• Title/Summary/Keyword: rinsing

Search Result 230, Processing Time 0.033 seconds

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using Bigh Performance Polymer Membranes ( I ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성 (I))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.3 s.82
    • /
    • pp.34-42
    • /
    • 2005
  • In this work, a practical separation performance was investigated on aqueous alcohol solutions, especially for iso-propyl alcohol (IPA), which is usually used during the semi- conductor rinsing process. The removal of various substances from waste aqueous IPA solutions was carried out by microfiltration with $0.1\~1{\mu}$m pore size of mean diameter as a pre-filter. Permeability and molecular weight cut-off of the functional polysulfone(PSf) ultrafiltration membrane to purify waste aqueous IPA solutions were measured through the ultrafiltration test. The solute rejection of PSf membrane had $92\%$ in 1,000ppm aqueous PEG solution with PEG molecular weight 10,000, the molecular weight cut-off had 10,000. The IPA concentration on the $CMPA-K^+$ membrane performance using pervaporation module system could be increased from $95.04 wt\%$ to more than $98.50wt\%$ in about 9hr at operation temperature of $70^{\circ}C$ using the pervaporation module system.

Hair Damage and Wave Shape according to Dyeing, Bleaching, Permanent Wave Treatment (염.탈색 및 펌 처리에 따른 모발의 손상과 웨이브 형상)

  • Kweon, Soo-Ae;Roh, Joung-Ae;Park, Yong
    • Korean Journal of Human Ecology
    • /
    • v.15 no.6
    • /
    • pp.1083-1089
    • /
    • 2006
  • In this paper, the damage of hair and wave shape in process of the dyeing, bleaching, and permanent hair wave are simulated. The virgin hair that do not process the dyeing, bleaching, and permanent hair wave becomes stable in the scale type. On the other hand, the hair that deals with the dyeing, bleaching, and permanent hair wave is heavily damaged in the scale type. It is observed that the higher pH is decided, the higher the hair is damaged because the scale damage in the bleaching hair is more heavily damaged than the dyeing hair. In case of executing the permanent hair wave, the processing of the plaine rinsing becomes less in the scale damage of the hair and better in the wave form. Therefore, it is found that the processing of the plaine rinsing to improve the wave form and to prevent the hair damage is needed.

  • PDF

Development of Multi Sample Array System Based on Pneumatic Valve (공압식 미세밸브를 이용한 다중유체 배열장치 개발)

  • Kim, Chul Min;Park, Seo Jung;Kim, Gyu Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.1
    • /
    • pp.59-63
    • /
    • 2017
  • We present a multi-sample array device based on a pneumatic system. Solenoid valves were used to control a micro valve in a pneumatic system. The use of a compressor together with a vacuum pump ensured that one outlet could supply both compression and vacuum pressure. The multi-sample array device was fabricated using conventional photolithography and PDMS casting. The device was composed of a multiplexer, sample array, and rinsing. The multiplexer could control four sample solutions injecting into the sample array chamber. Sample solution not arrayed was removed by DI-water from the rinsing inlet. To prevent trapping of microbubbles in the channel during injection of sample solution into the device, surfactant was added in PDMS solution to serve as a hydrophilic surface treatment. As a result, the device could be used as a sample array for 64 cases, using four samples and three columns of three chambers.

Analysis of Electrical Conductivity during Desalinization of Reclaimed Tidal Lands (간척지 토양의 제염과정 중 전기전도도 분석)

  • 구자웅;최진규;손재권;윤광식;이동욱;조경훈
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.4
    • /
    • pp.37-49
    • /
    • 2001
  • This study was performed in order to produce the basic data for developing prediction techniques of desalinization to be applicable to reclaimed tidal lands at the beginning stage. the desalinization experiments were carried out by two water management practices, namely, the leaching method by subsurface drainage and the rinsing method by surface drainage. The 5 soil samples used in this study were collected in 4 tidal land reclamation projects. Regression equations were obtained in order to investigate the changes of electrical conductivity during the desalinization of reclaimed tidal lands and to estimate water requirements for desalinization. The results obtained from this study were summarized as follows: 1. According to USDA Salinity Laboratory classification system of salt affected soils the reclaimed tidal land soils used in this study were saline-sodic soils with the high electrical conductivity and the high exchangeable sodium percentage. 2. With the increase of the water requirements for desalinization the electrical conductivity was decreased with high degree of correlationships and the desalinization effects were remakable in both the leaching method and the rinsing method. 3. In case of the leaching method the electrical conductivity had been reduced below the classification value of salt affected soils when the depth o water leached per unit depth of soil (Dwl/Ds) was 0.3 and the desalinization effects showed a tendency to be much the same in each treatment.

  • PDF

Improved Cleaning Method for Dental Instruments

  • Kim, In-Geol;Lee, Yun-Ji
    • Journal of Korean Dental Science
    • /
    • v.3 no.2
    • /
    • pp.26-33
    • /
    • 2010
  • We searched at the "PubMed.gov" and "jendodon.com" sites to conduct a literature review on dental instruments that are reused in clinical settings and on infection control involving pre-disinfection or sterilization cleaning/rinsing. The keyword "dental clean" was used for the Web search. We found the present official definition of instrument cleaning performed prior to disinfection or sterilization rather limiting ("removal of foreign matter (soil, organism, etc.) from the instruments"). Thus, we proposed to expand the definition to include the removal of oils applied to protect the metallic instruments and from corrosion, stains, and rust resulting from the frequent reuse of the instruments. Clinicians are found to clean their dental instruments (a) immediately after treating their patients or (b) following their treatment but not immediately afterward. In the latter case, we recommend presoaking to be added. Ultrasonic sterilization of 5~15 minutes is found to be more effective in terms of eliminating residual matter from the instruments compared to other methods. To check on the cleaning results, we recommend visual inspection, which can be quick and practical in clinical settings. The latest products being developed and marketed on the market address the related problems. Nonetheless, research must be continued on the effects of presoak, cleaning/rinsing, disinfection, and high-temperature or heating-based sterilization on the dental instruments and on dental clinicians' practices in cleaning, disinfection, and sterilization. We advise dental clinicians to select the proper cleaning methods and detergents for their instruments to help eliminate or prevent corrosion, staining, and rusting, to reduce the maintenance costs, and to ensure user-friendly instruments/apparatuses.

  • PDF

STUDIES ON THE EFFECT OF WEEKLY SELF APPLICATION WITH SODIUM FLUORIDE SOLUTION (불소자가도포의 치아우식증 예방효과에 관한 연구)

  • Jung, In-Whan
    • The Journal of the Korean dental association
    • /
    • v.16 no.8 s.111
    • /
    • pp.619-624
    • /
    • 1978
  • The use of mouth-rinses containing sodium fluoride after tooth brushing has been proposed as a potentially useful measure for the prevention of dental caries in the practice of public health. About 700 middle school girls rinsed their mouths in the school once a week with sodium fluoride sodution after tooth-brushing. Tooth brushing was practiced everyday after meals and the rinses were carried out under the supervision of the teachers. The procedure consisted of gargling 10cc of fluoride solution for one minute and immediately followed by a second rinse with tap water. The rinsing was started in May 1976 and continued for one year. The results were as follows: 1) The inhibition of the 'D' Person rate was 76.04%, 'M' person rate was 80.79%, 'F' person rate was 4.06% and, 'D.M.F.' person rate was 76.86%. 2) the reduction of the 'D.T.' Index was 81.94%, 'M.T.' Index was 85.71%, 'F.T.' Index was 7.69% and, 'D.M.F.T.' Index was 76.83%. 3) Mouth rinsing with 0.3% NaF solution and tooth brushing are of value in the mass control of dental caries.

  • PDF

Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -I. Permeation Characteristics of Polysulfone Flat Plate Membrane- (Si 입자를 함유한 반도체 세정폐수의 한외여과 특성[I] -Polysulfone 평판막에 의한 투과분리-)

  • 곽순철;이석기;전재홍;남석태;최호상
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 1998
  • Permeation behavior of the semiconductor rinsing wastewater containing Si particles was examined by ultrafiltration using the polysulfone plate membrane. The permeation flux was gradually decreased with time. It was due to the growth of cake deposited on the membrane surface and the pore plugging by Si particles. Permeation flux of cross flow type was 1.4 times higher than that of the dead end flow type. Nitrogen back flushing which is the removing method of membrane fouling was superior to the water sweeping. With nitrogen back flushing, the decrease of permeation flux due to the fouling was recovered about 85 % to the initial flux in the flat plate membrane system. The rejection rate of Si particles was about 90 % and the size of Si particle in the permeate was about 70 nm.

  • PDF