• Title/Summary/Keyword: rigid tray

Search Result 6, Processing Time 0.021 seconds

Packaging technology of fresh-cut produce (신선편의식품 포장기술)

  • Kim, Ji Gang
    • Food Science and Industry
    • /
    • v.50 no.2
    • /
    • pp.12-26
    • /
    • 2017
  • Processing steps such as washing and cutting, involved in preparing fresh-cut produce causes tissue damage, leading to rapid quality deterioration. Major defects of fresh-cut produce are discoloration, softening, off-odor development, and microbial growth. Packaging of fresh-cut produce has been changed to reduce these quality problems. Flexible packaging film is widely used to pack fresh-cut produce. Vacuum packaging was the popular packaging method in the beginning of fresh-cut industry in Korea. Vacuum packaging creates high $CO_2$ and low $O_2$ levels to control browning of fresh-cut produce. However, these conditions induce some visual defects and off-odor development. Discoloration problem was also found when fresh-cut produce was packaged with conventional packaging film or plastic tray. Modified atmosphere (MA) packaging is effective for prolonging shelf-life of fresh-cut produce by decreasing $O_2$ and increasing $CO_2$ concentration in the package. Retail MA packaging using different oxygen transmission rate (OTR) film and micro-perforated film has started to be applied to fresh-cut produce in Korea. Proper MA package design that provides optimum range of $O_2$ and $CO_2$ partial pressures is one of the major challenges in the industry. An initial package flushing with $N_2$ or an low $O_2$/high $CO_2$ atmosphere is also used to more rapidly establish steady-state MA condition. Film OTR and $O_2$ flushing affects the fermentative volatile production, off-odor development, electrolyte leakage, discoloration, $CO_2$ injury, microbial population of fresh-cut produce. There is also a demand for convenient packaging to attract consumers. Rigid fresh-cut produce container for retail market has increased since the packaging provides excellent protection from physical damage during transport. Rigid tray used as actual serving vessel for the consumer is increasing in Korea. The tray with flexible lid to wrap or seal fresh-cut produce is more and more gaining popularity. Further practical technology to control quality change and microbial growth for each fresh-cut product has been studied since various fresh-cut items were required. The fresh-cut industry also focuses on searching for more convenient and environmentally friendly packaging.

Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods (인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석)

  • Cho, C.H.;Cho, Y.K.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

Clinical considerations of impression making for edentulous patients (성공적인 총의치 제작을 위한 단계별 포인트 - 무치악인상채득, 이것이 핵심이다.)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • Regardless of the type of impression being made, the tray is the most important part of the impression-making procedure for completely edentulous patients. Dentists have to make use of a combination of rigid, thermoplastic, and resilient materials and control step-by-step procedure from irreversible hydrocolloid impression to definitive cast fabrication. For successful edentulous impression, some considerable clinical tips were guided.

  • PDF

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Reconstruction of Mandibular Bone Defect Using a Titanium Mesh with Autogenous Particulate Cortical Bone Graft by an Intraoral Approach: A Case Report (구강내 접근으로 자가 분쇄 피질골과 Titanium Mesh를 이용한 광범위한 하악골 골결손부 재건: 증례보고)

  • Choi, Seok-Tai;Leem, Dae-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.466-472
    • /
    • 2012
  • The loss of mandibular continuity due to trauma, neoplasm, or infection results in major esthetic and biologic compromise. The reconstruction of the mandibular bone defect still poses a challenge to oral and maxillofacial surgeons. There have been a number of variety graft materials. Among them, free block bone graft with rigid fixation has been widely used. However, cases using free block bone grafts may lead to a marked invasion of the donor site, mal-union, and absorption of the block bone. In this respect, particulate cortical bone using a titanium mesh tray can be an effective alternative option in order to achieve a proper bone contour and good oral rehabilitation. We have developed an intraoral approach for the mandibular reconstruction method using a titanium mesh tray with autogenous particulate cortical bone graft.

Analysis and Design of 3-DOF Parallel Mechanism Based on Kinematic Couplings (기구학적 커플링으로 구성된 3자유도 병렬 메커니즘 해석 및 설계)

  • Wang, Wei-Jun;Han, Chang-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.479-486
    • /
    • 2012
  • This paper presents a high-speed automatic micro-alignment system that is a part of an inspection machine for small-sized molded lenses of mobile phones, palm-top computers, and so on. This work was motivated by the shortcomings of existing highest-grade commercial machine. A simple tip/tilt/Z parallel mechanism is designed based on kinematic couplings, which is a 3-degree-of-freedom (3-DOF) moderate-cost alignment stage. It is used to automatically adjust the posture of each lens on the tray, which is impossible by the conventional instrument. Amplified piezoelectric actuators are used to ensure the accuracy and dynamic response. Forward kinematic analysis and simulation show that the parasitic motion is small enough compared to the actuator stroke. From the workspace analysis of the moving platform, it is clear that the output motion range satisfies the design requirements.