Rotating Reverse Osmosis Membrane Filtration (회전 역삼투 분리막 여과)

  • Sangho Lee;Richard M. Lueptow
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.131-142
    • /
    • 2003
  • Cylindrical rotating reverse osmosis (RO) is a means of dynamic filtration that incorporates both high shear and flow instabilities to reduce membrane fouling. This article summarizes recent works on rotating RO including the physics of rotating filtration; mass - transfer and concentration polarization; theoretical and experimental analysis; and some case studies.

Study of Surface Properties on Fouling Resistance of Reverse Osmosis Membranes (역삼투 분리막 표면 특성의 내오염성 상관 관계 연구)

  • 김노원
    • Membrane Journal
    • /
    • v.12 no.1
    • /
    • pp.28-40
    • /
    • 2002
  • The primary objective of this study is to elucidate the contribution of the electrostatic and molecula structural properties of an active layer of the thin film compsite (TFC) membranes to fouling tendency. The studies of surface morphology and surface charge were very effective in understanding fouling behaviors of the reverse osmosis (RO) membranes which were the thin film composite type of ployamide. Results of microscopic morphology analyzed by atomic force microscopy (AFM) and surface charge analyzed by electrokinetic analyzer (EKA) showed important factors affecting the fouling of RO membranes. The active layer of the composite membrane possessing realtively neutral streaming charge and less roughness provided a RO membrane with slowly decreasing flux.

Design of optimal PID controller for the reverse osmosis using teacher-learner-based-optimization

  • Rathore, Natwar S.;Singh, V.P.
    • Membrane and Water Treatment
    • /
    • v.9 no.2
    • /
    • pp.129-136
    • /
    • 2018
  • In this contribution, the control of multivariable reverse osmosis (RO) desalination plant using proportional-integral-derivative (PID) controllers is presented. First, feed-forward compensators are designed using simplified decoupling method and then the PID controllers are tuned for flux (flow-rate) and conductivity (salinity). The tuning of PID controllers is accomplished by minimization of the integral of squared error (ISE). The ISEs are minimized using a recently proposed algorithm named as teacher-learner-based-optimization (TLBO). TLBO algorithm is used due to being simple and being free from algorithm-specific parameters. A comparative analysis is carried out to prove the supremacy of TLBO algorithm over other state-of-art algorithms like particle swarm optimization (PSO), artificial bee colony (ABC) and differential evolution (DE). The simulation results and comparisons show that the purposed method performs better in terms of performance and can successfully be applied for tuning of PID controllers for RO desalination plants.

COD removal from industrial wastewater plants using reverse osmosis membrane

  • Madaeni, S.S.;Samieirad, S.
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.273-282
    • /
    • 2010
  • Treatment and reuse of industrial wastewater is becoming a major goal due to water scarcity. This may be carried out using membrane separation technology in general and reverse osmosis (RO) in particular. In the current study, polyamide (FT-30) membrane was employed for treatment of wastewater obtained from Faraman industrial zone based in Kermanshah (Iran). The effects of operating conditions such as transmembrane pressure, cross flow velocity, temperature and time on water flux and rejection of impurities including COD by the membrane were elucidated. The aim was an improvement in membrane performance. The results indicate that most of the chemical substances are removed from the wastewater. In particular COD removal was increased from 64 to around 100% as temperature increased from 15 to $45^{\circ}C$. The complete COD removal was obtained at transmembrane pressure of 20 bars and cross flow velocity of 1.5 m/s. The treated wastewater may be reused for various applications including makeup water for cooling towers.

Reverse Osmosis and Nanofiltration Using the Disc-tube-module in the Purification of Landfill Leachate

  • Peters, Thomas A.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.27-38
    • /
    • 1995
  • Based on innovative membrane module concepts reverse osmosis and nanofiltration are going to become important instruments in environmental engineering. One example is the Disc-Tube-module and its application for the purification of landfill leachate. Currently over 45 different landfills are using this ROCHEM DT-module, in some cases combined with the high pressure reverse osmosis versions of this module, operating at up to 120 bar and 200 bar. This state of the art membrane technology and the DTF-module for nanofiltration, developed by ROCHEM on the basis of the DT-module and RO-systems for the purification of landfill leachate, make possible in hybrid processes permeate recovery rates of more than 97 % with concentration factors up to 40.

  • PDF

Ranking and comparison of draw solutes in a forward osmosis process

  • Sudeeptha, G.;Thalla, Arun Kumar
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.411-421
    • /
    • 2017
  • Forward osmosis (FO) is an emerging technology which can possibly make the desalination process more cost and energy efficient. One of the major factors impeding its growth is the lack of an appropriate draw solute. The present study deals with the identification of potential draw solutes, and rank them. The comparison was carried out among ten draw solutes on the basis of four main parameters namely; water flux, reverse salt diffusion, flux recovery and cost. Each draw solute was given three 24 hour runs; corresponding to three different concentrations; and their flux and reverse salt diffusion values were calculated. A fresh membrane was used every time except for the fourth time which was the flux recovery experiment conducted for the lowest concentration and the change of flux and reverse salt diffusion values from the initial run was noted. The organic solutes inspected were urea and tartaric acid which showed appreciable values in other parameters viz. reverse salt diffusion, flux recovery and cost although they generated a lower flux. They ranked 5th and 8th respectively. All the experimented draw solutes were ranked based on their values corresponding to each of the four main parameters chosen for comparison and Ammonium sulfate was found to be the best draw solute.

Reuse of reverse osmosis membranes for wastewater treatment (Beni Saf Water Company)

  • Khadidja Benyahia;Mouhssin Khiari;Mourad Berrabah
    • Membrane and Water Treatment
    • /
    • v.15 no.4
    • /
    • pp.153-162
    • /
    • 2024
  • The current research project focuses on the feasibility of recycling and reusing utilized osmosis membranes from the Beni Saf water seawater desalination station in the province of Ain Temouchent. The composite Reverse Osmosis (RO) membrane, which is referenced BW30-400-FR and manufactured by Dow Filmtec TM, is used for all the tests. Three solvents are tested: potassium permanganate (KMnO4), sodium hydroxide (NaOH), hydrogen peroxide (H2O2), and the mixture of NaOH with KMnO4 for the degradation of the active layer of the RO membrane. A frontal filtration of wastewater using these modified membranes was carried out. An analysis of the physicochemical properties of the filtrate was performed using a spectrophotometer. The results of the frontal filtration performed under perpendicular pressure using a filtration ramp show that the membranes immersed in the NaOH and KMnO4 mixture for 24 hours produced a higher hydraulic flux compared to those immersed in NaOH and H2O2. At the end of the proposed treatment, the samples are analyzed by scanning electron microscopy (SEM) in addition to analyzing the clogging powder by EDX. The obtained results show the effectiveness of the proposed treatment for the degradation of the active layer in order to transform it into microfiltration and/or ultrafiltration.

The Outlook for Forward Osmosis-Reverse Osmosis (FO-RO) Hybrid Desalination Market (해수담수화 시장의 전망(정삼투-역삼투 융합기술 측면에서))

  • Kim, Jakyum;Han, Jihee;Sohn, Jinsik;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.521-532
    • /
    • 2016
  • Seawater desalination market after global economic crisis has been stalled due to the market uncertainties and decreased demand in desalination. It is important to review the status of the market and to estimate the appropriate share of Forward osmosis-Reverse Osmosis (FO-RO) hybrid desalination technology by figuring out the outlook of the desalination market. Main part of the desalination market will still be MENA (Middle East and North Africa) in the near future due to the fast population increase and high dependency of fossil fuel in the region. The market for FO-RO hybrid technology, however, might be smaller than the conventional SWRO desalination market anyway because of aesthetic issues from using wastewater as raw water and higher costs associated with capex. Therefore, it is essential to improve FO membrane performance and system operation technologies in order to make the hybrid technology attractive compared to the conventional SWRO technology.

A Study on the Ethanol Concentration by Osmotic Sink Reverse Osmosis Process (Osmotic Sink Reverse Osmosis Process를 이용한 에탄올의 농축특성에 관한 연구)

  • 이광현
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.04a
    • /
    • pp.1-4
    • /
    • 1992
  • 기존의 일반적인 에탄올 제조법으로는 1) ethylene의 가수분해, 2)전분이나 당분의 발효, 3)acetylene으로부터 얻은 acetaldehyde의 환원반응이 있다. 기존의 화석연로에 의존하지 않고 에탄올을 생성하는 방법은 발효에 의한 방법이다. 발효에 의해 생성되는 에탄올의 농도는 batch식 발효에서 13-14%, 고정화 발효방법에서 5-10%정도이다. 이를 고순도의 에탄올로 농축하기 위한 방법으로는 증류법, 투과증발법, 역삼투법등이 있으며 증류를 이용하여 농축하는 경우에는 상당히 큰 열에너지를 필요로 한다.

  • PDF

Optimal Flow Rate Evaluation for Low Energy, High Efficiency Cleaning of Forward Osmosis (FO) (정삼투 공정의 저에너지 고효율 세정을 위한 최적 유속 평가)

  • Kim, Yihyang;Kim, Jungbin;Zhan, Min;Min, Dahae;Hong, Seungkwan
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.339-347
    • /
    • 2019
  • Forward osmosis (FO) is operated at a lower pressure than reverse osmosis (RO), which has great advantages in terms of fouling control, maintenance, membrane cleaning, and potential energy reduction. In particular, since the membrane fouling layer of the forward osmosis process has a relatively loose and dispersed property, it is possible to control the membrane fouling by physical cleaning, unlike the reverse osmosis process. However, existing studies do not apply the proper cleaning flow rate for forward osmosis physical cleaning, and thus there is a limit that the optimal operation can not be performed. Therefore, this study aims to evaluate the justification of proper flow rate that can show high efficiency cleaning with economical energy amount. The membrane fouling experiments of the forward osmosis process were maintained at a circulating flow rate of 8.54 cm/s and the recovery rates were compared with the three cleaning flow rates. As a result of this experiment, it was confirmed that the 2 × speed cleaning showed the same efficiency as the water permeability recovery rate of the 3 × speed cleaning, and it was confirmed that the 2 × speed cleaning was an appropriate flow rate with high cleaning efficiency and economical SEC.