for which green parks should aim in new industrial complexes with changes in the industrial environment. In the future, more concrete plans on green park planning techniques according to the spatial characteristics and structures of new industrial complexes will be necessary.