Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass

박동류 및 비박동류에 의한 체외순환의 비교

  • Sun, Kyung (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Baek, Kwang-Je (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Kim, Yo-Han (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Kim, Chang-Young (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Kim, Kwang-Taek (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Kim, Hark-Jei (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University) ;
  • Kim, Hyoung-Mook (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University)
  • 선경 (고려대학교 의과대학 흉부외과학교실) ;
  • 백광제 (고려대학교 의과대학 흉부외과학교실) ;
  • 김요한 (고려대학교 의과대학 흉부외과학교실) ;
  • 임창영 (고려대학교 의과대학 흉부외과학교실) ;
  • 김광택 (고려대학교 의과대학 흉부외과학교실) ;
  • 김학제 (고려대학교 의과대학 흉부외과학교실) ;
  • 김형묵 (고려대학교 의과대학 흉부외과학교실)
  • Published : 1985.06.01

Abstract

[here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

Keywords