• 제목/요약/키워드: robust limits

검색결과 79건 처리시간 0.033초

지능형 디지털 재설계 기법을 이용한 비선형 전력 계통의 강인 퍼지 부하 주파수 제어 (Robust Fuzzy Load-Frequency Control of Nonlinear Power Systems Using Intelligent Digital Redesign Technique)

  • 이남수;이연우;전상원;주영훈
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 춘계학술대회 학술발표 논문집
    • /
    • pp.142-145
    • /
    • 2000
  • A new robust load-frequency control (LFC) methodology is proposed for nonlinear power systems with the valve position limits of the governor in the presence of parametric uncertainties. The Takagi-Sugeno (TS) fuzzy model is adopted for fuzzy modeling of the nonlinear power system. A sufficient condition of the robust stability is presented in the sense of Lyapunov for the TS fuzzy model with parametric uncertainties. The intelligent digital redesign technique for the uncertain nonlinear power system is also studied. The effectiveness of the proposed robust fuzzy LFC controller design method is demonstrated through a numerical simulation.

  • PDF

붓스트랩 방법을 이용한 로버스트 관리도 (Robust Control Chart using Bootstrap Method)

  • 송서일;조영찬;박현규
    • 산업경영시스템학회지
    • /
    • 제26권3호
    • /
    • pp.39-49
    • /
    • 2003
  • Statistical process cintrol is intended to assist operators of a stable system in monitoring whether a change has occurred in the process, and it uses several control charts as main tools. In design and use of control chart, it is rational that probability of false alarm is minimized in stable process and probability of detecting shifts is maximized in out-of-control. In this study, we establish bootstrap control limits for robust M-estimator chart by applying the bootstrap method, called resampling, which could not demand assumptions about pre-distribution when the process is skewed and/or the normality assumption is doubt. The results obtained in this study are summarized as follows : bootstrap M-estimator control chart is developed for applying bootstrap method to M-estimator chart, which is more robust to keep ARL when process contain contaminate quality characteristic.

유전자 알고리즘을 이용한 다중 제한 조건을 만족하는 강인 트랙 추종 제어 (A Robust Track-following Control with Multiple Constraints Using Genetic Algorithm)

  • 이문노;이홍규;진경복
    • 한국소음진동공학회논문집
    • /
    • 제22권3호
    • /
    • pp.275-283
    • /
    • 2012
  • This paper presents a design method of a robust tracking controller satisfying multiple constraints using genetic algorithm. A robust $H_{\infty}$ constraint with loop shaping is used to address disturbance attenuation with error limits and a loop gain constraint is considered so as not to enlarge the tracking loop gain and bandwidth unnecessarily. The robust $H_{\infty}$ constraint is expressed by a matrix inequality and the loop gain constraint is considered as an objective function so that genetic algorithm can be applied. Finally, a robust tracking controller can be obtained by integrating genetic algorithm with LMI approach. The proposed tracking controller design method is applied to the track-following system of an optical DVD recording drive and is evaluated through the experimental results.

유전자 알고리즘과 LMI 설계 방법을 이용한 강인 제어기의 설계 (Design of a Robust Controller Using Genetic Algorithms and LMI Design Method)

  • 이문노;이홍규
    • 제어로봇시스템학회논문지
    • /
    • 제17권7호
    • /
    • pp.619-624
    • /
    • 2011
  • This paper presents a controller design method for a robust control problem with multiple constraints using genetic algorithms and LMI design method. A robust $H_{\infty}$ constraint with loop shaping and pole placement is used to address disturbance attenuation with error limits and desired transient specifications, in spite of the plant uncertainties and disturbances. In addition, a loop gain constraint is considered so as not to enlarge the loop gain unnecessarily. The robust $H_{\infty}$ constraint and pole placement constraint can be expressed in terms of two matrix inequalities and the loop gain constraint can be considered as an objective function so that genetic algorithms can be applied. Accordingly, a robust controller can be obtained by integrating genetic algorithms with LMI approach. The proposed controller design method is applied to a track-following system of an optical disk drive and is evaluated through simulation results.

An Improvement on Target Costing Technique

  • Wu, Hsin-Hung
    • International Journal of Quality Innovation
    • /
    • 제4권1호
    • /
    • pp.191-204
    • /
    • 2003
  • The target costing technique, mathematically discussed by Sauers, only uses the $C_p index along with Taguchi loss function and $\bar{X}$-P control charts to setup goal control limits. The new specification limits derived from Taguchi loss function is linked through the $C_p value to $\bar{X}$-P control charts to obtain goal control limits. Studies have shown that the point estimator of the $C_p index, $C_p, could vary from time to time due to the sampling error. The suggested approach is to use confidence intervals, especially the lower confidence intervals, to replace the point estimator. Therefore, an improvement on target costing technique is presented by applying the lower confidence interval of the $C_p index and using both Taguchi and Spiring's loss functions together with $\bar{X}$-P charts to make this technique more robust in practice. An example is also provided to illustrate how the improved target costing technique works.

EDF 기대손실에 기초한 로버스트 공정능력지수 (A Robust Process Capability Index based on EDF Expected Loss)

  • 임태진;송현석
    • 품질경영학회지
    • /
    • 제31권1호
    • /
    • pp.109-122
    • /
    • 2003
  • This paper presents a robust process capability index(PCI) based on the expected loss derived from the empirical distribution function(EDF). We propose the EDF expected loss in order to develop a PCI that does not depends on the underlying process distribution. The EDF expected loss depends only on the sample data, so the PCI based on it is robust and it does nor require complex calculations. The inverted normal loss function(INLF) is employed in order to overcome the drawback of the quadratic loss which may Increase unboundedly outside the specification limits. A comprehensive simulation study was performed under various process distributions, in order to compare the accuracy and the precision of the proposed PCI with those of the PCI based on the expected loss derived from the normal distribution. The proposed PCI turned out to be more accurate than the normal PCI in most cases, especially when the process distribution has high kurtosis or skewness. It is expected that the proposed PCI can be utilized In real processes where the true distribution family may not be known.

LMI 기법을 이용한 시간지연 대규모 불확정성 선형 시스템의 강인 안정성 (Robust Stability of Uncertain Linear Large-scale Systems with Time-delay via LMI Approach)

  • 이희송;김진훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1287-1292
    • /
    • 1999
  • In large-scale systems, we frequently encounter the time-delay and the uncertainty, and these should be considered in the design of controller because these are the source of the degradation of the system performance and instability of system. In this paper, we consider the robust stability of the linear large scale systems with the uncertainties and the time-delays. The considered uncertainties are both structured uncertainty and the unstructured uncertainty. Also, the considered time-delays are time-varying having finite time derivative limits. Based on the Lyapunov theorem and the linear matrix inequality(LMI) technique, we present two sufficient conditions that guarantee the robust stability of the system. The conditions are expressed as the LMI forms which can be easily checked their feasibility by using the well-known LMI control toolbox. Finally, we show by two examples that our results are less conservative than the previous results.

  • PDF

로버스트 추정에 근거한 수정된 ${\bar{x}}$-s 관리도의 설계 (Design of Modified ${\bar{x}}$-s Control Chart based on Robust Estimation)

  • 정영배;김연수
    • 산업경영시스템학회지
    • /
    • 제38권1호
    • /
    • pp.15-20
    • /
    • 2015
  • Control charts are generally used for process control, but the role of traditional control charts have been limited in case of a non-contaminated process. Traditional ${\bar{x}}$-s control chart has not been activated well for such a problem because of trying to control processes as center line and control limits changed by the contaminated value. This paper suggests modified ${\bar{x}}$-s control chart based on robust estimation. In this paper, we consider the trimmed mean of the sample means and the trimmed mean of the sample standard deviations. By comparing with ARL value, the responding results are decided. The comparison resultant results of traditional control chart and modified control chart are contrasted.

위치모수를 이용한 로버스트 $\bar{x}$ 관리도의 설계 (Design of Robust $\bar{x}$ Control Chart Using a Location Parameter)

  • 정영배;김연수
    • 산업경영시스템학회지
    • /
    • 제37권1호
    • /
    • pp.151-156
    • /
    • 2014
  • Control charts are generally used for process control, but the role of traditional control charts have been limited in case of a contaminated process. Traditional $\bar{x}$ control charts have not been activated well for such a problem because of trying to control processes as center line and control limits changed by the contaminated value. This paper is to propose robust $\bar{x}$ control charts which is considering a location parameter in order to respond to contaminated process. In this paper, we consider $\bar{x}_{\alpha}$, that is trimmed rate; typically ten percent rate is used. By comparing with p, ARL value, the responding results are decided. The comparison resultant results of proposed two control charts are shown and are well contrasted.

The Robust Controller Design for Nuclear Steam Generator Using $H_{\infty}$ Control Theory

  • Yook, Seong-Hoon;Lee, Un-Chul;Park, Jung-In
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.367-373
    • /
    • 1996
  • H$_{\infty}$ robust control theory is applied to the nuclear steam generator level control. Nuclear steam generator has the properties such as nonlinearity, non-minimum phase, and so, has some difficulties on level control. In a nuclear plant, it is more important to keep the operating variables under certain safety limits against various uncertainties than to meet the optimal performance. The designed H$_{\infty}$ controller shows robust level control against modelling error, disturbance in the nonlinear simulation. As the H$_{\infty}$ controller has both robustness and design transparency, it is adequate to the automation of level control and in licensibility

  • PDF