• 제목/요약/키워드: river facility

검색결과 189건 처리시간 0.031초

군사시설물 인근지역에서의 퍼클로레이트 오염수준 및 특성 (Characteristics of Level of Perchlorate Pollution near Military Facility Areas)

  • 최진수;엄철용;주경훈;함석헌;이종혁;유성수;고광백
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.460-466
    • /
    • 2012
  • Perchlorate is used in a number of applications as an oxidizer in solid propellants, munitions and fireworks and is one of the endocrine disrupting chemicals, which interferes with iodide uptake into the thyroid gland. The purpose of this study was to investigate perchlorate occurrence and distribution with a results of analysis of 94 samples collected from military facilities in Korea from October 11 to October 23, 2011. Overall, among all of the 94 samples analyzed, perchlorate was detected in 6.4% of the total number of samples above $4{\mu}g/L$ (minimum reported limit) and the average concentration was $26.1{\mu}g/L$ and the maximum concentration was $107.7{\mu}g/L$ which was observed in surface water near manufacturing site of ammunition. By site classification, perchlorate was detected at one site in 4 manufacturing sites of ammunition and the maximum concentration was $107.7{\mu}g/L$ which was six times higher than that in guideline for perchlorate in Nakdong River and resulted from point source discharge. Perchlorate was detected at 3 sites in 78 measurements for shooting area and the maximum concentration was $12.4{\mu}g/L$ which was collected in dringking water and perchlorate in another sample was detected above MRL in shooting area was collected right away after shooting. These results showed that long term monitoring was needed considering weather conditions and shooting schedules.

GIS를 이용한 미호천의 장래수질예측 (Water Quality Prediction of the Miho Stream Using GIS)

  • 노준우;이상진;이상욱
    • 대한공간정보학회지
    • /
    • 제16권1호
    • /
    • pp.13-21
    • /
    • 2008
  • 본 논문에서는 금강수계의 미호천을 대상으로 GIS를 이용, 2010년을 대상으로 장래수질을 예측하였다. 오염총량관리 기본계획에서 제시된 자료를 기반으로 미호천으로 유입되는 지류별 수계에 대하여 재계산하여 각 수계별 오염부하량을 산정하였으며 이들 정보를 활용하여 지류별 농도를 계산한 다음 미호천의 수질모의를 실시하였다. 수질모의는 대표적인 하천수질 모형인 Qual2E 모형을 사용해서 BOD, TN, TP 등의 대표적인 수질인자에 대한 모의를 실시 하였다. 수계별 오염부하량을 산정한 결과 도시지역을 포함한 무심천 및 보청천의 부하량이 높게 나타남을 알 수 있었고 미호천 전체 수질은 청주 하수처리장의 영향을 직접적으로 받는 것으로 나타났다. 대상유역에서의 효율적 수질관리와 오염총량제에서 제시한 목표수질을 달성하기 위해서는 하수처리장의 고도처리화가 먼저 달성되어야 함을 알 수 있었고, 그 외에도 무심천으로 공급되는 농업용수의 유량을 증가시켜 이를 수질희석의 용도로 사용하는 방안에 대해서 모의를 실시함으로써 수질기준을 만족할 수 있는 적정유량을 산정하여 제시하였다.

  • PDF

고로슬래그 콘크리트의 투수특성에 관한 실험적 연구 (An Experimental Study on Permeability Characteristics of Blast Furnace Slag Concrete)

  • 백신원;오대영
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.9-12
    • /
    • 2013
  • The pavement is generally used on the highways, local loads, roads for bicycle riding and neighborhood living facility such as parking lot, plaza, park and sports facilities. However, the pavement material that is usually used on the most of roads is impermeable asphalt-concrete and cement-concrete. If the pavement material is impermeable, many problems can be happened on the drainage facilities in the rainy season. Additionally, a lot of rainwater on the pavement surface cannot permeate to the underground and flows to the sewage ditch, stream and river, etc. If a lot of rainwater flows at once, the floods can be out along the streams and rivers. So, underground water can be exhausted. Micro organisms cannot live in the underground. Recently, many studies has been conducted to exploit the permeable concrete that has high performance permeability. However, it is required to develop the permeable concrete which has high strength and durability. In this study, permeable and strength tests were performed to investigate the permeable characteristics of porous concrete according to fine aggregate content and substitution ratio of blast furnace slag. In this test, crushed stones with 10~20 mm and sand with 5~10 mm were used as a coarse aggregate and a fine aggregate respectively. The substitution ratio of blast furnace slag to cement weight is 0 %, 15 %, and 30 %. The ratio of fine aggregate to total aggregate is 0 %, 18 %, and 35 %. As a result, permeability coefficient was decreased according to fine aggregate ratio of total aggregate. Compressive strength was also decreased according to substitution ratio of blast furnace slag.

도시공간을 고려한 야간시간대의 열섬특성 분석 (Analysis of Heat Island Characteristics Considering Urban Space at Nighttime)

  • 송봉근;박경훈
    • 한국지리정보학회지
    • /
    • 제15권1호
    • /
    • pp.133-143
    • /
    • 2012
  • 본 연구는 창원시 도시지역을 대상으로 도시공간을 고려한 야간시간대의 도시열섬특성을 파악하기 위해 1:1,000 축척의 토지이용도 및 토지피복도와 DTM, 그리고 ASTER 위성영상에서 추출된 야간시간대의 지표온도자료를 활용하였다. 분석결과에 따르면, 야간시간대는 건물이 밀집되어있는 단독주거지역이 상업지역이나 공공시설지역보다 열섬강도가 높았고, 이것은 에너지소비에 의한 인공열 방출이 열섬형성에 많은 영향을 미치기 때문으로 판단된다. 또한 이러한 점 때문에 공업지역에서는 건물은 가동시간에 따라 온도차이가 매우 크게 나타났다. 한편, 도시녹지지역과 하천지역은 도시열섬을 완화하는 냉각효과가 있는 것으로 확인되었으며, 열섬강도가 높은 지역에 녹지 및 수변공간의 조성으로 열섬강도를 낮출 필요가 있을 것으로 판단된다. 이상과 같은 결과는 야간시간대의 도시열섬을 완화하는데 있어 개발계획 수립시 효율적인 공간활용을 위해 기초자료로 이용될 것으로 사료된다.

농촌지역 마을의 개발수요에 관한 연구 -농촌마을종합개발사업 예비계획서 분석을 통해- (A Study on the Demand of Development in the Villages of Rural Areas - Focused on the Analysis of Preliminary Plans about Rural Community Development Project -)

  • 조원석;유영모
    • 한국농촌건축학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-28
    • /
    • 2011
  • This paper was able to indicate to the results the following thing that attempted a required potential development demand, through the contents and cost analysis in Rural Community Development Project. Nowadays, Rural Areas comparatively have a lot of development demands related to improvements environmental of residence life and construction of Urban-Rural Exchange Facility, on the other and, there is comparatively a few facilities demands regarding agriculture production. Demand is cold storage facilities and agricultural products direct sale facilities expansion to be able to raise value added of agricultural products as facilities related comparatively a little agriculture production, and an improvement of residence life comparatively has a lot of repair environmental uninhabited house repair, river-front and the roadside, rest shelter creation demands. However, that should be forecasted so that aging of rural, population decrease and development demand is caused by a lot of issues such as maintenances operation of many Urban-Rural Exchange Facilities and a similar program and content has a lot of them in bilateral adjacent zones. Therefore, in the future plan shall attempt efficiency operating facilities and a program through characterization and network of zone so that facilities and program can have complementary relation in the adjacent zones. And item development and an investor are necessary regarding new labor force supply for continuous value maintenance of space and returning to the farm that there were the reverse agriculture production and Amenity which are an rural village. Furthermore, developmental plan of rural village is necessary through the demand analyses that a citizen wishing for things.

안양천의 계절별 수질분석 (Analyses of Seasonal Water Quality of The Anyang Stream)

  • 한중근;이양규;남정만
    • 한국환경복원기술학회지
    • /
    • 제7권4호
    • /
    • pp.52-60
    • /
    • 2004
  • In order to analysis of the water pollution of the Anyang stream(one of the biggest branch streams of the Han River) and its main tributaries, the geological and topographical and rainfall features in its basin were investigated. To do this, the water samples were collected 23 points of the upper, mid and down of Anyang stream and its tributaries and were analyzed based on the chemical methods, Korean Biotic Index(KBI) and Saprobien systems. The Anyang stream basin has a characteristic of topographical torrential heavy rainfall like a typical rainfall feature in Korea. The concentration and the outflow rate of rainfall is very different in seasonal, and water pollution in dry season is especially severe. After 1997, although the water quality status of stream has been improved gradually, the concentration of T-N and SS at the upstream is increased due to the deficiency of facility used for collecting wastewater released from industrial factories, livestock farms and residential areas. The mainstream of the Anyang stream is classified into the 5th grade water as polysaprobic water area according to Saprobien system and the biotic index is over 2.5 in overall. Most of tributaries have 1~3 grade water limit with ${\alpha}$- and ${\beta}$-mesosaprobic except the upper and mid streams of Samsung tributary, in which pollution status is the lowest part. Though Sambong tributary is ${\alpha}$-mesosaproboic, biotic index is low because of the appearance of abundant benthos animals in farming and fishing villages.

에어버블 차단막을 이용한 발전플랜트 피해 저감 방안 연구 (The Damage Reduction Strategy for Power Plant Using Air Bubble Barrier)

  • 장형준;이호진;이효상;황명규
    • 한국방재안전학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2018
  • 발전소는 선진 산업사회에서의 중요한 사회기반시설이다. 이러한 발전소가 해초, 물고기, 해파리, 새우 등과 같은 해양생물의 유입으로 정지 될 경우, 사회-경제적으로 심각한 문제가 발생하기도 한다. 따라서, 발전소 취수구 유입구 부분의 해양생물 침투로 인한 발전소 가동이 정지되는 것을 방지하기 위하여, 에어버블 차단막 기술이 활용되고 있다. 본 연구에서는 에어버블 차단막 기술의 기초연구인 에어버블의 거동을 분석하기 위하여 수직형 에어버블 실험장치를 개발 및 에어버블수직 거동 특성을 분석하였다. 에어버블 수직 거동 특성을 분석하기 위하여 수직형 에어버블 실험 장치를 이용하여 에어 분사량에 따른 수심별 에어버블의 상승 속도를 측정하였으며, 실험결과를 바탕으로 수심구간별 에어버블 상승속도 경험식을을 제시하였다. 제시된 경험식은 향후 에어버블 차단막 설계의 기초자료로 활용될 것이며, 발전시설 운영 부분에서의 안정성을 확보하는 데 크게 기여할 것으로 기대된다.

월류부특성변화에 따른 천변저류지군의 홍수저감효과분석 (Analysis of Flood Reduction Effect of Washlands based on Variation of Rollway Characteristic)

  • 백천우;김복천;안태진
    • 한국방재학회 논문집
    • /
    • 제9권1호
    • /
    • pp.145-150
    • /
    • 2009
  • 댐과 같은 대규모 수리구조물의 신설이 점차 어려워짐에 따라, 이에 대한 대안으로 천변저류지의 설치가 검토되고 있다. 천변저류지는 규모가 작은 시설물로 홍수량, 유입수문곡선, 천변저류지 용량 및 월류위어의 월류고 등에 따라 홍수저감효과가 민감하게 반응한다. 따라서 최대의 홍수저감효과를 얻기 위해서는 홍수저감효과를 기대하는 홍수사상에 적합한 월류고를 적용하여야 하며, 본 연구에서는 월류고 값의 변화가 천변저류지군의 홍수저감효과에 미치는 영향을 분석해보았다. 이를 위해 천변저류지의 최적위치를 결정하기 위해 개발된 기존의 의사결정모형을 사용하였다. 천변저류지의 위치를 결정변수로 사용하고 홍수저감목표 지점에서의 홍수저감효과를 최대화하는 과정을 통해 천변저류지의 최적위치를 결정하는 의사결정모형에 월류고의 높이를 결정 변수로 추가하여 수정하였다. 제안된 모형을 안성천 유역에 적용하여 기존의 연구결과와 비교하였으며, 모형의 적용결과 대상 홍수사상에 대해 보다 효율적인 홍수저감이 가능토록 하는 월류고 및 위치를 결정 할 수 있었다.

생태저류지 LID 시설의 설계 및 평가를 위한 삭감대상부하비 산정방법 개선 (mprovement of Estimation Method of Load Capture Ratio for Design and Evaluation of Bio-retention LID Facility)

  • 최정현;이옥정;김용석;김상단
    • 한국물환경학회지
    • /
    • 제34권6호
    • /
    • pp.569-578
    • /
    • 2018
  • To minimize the negative alterations in hydrologic and water quality environment in urban areas due to urbanization, Low Impact Development (LID) techniques are actively applied. In Korea, LID facilities are classified as Non-point Pollution Reduction Facilities (NPRFs), and therefore they are evaluated using the performance evaluation method for NPRFs. However, while LID facilities are generally installed in small, distributed configuration and mainly work with the infiltration process, the existing NPRFs are installed on a large scale and mainly work with the reservoir process. Therefore, some limitations are expected in assessing both facilities using the same method as they differ in properties. To solve these problems, in this study, a new method for performance evaluation was proposed with focus on bio-retention LID facilities. EPA SWMM was used to reproduce the hydrologic and water quality phenomena in study area, and SWMM-LID module used to simulate TP interception performance by installing a bio-retention cell under various conditions through long-term simulations. Finally, an empirical formula for Load Capture Ratio (LCR) was derived based on storm water interception ratio in the same form as the existing method. Using the existing formula in estimating the LCR is likely to overestimate the performance of interception for non-point pollutants in the extremely low design capacity, and also underestimate it in the moderate and high design capacity.

도시특성이 건축물의 탄소배출에 미치는 영향에 관한 연구: 서울시 424개 행정동에 대한 공간회귀분석의 적용 (The Impact of Urban Characteristics on Carbon Emissions of Buildings in Seoul: Application of Spatial Regression Analysis)

  • 조항훈;김흥순
    • 토지주택연구
    • /
    • 제14권3호
    • /
    • pp.77-92
    • /
    • 2023
  • 본 연구는 건축물에서 발생하는 탄소배출량에 영향을 미치는 도시특성 요인을 분석하였다. 2021년 서울시 에너지정보 플랫폼에서 구득한 건축물에서 사용된 에너지와 탄소배출량을 이용하여 424개 행정동 단위의 분석을 실시하였다. 종로와 강남, 구로와 목동 등지에서 단위 건물면적당 탄소배출량이 큰 것으로 나타났다. 공간시차모형(SLM)을 이용하여 회귀분석을 실시한 결과, 건물의 탄소배출량에 영향을 미치는 변수는 건조환경요인의 상업, 교육, 업무, 공업시설 변수와 인구요인의 생활인구, 교통시설 요인의 통행량, 버스노선 수, 지하철역 수, 환경요인의 녹지면적과 하천면적으로 파악되었다.