• Title/Summary/Keyword: roller pump

Search Result 40, Processing Time 0.025 seconds

Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature (낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

Development of Speed Increaser for High Speed Machine Pump which Considered the Noise/Vibration (소음/진동을 고려한 고속머신 펌프용 증속기 개발)

  • 이동환;박노길;김병옥;이형우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.363-369
    • /
    • 2004
  • Vibration/noise analysis as well as strength of gear teeth, roller bearing life. joural bearing design are considered in order to develop the high-speed machine centrifugal pump which had a speed increaser. A Campbell diagram, in which the excitation sources caused by the mass unbalance of the rotors and the transmitted errors of the gearing are considered. shows that. at the operating speed. there are not the critical speed. A high-speed machine centrifugal pump was made in order to evaluate developed speed increaser. Also, strict API standard were introduced for reliability evaluation of developed speed increaser, and performance evaluation were carried out. The result that evaluation items about bearing vibration, shaft vibration, noise, and lubrication temperature were selected, and were tested. a high-speed machine centrifugal pump were able to know what were satisfied with API standard all.

Elastohydrodynamic Lubrication Analysis in Hydraulic Vane Pump (유압 베인 펌프에서의 탄성유체윤활 해석)

  • Park, T.J.
    • Journal of Drive and Control
    • /
    • v.10 no.3
    • /
    • pp.7-13
    • /
    • 2013
  • Hydraulic vane pumps are widely used in various hydraulic systems because of its compactness and light weight. It is well known that the vanes and cam ring are separated by very thin liquid films which result in the EHL state. Contrary to the case of cylindrical roller bearings, the inlet and side boundary pressures are much higher than the atmospheric pressure. In this paper, a numerical solution of the EHL of finite line contacts between the cam ring and vane tip with profiled ends is presented. Using a finite difference method with non-uniform grids and the Newton-Raphson method, converged solutions are obtained for moderate load and material parameters. The EHL pressure distribution and film shape are considerably affected by pump delivery pressure and the side boundary condition applied. Both the maximum pressure and the minimum film thickness always occurred near the edge regions. The present results can be used in the design of optimum vane profile in hydraulic vane pump.

A Study on the Life Characteristic of an Automotive Water-pump Bearing Using the Accelerated Test Method (가속시험법을 활용한 자동차용 워터펌프 베어링의 수명특성에 관한 연구)

  • Yang, Hui Sun;Shin, Jung Hun;Park, Jong Won;Sung, Baek Ju
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.35-41
    • /
    • 2015
  • A water-pump located in the cooling area of a car circulates cooling water. A particular bearing element, known as a water-pump bearing, installed in the rotating part carries the entire load. The failure of this water-pump bearing has a direct impact on the failure of the automobile engine, and so securing its reliability is crucial. Several researchers have examined the design principles of the water-pump bearing, but there are no reports on the life characteristic of the bearing yet. Herein, we report the construction of test equipment to reproduce the spalling of the roller contact, which is the main failure mode of the chosen water-pump bearing. We chose the radial load as an accelerated stress factor and validated the failure mode by monitoring the surface defects. We conducted the accelerated life test after determining the accelerated stress level through a combination of finite element analysis and a preliminary test. In the life tests, we used an accelerometer to perform failure diagnosis. In the last stage of this study, we present a statistical reliability analysis. Thus, we fully estimated the shape parameter of the water-pump bearing, accelerating level on the load , and the lifetime (MTTF and B10 life) under real use conditions, and finally proposed an interval estimation value considering the uncertainty of the estimated value.

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

Development of Ginseng Seeders for the Dual-use in Seedling and Direct Planting (묘삼 직파 겸용 인삼파종기 개발)

  • 이기명;박규식;김창수;김재열;김진현
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.395-402
    • /
    • 2003
  • Standard ginseng seedling, selected after one year's rearing in the seedling bed has been conventionally transplanted in Korea. Recently, the direct seeding areas have been increasing to product high quality ginsengs for red-ginseng processing. Reciprocating push-rod brush, holed-roller and vacuum suction seeders, planting with 30 ${\times}$ 30mm spacings and adjustable to the folds were designed and theirs performances were evaluated. The developed three types of seeders reliably performed at the success rate over 95% with less than 10% in slip rate, and could be used a seeder for the greater spacings by adjusting metering parts. The research concluded that the vacuum suction seeder was the most feasible and practical with the greatest metering success and the least slip among three type seeders of the reciprocating push-rod brush, holed-roller and vacuum suction seeders. The vacuum suction seeder holds a seed with each needle nozzle using the negative pressure created by a vacuum pump. The capacity was 24.5 times greater than a man power at the speed of 5 m/min.

Changes of Serum Enzyme in Open Heart Surgery (개심술 환자의 혈청효소치 변동에 관한 고찰)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 1981
  • Alterations in serum enzymes were studied in twenty-five patients who underwent open heart surgery in N.M.C. during the period from June 1979, to Feb. 1980. There were fifteen congenital and ten acquired heart diseases. In all patients, Rygg-Kyvsgaard five head roller pump and Polystan bubble oxygenator were used and serial determination of total level of Creatine phosphokinase [CPK], Lactic dehydrogenase [LDH], Glutamic oxaloacetic transaminase [SGOT] were made preoperatively, operation day [just after aortic clamp release, 2 hrs later, 4 hrs later, 6 hrs later], and postoperative days up to 5th day. Immediate postoperative clinical courses were also evaluated. Twenty-five patients were divided into two groups: Group A[13] was cardiopulmonary bypass time more than 95 minutes and aortic clamp time more than 45 minutes. Group B[12] was cardiopulmonary bypass time less than 95 minutes and aortic clamp time less than 45 minutes. The peak levels of SGOT, LDH in Group A were more significantly elevated than Group B [P<0.05]. But peak levels of CPK were not significant between two groups. In the view of clinical evaluation, poor clinical courses were more frequent in Group A [54%] than Group B[8%].

  • PDF

A study on the Optimal Condition for Application with Extracorporeal Membrane Oxygenation (ECMO 시스템 적용을 위한 최적화 조건에 관한 연구)

  • Kim, Jae-Yeol;Song, Min-Jong;You, Sin;Ma, Sang-Dong;Kim, Chang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.13-18
    • /
    • 2001
  • The ECMO system, including umbilical cord and membrane type oxygenator was connected with extracorporeal circulation unit, was applied to the fetus growth model of goat. The maximum survival time of goat fetus was 48 hours. Average blood rate for the extracorporeal circulation was $223{\pm}15.2 ml/min.$ The survival time of fetus was deeply related to body temperature, blood circulation and water temperature, anesthetized time, and fetus weights. Extern variables that are composed of anesthetized time, fetus weights, change of hemoglobin, circuit pressure, related to the survival time for fetus corrected the problem of previous ECMO model that is controlled by roller pump. It is directly delivered to heart on load. Applying the results from new ECMO model, further research will provide to the system of ECMO for human.

  • PDF

Changes of Potassium in Open Heart Surgery (개심술시의 포타시움 변화)

  • 이홍섭
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.422-427
    • /
    • 1978
  • Alterations in the serum and urine potassium were studied in twenty patients who underwent open heart surgery in National Medical Center during the period from Jan.1978 to June 1978. There were twelve cases congenital heart disease and eight acquired heart disease. Rigg-Kyvsgaad mark IV roller pump and Polystan bubble oxygenator were used in all patients. Hemodilution was carried out by priming the oxygenator with Hartmann`s solution. Measurements were made of the serum electrolyte, gas analysis and twenty four hour urine electrolytes. During the bypass, the serum potassium decreased Significantly from 4.2?.47 to 3.6?. 72 mEq. per liter. [p<0.05] Fifty seven miliequivalant of potassium chloride were added during operation-urine potassium was higher in the diuretic group than in the non diuretic group. Plasma potassium level in the diuretic group was more significantly reduced than nondiuretic group. In this series large amount of urine potassium loss was noted on the day of operation, the first and second post operative day.

  • PDF