• Title/Summary/Keyword: rooftop

Search Result 282, Processing Time 0.026 seconds

3D Line Segment Detection using a New Hybrid Stereo Matching Technique (새로운 하이브리드 스테레오 정합기법에 의한 3차원 선소추출)

  • 이동훈;우동민;정영기
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.4
    • /
    • pp.277-285
    • /
    • 2004
  • We present a new hybrid stereo matching technique in terms of the co-operation of area-based stereo and feature-based stereo. The core of our technique is that feature matching is carried out by the reference of the disparity evaluated by area-based stereo. Since the reference of the disparity can significantly reduce the number of feature matching combinations, feature matching error can be drastically minimized. One requirement of the disparity to be referenced is that it should be reliable to be used in feature matching. To measure the reliability of the disparity, in this paper, we employ the self-consistency of the disunity Our suggested technique is applied to the detection of 3D line segments by 2D line matching using our hybrid stereo matching, which can be efficiently utilized in the generation of the rooftop model from urban imagery. We carry out the experiments on our hybrid stereo matching scheme. We generate synthetic images by photo-realistic simulation on Avenches data set of Ascona aerial images. Experimental results indicate that the extracted 3D line segments have an average error of 0.5m and verify our proposed scheme. In order to apply our method to the generation of 3D model in urban imagery, we carry out Preliminary experiments for rooftop generation. Since occlusions are occurred around the outlines of buildings, we experimentally suggested multi-image hybrid stereo system, based on the fusion of 3D line segments. In terms of the simple domain-specific 3D grouping scheme, we notice that an accurate 3D rooftop model can be generated. In this context, we expect that an extended 3D grouping scheme using our hybrid technique can be efficiently applied to the construction of 3D models with more general types of building rooftops.

A Study on Output Monitoring of Green Roof Integrated PV System through Surface Temperature Algorithm (표면온도 알고리즘을 통한 옥상녹화통합형 태양광시스템의 출력 모니터링 연구)

  • Kim, Tae-Han;Park, Sang-Yeon
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.89-95
    • /
    • 2015
  • The centralized power supply system and rainwater treatment system, which are major infrastructure in modern cities, are showing their limitations in accommodating environment load due to climate changes that has aggravated recently. As a result, complex issues such as shortage of reserve power and urban flooding have emerged. As a single solution, decentralized systems such as a model integrating photovoltaic system and rooftop greening system are suggested. When these two systems are integrated and applied together, the synergy effect is expected as the rooftop greening has an effect of preventing urban flooding by controlling peak outflow and also reduces ambient temperature and thus the surface temperature of solar cells is lowered and power generation efficiency is improved. This study aims to compare and analyze the monitoring results of four algorithms that define correlations between micro-climate variables around rooftop greening and the surface temperature of solar cells and generate their significance. By doing so, this study seeks to present an effective algorithm that can estimate the surface temperature of solar cell that has direct impact on the efficiency of photovoltaic power generation by observing climate variables.

The Characteristics of Air Temperature according to the Location of Automatic Weather System (AWS 설치장소에 따른 기온 특성)

  • Joo, Hyong-Don;Lee, Mi-Ja;Ham, In-Wha
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Due to several difficulties, a number of Automatic Weather Systems (AWS) operated by Korea Meteorological Administration (KMA) are located on the rooftop so that the forming of standard observation environment to obtain the accuracy is needed. Therefore, the air temperature of AWSs on the synthetic lawn and the concrete of the rooftop is compared with the standard observation temperature. The hourly mean temperature is obtained by monthly and hourly mean value and the difference of temperature is calculated according to the location, the weather phenomenon, and cloud amount. The maximum and the minimum temperatures are compared by the conditions, such as cloud amount, the existence of precipitation or not. Consequently, the temperature on the synthetic lawn is higher than it on the concrete so that it is difficult to obtain same effect from ASOS, on the contrary the installation of AWS on the synthetic lawn seem to be inadequate due to heat or cold source of the building.

A Study on Improving Water Proofing System of the roof (옥상방수 개선방향에 대한 연구)

  • Kwon Byung-Hun;Heo Jae-Hoon;Lee Sung-Il;Han Jung-Hoon;Kim Chang-Duk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.535-538
    • /
    • 2004
  • Recently, people have been more interested in the quality of the apartment house, and the new trend has come out, which we use the rooftop of big buildings, people take a propound interest in materials and methods of the rooftop waterproofing. So far, many methods have been developed for convenience of maintenance and use. However, we don't have enough methods and materials to handle many problems and causes. We need the method which is not influenced by movement and cracks of substrate.. Therefore, what we are going to do is to check and analyze the present waterproofing methods of the rooftop and then suggest the new way.

  • PDF

A Study on Optimizing of Roof-Top Photovoltaic Arrays Arrangement Based on Three-Dimensional Geo-Spatial Information (3차원 지형공간정보 기반 지붕형 태양광 어레이 배치 최적화 연구)

  • Kim, Se-Jong;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.151-159
    • /
    • 2011
  • Due to the Korean government's renewable energy support policy such as the renewable energy utilization building certificate and enlarging the compulsory ratio of investment on the public building, the rooftop photovoltaic projects are expanding rapidly. It is very important for the rooftop photovoltaic projects to analyze the shading effect of the adjacent structures or own facilities. But, the photovoltaic arrangements are planned by the experience of the designers or simple graphic tools. The purpose of this study is to build the process model for optimizing of rooftop photovoltaic arrangement based on three-dimensional geo-spatial information.

Effects of Drainage Types of Soil Media on the Plant Growing in Rooftop Planting (옥상녹화공법의 배수층 구조별 식물생육 효과)

  • Lee, Eun Yeob;Moon, Seok Ki
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.4
    • /
    • pp.11-21
    • /
    • 2000
  • This study was aimed to establish different drainage types of soil media on the plant growing in rooftop. For this study, experiment plots were installed on the roof of Social Science building, Chongju University, from April, 1998 to September, 1999. (1) Sand and sandy loam as base and check soils, (2) vermiculite as a inorganic soil media (3) "humus sawdust" and "burned rice hull" as organic soil media were used by various mixing ratio Zoysia japonica, was selected for the experiment. The results of this study are as follows : L5B3S2 and L5H3S2 of bad drainage character with a plastic drainage plate combination caused good growth effect on Zoysia japonica examined in 3 types of drainage layer with 5 types of soil media. From this result, it could be suggested that combined design of plastic drainage plate with 2 soil types - L5B3S2 and L5H3S2 - be desirable composition for regarding weight load and plant growth.

  • PDF

The Effect of Temperature Reduction as Influenced by Rooftop Greening (옥상녹화조성에 따른 온도저감효과에 관한 연구 -서울대학교 실험구를 중심으로-)

  • Lee, Dong-Kun;Yoon, So-Won;Oh, Seung-Hwan;Jang, Seong-Wan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.34-44
    • /
    • 2005
  • The objective of this study is to analyze the thermal properties of various green roof type. The experimental districts, have different soil thickness, soil type, the existence of module and the different kinds of vegetation, had installed. A measurement was conducted in Seoul University to investigate the thermal impacts of rooftop greening. The measurement point of temperature were 30, located in soil surface, middle of the soil layer, under the module, hard surface and soffit surface of each experimental district. The experimental investigation lasted from 6th August to 29th August, a total of 24 days. The results showed that green roof can contribute thermal benefits by soil and vegetation and reduce building energy consumption by a role of insulation. It's also better to make soil thickness over 20cm and various vegetation that should be more effective. The district installed only soil also could be effective for reducing the temperature of roof surface. Therefore, the increase of soil thickness and various vegetation could reduce more temperature of roof surface and building energy consumption. Also, it's helpful to reduce temperature that plant coverage rate be raised.

Simulation of Changes in Nearby Thermal Environment According to Green Roof in Low-Rise Residential Area of Daegu (대구광역시 저층주거지역의 옥상녹화 조성에 따른 주변 열환경 변화 모의실험)

  • Kim, Dae-Wuk;Jung, Eung-Ho;Cha, Jae-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • It is important to secure green spaces to solve the urban heat island phenomenon, which is among problems resulted by high-density developments in metropolitan areas. However, it is hard to secure such green spaces in established urban areas so Green Rooftop development approaches have recently been highlighted and introduced as a solution to the situation. The present study conducts a simulation on residential areas in urbanized regions to quantitatively evaluate the effects of green rooftop developments through a comparison of changes in the air temperatures before and after relevant development projects. According to the evaluation results, when the green roof top development is conducted in the available areas, the temperature is reduced by 0.14 degree. The extension of green project to the entire building showed the reduction of the temperature by 0.29 degree. Based on these results, it can be concluded that the green rooftop development is a practically solution for reducing the air temperature of urbanized areas.

Analysis of the Influence of Urban Land Cover Changes on the Thermal Environment of the Atmospheric Boundary Layer Using Computational Fluid Dynamics Model (전산유체역학 모델을 이용한 도시 지표 피복 변화가 대기 경계층 열적 환경에 미치는 영향 분석)

  • Kim, Ji-Seon;Yoo, Jung-Woo;Na, Mun-Soo;Kim, Yong-Gil;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1153-1170
    • /
    • 2020
  • With global warming and the rapid increase in urbanization accompanied by a concentration of population, the urban heat island effects (UHI) have become an important environmental issue. In this study, rooftop greening and permeable asphalt pavement were selected as measures to reduce urban heat island and applied to a simple virtual urban environment to simulate temperature change using ENVI-met. A total of five measures were tested by dividing the partial and whole area application of each measure. The results showed that the temperature range of the base experiment is 33.11-37.11 ℃, with the UTCI comfort level described as strong heat and very strong heat stress. A case applied permeable asphalt has a greater temperature difference than a rooftop greening case, the larger the area where each condition was applied, the greater the temperature change was.

Optimal installation of electric vehicle charging stations connected with rooftop photovoltaic (PV) systems: a case study

  • Heo, Jae;Chang, Soowon
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.937-944
    • /
    • 2022
  • Electric vehicles (EVs) have been growing to reduce energy consumption and greenhouse gas (GHG) emissions in the transportation sector. The increasing number of EVs requires adequate recharging infrastructure, and at the same time, adopts low- or zero-emission electricity production because the GHG emissions are highly dependent on primary sources of electricity production. Although previous research has studied solar photovoltaic (PV) -integrated EV charging stations, it is challenging to optimize spatial areas between where the charging stations are required and where the renewable energy sources (i.e., solar photovoltaic (PV)) are accessible. Therefore, the primary objective of this research is to support decisions of siting EV charging stations using a spatial data clustering method integrated with Geographic Information System (GIS). This research explores spatial relationships of PV power outputs (i.e., supply) and traffic flow (i.e., demand) and tests a community in the state of Indiana, USA for optimal sitting of EV charging stations. Under the assumption that EV charging stations should be placed where the potential electricity production and traffic flow are high to match supply and demand, this research identified three areas for installing EV charging stations powered by rooftop PV in the study area. The proposed strategies will drive the transition of existing energy infrastructure into decentralized power systems. This research will ultimately contribute to enhancing economic efficiency and environmental sustainability by enabling significant reductions in electricity distribution loss and GHG emissions driven by transportation energy.

  • PDF