• Title/Summary/Keyword: risk assessment tool

Search Result 469, Processing Time 0.029 seconds

A study on the Research & Analysis of the Health and safety Managing's Understanding for practical Application of Construction Industry Risk Assessment - Focus on worker - (건설업 위험성평가 실무적 적용을 위한 안전보건 인식도 조사 연구 -근로자를 중심으로-)

  • Choe, Su-Hwan;O, Tae-Geun;Lee, Yeon-Su;Lee, Jin-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.445-456
    • /
    • 2013
  • According to Department of labor guideline "2012-104 (2012.9.26.)" This study is to suggest the basic information and the improvement for the application of risk assessment on a construction site by group interview & survey of construction worker who is the practice of the subject and then numerical analysis about awareness and action plan of Safety and health. The result of group interview and survey of construction worker, most of construction worker feel the danger during the work. Then construction worker analysis results that risk assessment helps to change & raise awareness of safety and reduce an industrial disaster. Easy Safety management activity such as TBM & safety education active will be necessary for safe worksite and then I suggest the TBT(tool box talk) active which combines TBM & safety education.

  • PDF

Evaluation of the Application of a European Chemical Risk Assessment Tool in Korea (외국 노출량 산정 프로그램(ECETOC TRA)의 국내 적용을 위한 입력변수의 보정에 관한 연구)

  • Lee, Jong Han;Lee, Kown Seob;Hong, Mun Ki
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.191-199
    • /
    • 2012
  • Objectives: The study aim was to evaluate the application of a chemical exposure assessment tool for the Korean workplace. The Ministry of Employment and Labor in Korea (KMOEL) introduced the need for workplace risk assessments in 2011, requiring the Korean chemical industry to consider both domestic and international chemical regulation policies (e.g., estimations of exposure scenarios). Exposure scenarios are required in the European Union as part of material safety data sheets (MSDS) under the Registration, Evaluation, Authorization, and Restriction of Chemicals (REACH) system. Methods: Although many programs for the estimation of exposure have been developed worldwide, to date there is no standard for the Korean workplace. To develop programs suitable for the Korean workplace, we examined the applicability of the European Center for Ecotoxicology and Toxicology of Chemicals target risk assessment (ECETOC TRA), which is recommended by the European Chemical Agency (ECHA). Results: To investigate the applicability of the ECETOC TRA to Korean industry, this study simulated 15 industrial processes. The predicted respiratory exposures for four processes using origin input parameters were underestimated compared to the measured respiratory exposure. Using calibrated input parameters, results for two processes were underestimated compared to the measured respiratory exposure. This result suggests that the use of calibrated input parameters reduces the differences between predicted and measured respiratory exposure. Conclusions: we developed applicable exposure estimating method by modifying the ECETOC TRA program; one suggested the development of exposure estimating program that explains Korea domestic workplace exposure scenario.This study will support the introduction of exposure scenario in MSDS system and protect health of worker from hazardous chemical.

Application of Probabilistic Health Risk Analysis in Life Cycle Assessment -Part I : Life Cycle Assessment for Environmental Load of Chemical Products using Probabilistic Health Risk Analysis : A Case Study (전과정평가에 있어 확률론적 건강영향분석기법 적용 -Part II : 화학제품의 환경부하 전과정평가에 있어 건강영향분석 모의사례연구)

  • Park, Jae-Sung;Choi, Kwang-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.203-214
    • /
    • 2000
  • Health risk assessment is applied to streamlining LCA(Life Cycle Assessment) using Monte carlo simulation for probabilistic/stochastic exposure and risk distribution analysis caused by data variability and uncertainty. A case study was carried out to find benefits of this application. BTC(Benzene, Trichloroethylene, Carbon tetrachloride mixture alias) personal exposure cases were assumed as production worker(in workplace), manager(in office) and business man(outdoor). These cases were different from occupational retention time and exposure concentration for BTC consumption pattern. The result of cancer risk in these 3 scenario cases were estimated as $1.72E-4{\pm}1.2E+0$(production worker; case A), $9.62E-5{\pm}1.44E-5$(manger; case B), $6.90E-5{\pm}1.16E+0$(business man; case C), respectively. Portions of over acceptable risk 1.00E-4(assumed standard) were 99.85%, 38.89% and 0.61%, respectively. Estimated BTC risk was log-normal pattern, but some of distributions did not have any formal patterns. Except first impact factor(BTC emission quantity), sensitivity analysis showed that main effective factor was retention time in their occupational exposure sites. This case study is a good example to cover that LCA with probabilistic risk analysis tool can supply various significant information such as statistical distribution including personal/environmental exposure level, daily time activity pattern and individual susceptibility. Further research is needed for investigating real data of these input variables and personal exposure concentration and application of this study methodology.

  • PDF

Korean Caries Management by Risk Assessment (K-CAMBRA) (임상가를 위한 특집 1 - 우식위험도평가에 근거한 한국형 치아우식증 관리 모델)

  • Kim, Baek Il
    • The Journal of the Korean dental association
    • /
    • v.52 no.8
    • /
    • pp.456-463
    • /
    • 2014
  • Caries Management by Risk Assessment (CAMBRA), published by California Dental Association in 2003, is a customized caries care system that classifies individuals' caries risk into 4 risk groups based on objective evidences and provides chemical treatments targeted for each caries risk level. However, this system was not only developed but also optimized for situation in the United States, resulting into many limitations to be used in Korea, and thus Korean CAMBRA (K-CAMBRA) that considers the clinical situation in Korea needs to be developed. K-CAMBRA includes various techniques that are newly developed in order to overcome the limitations. First, Q-ray, a new optical technology, is utilized in order to avoid the subjectivity of visual inspection during assessment of disease indicators and risk factors. Moreover, Cariview? that reflects the paradigm shift in cariology as a new form of caries assessment kit is used. In addition, considering the situation in Korea, where it is impossible to use high concentration fluoride product, Oral pack with a customized tray is added to increase the contact time of chemical substance. CAMBRA is believed to be the key clinical tool that overcomes the limitations of the paradigm of the conventional restoration-based surgical model of dentistry. Furthermore, it can be expected that Korean dentists can act as oral physicians who are able to control and care individuals' caries risk rather than operative experts who only care about the outcome of caries.

Risk Assessment of exposure to the extinguishing agents using CHARM (CHARM을 통한 소화약제 위험성 평가에 관한 연구)

  • Cho, Jung Rae;Jung, Tae Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.35-41
    • /
    • 2017
  • Recently chemical intoxication related with the use of chemical extinguishing agents occurs frequently. With the industrialization, high-rising of building and increase of fire risk, we use the various extinguishing agents and the safe use become important. In this study I carried out the risk assessment of representative chemical extinguishing agents (HCFC-123, HFC-125) using the CHARM and got the meaningful qualitative outcome. This study is significant in that the risk assessment of chemicals was conducted using CHARM, chemical risk assessment tool. It is expected that the results will be utilized as the basic data for the national chemical safety management.

Validation of Fall Risk Assessment Scales among Hospitalized Patients in South Korea using Retrospective Data Analysis (후향적 자료분석을 통한 낙상위험 사정도구의 타당도 비교: 종합병원 입원 환자를 중심으로)

  • Kang, Young Ok;Song, Rhayun
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.1
    • /
    • pp.29-38
    • /
    • 2015
  • Purpose: The purpose of the study was to validate fall risk assessment scales among hospitalized adult patients in South Korea using the electronic medical records by comparing sensitivity, specificity, positive predictive values, and negative predictive values of Morse Fall Scale (MFS), Bobath Memorial Hospital Fall Risk Assessment Scale (BMFRAS), and Johns Hopkins Hospital Fall Risk Assessment tool (JHFRAT). Methods: A total of 120 patients who experienced fall episodes during their hospitalization from June 2010 to December 2013 was categorized into the fall group. Another 120 patients, who didn't experience fall episodes with age, sex, clinical departments, and the type of wards matched with the fall group, were categorized to the comparison group. Data were analyzed for the comparisons of sensitivity, specificity, positive and negative predictive values, and the area under the curve of the three tools. Results: MFS at a cut-off score of 48 had .806 for ROC curves, 76.7% for sensitivity, 77.5% for specificity, 77.3% for positive predictive value, and 76.9% for negative predictive value, which were the highest values among the three fall assessment scales. Conclusion: The MFS with the highest score and the highest discrimination was evaluated to be suitable and reasonable for predicting falls of inpatients in med-surg units of university hospitals.

Microbial Modeling in Quantitative Risk Assessment for the Hazard Analysis and Critical Control Point (HACCP) System: A Review

  • Min, Sea-Cheol;Choi, Young-Jin
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.279-293
    • /
    • 2009
  • Quantitative risk assessments are related to implementing hazard analysis and critical control points (HACCP) by its potential involvement in identifying critical control points (CCPs), validating critical limits at a CCP, enabling rational designs of new processes, and products to meet required level of safety, and evaluating processing operations for verification procedures. The quantitative risk assessment is becoming a standard research tool which provides useful predictions and analyses on microbial risks and, thus, a valuable aid in implementing a HACCP system. This paper provides a review of microbial modeling in quantitative risk assessments, which can be applied to HACCP systems.

The Assessment of the Risk Index in the Bridge Construction by the AHP Method (AHP기법을 이용한 교량공사 위험지수 평가)

  • Lee, Myeong-Gu;Jeong, Myeong-Jin;Kim, Kyu-Dong;Choi, Soon-Ju;Park, Seung-Kook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.119-123
    • /
    • 2009
  • The purpose of this study is to verify the assessment of the risk index by the AHP method effective in the bridge construction. We compared that by the AHP method with the risk index by the accident analysis in the bridge construction. This method results in the useful tool deciding the assessment of the risk index according to work type in the bridge construction.

The Application of an EU REACH Protocol to the Occupational Exposure Assessment of Methanol: Targeted Risk Assessment (메탄올 작업장 노출 평가에의 EU REACH 프로토콜 적용: Targeted Risk Assessment)

  • Ra, Jin-Sung;Song, Moon Hwan;Choe, Eun Kyung
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.432-445
    • /
    • 2021
  • Background: The European Centre for Ecotoxicology and Toxicology of Chemicals' Targeted Risk Assessment (ECETOC TRA) tool has been recognized by EU REACH as a preferred approach for calculating worker health risks from chemicals. Objectives: The applicability of the ECETOC TRA to occupational exposure estimation from industrial uses of methanol was studied by inputting surveyed and varied parameters for TRA estimation as well as through comparison with measured data. Methods: Information on uses of methanol was collected from seven working environment monitoring reports along with the measured exposure data. Input parameters for TRA estimation such as operating conditions (OCs), risk management measures (RMMs) and process categories (PROCs) were surveyed. To compare with measured exposures, parameters from the surveyed conditions of ventilation but no use of respiratory protection were applied. Results: PROCs 4, 5, 8a, 10, and 15 were assigned to ten uses of methanol. The uses include as a solvent for manufacturing sun cream, surfactants, dyestuffs, films and adhesives. Methanol was also used as a component in a release agent, hardening media and mold wash for cast products as well as a component of hard-coating solution and a viscosity-controlling agent for manufacturing glass lenses. PROC 8a and PROC 10 of a cast product manufacturer without LEV (local exhaust ventilation) and general ventilation as well as no respiratory protection resulted in the highest exposure to methanol. Assuming the identical worst OCs and RMMs for all uses, exposures from PROC 5, 8a, and 10 were the same and the highest followed by PROC 4 and 15. The estimation resulted in higher exposures in nine uses except one use where measured exposure approximated exposures without RMMs. Conclusions: The role of ECETOC TRA as a conservative exposure assessment tool was confirmed by comparison with measured data. Moreover, it can guide which RMMs should be applied for the safe use of methanol.

Nutrition Evaluation Screening Tool: An Easy to Use Screening Tool for Hospitalised Children

  • Dokal, Kitt;Asmar, Nadia;Shergill-Bonner, Rita;Mutalib, Mohamed
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.1
    • /
    • pp.90-99
    • /
    • 2021
  • Purpose: Nutrition screening is vital to ensure patients are appropriately managed in hospital. In paediatrics there is currently no universally accepted nutrition screening tool. The Nutrition Evaluation Screening Tool (NEST) was developed as an easy to use and practical screening tool for hospitalised children. We aim to evaluate compliance of the NEST and assess agreement of the NEST with the already validated nutrition screening tools, Screening Tool for Risk on Nutritional Status and Growth (STRONGkids), Screening Tool for the Assessment of Malnutrition in Paediatrics (STAMP) and the Subjective Global Nutritional Assessment (SGNA) tool. Methods: Retrospective review of 102 patient episodes at the Evelina London Children's Hospital. Electronic records were used to assess NEST compliance and to complete the nutrition tools for each patient episode. Cohen's kappa was used to determine the level of agreement between each nutrition tool. Results: There was moderate agreement between the NEST and the two screening tools, STRONGkids (κ=0.472) and STAMP (κ=0.416) for patients on initial screening at admission. 87.2% of patient episodes were NEST compliant within 24 hours of admission to hospital. Conclusion: The moderate agreement between these two already validated screening tools enhances the NEST's validity as a paediatric screening tool. The NEST had the strongest correlation with the SGNA tool compared to other screening tools. The NEST is user friendly screening tool for hospitalised children.