• Title/Summary/Keyword: reverse operation

Search Result 386, Processing Time 0.024 seconds

Cost-Effective Modular Electroeionization (EDI)

  • Tessier, David F.;Haas, William E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.143-158
    • /
    • 1997
  • Electrochemical deionization (EDI) offers continuous demineralization at higher water recovery rates (>90%), compared with mixed bed ion exchange, and without the use of chemical regenerants and the associated production of saline waste water. Although EDI technology has been used in some power generation applications, its wider application requires the satisfactory resolution of outstanding capital cost and performance issues. This paper reports on the field evaluation of a new cost-effective EDI technology in a power generation application. The E-Cell System$^{TM}$, which became commercially available in the fourth quarter of 1996, consists of a rugged, modular system, based on a new high-performance EDI stack. Starting in May 1996, a 100 gpm modular EDI pilot system, rated for operation at 100 psi, was evaluated at the TVA Brown's Ferry Nuclear Plant. The feed consisted of Reverse Osmosis (RO) permeate with a conductivity of 4-7 $\mu$S/cm. The pilot system reliably produced 17.8-18.0 M$\Omega$.cm water under design operating conditions, independent. Silica levels were reduced from ca. 50 ppb to 4 ppb, while TOC levels were reduced from ca. 120 ppb to 30 ppb.

  • PDF

New High Recovery Membrane Modules for Desalination

  • Fujiwara, Nobuya
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.1-12
    • /
    • 2002
  • Desalination by reverse osmosis (RO), which first entered commercial use in the 1970s, was initially mainly used for treating brackish water. Technological progress led to the development of an RO membrane enabling single-pass seawater desalination. Toyobo succeeded in developing a single-pass seawater desalination RO module composed of hollow fiber type membranes made of cellulose triacetate in 1978, and then in 1979 began production of the first commercially available double-element module. This double-element module has many advantages suitable for seawater desalination. It has high chlorine tolerance and high salt rejection, derived from the properties of the membrane material, and it is highly resistant to fouling and scaling matters due to the unique flow pattern and fiber bundle configuration. These advantages help to explain why the Toyobo double-element module has been used so successfully at the many seawater desalination plants around the world. Since the 1980s, large plants capable of desalinating several tens of thousands of cubic meters a day have sprung up around the Mediterranean and In the Middle East. The Jeddah RO Phase I Plant, which has a capacity of 56, 800m$^3$/day, went into operation in 1989. In 1994, the same sized Phase II Plant came on stream, giving the plant a huge total capacity of 113, 600m$^3$/day. The plant constructor Mitsubishi Heavy Industries, Ltd. (MHI), and the RO membrane manufacturer Toyobo Co., Ltd. In 1998, the world's largest RO seawater desalination plant in operation, which has a capacity of 128, 000m$^3$/day and is run by Saudi Arabia's Saline Water Conversion Corporation (SWCC), went into operation at Yanbu. RO seawater desalination technology has thus already reached the stage of full-scale commercial use. In order to encourage its wider use, however, RO desalination needs to be made more economical by lowering construction and water treatment costs. Toyobo has therefore developed a new economical RO desalination system by a recovery ratio of 60% using a high-pressure module with a high product flow rate. In 2000, Toyobo high recovery membrane module was selected for the largest seawater desalination plant in Japan, which has a capacity of 50, 000m$^3$/day.

  • PDF

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF

The Enhanced Analysis Algorithm for an EMFG's Operation (EMFG의 개선된 동작해석 알고리즘)

  • Kim, Hee-Jung;Yeo, Jeong-Mo;Seo, Kyung-Ryong
    • The KIPS Transactions:PartA
    • /
    • v.9A no.3
    • /
    • pp.371-378
    • /
    • 2002
  • The EMFG (Extended Mark Flow Graph) is known as a graph model for representing the discrete event systems. In this paper, we introduce input/output matrixes representing the marking variance of input/output boxes when each transition fires in an EMFG, and compute an incidence matrix. We represent firing conditions of transitions to a firing condition matrix for computing a firable vector, and introduce the firing completion vector to decide completion of each transition’s firing. By using them, we improve an analysis algorithm of the EMFG’s operation to be represented all the process of EMFG’s operation mathematically. We apply the proposed algorithm to the system repeating the forward and reverse revolution, and then confirm that it is valid. The proposed algorithm is useful to analysis the variant discrete event systems.

The Variation of Water Quality due to Sulice Gate Operation in Shiwha Lake (시화호의 배수갑문 운용에 따른 수질변화)

  • 김종구;김준우;조은일
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1205-1215
    • /
    • 2002
  • To evaluate the change for water quality after the water gate operation in Shiwha lake, in situ survey were conducted on september in 2000 and January, march, jane in 2001. Chemical characteristics and eutrophication level was estimated from the survey data. The water quality of the Shihwa lake was greatly affected by pollutant load from rainfall, and formation of stratification in summer and winter was increased to effect on nutrient release from sediment. Especially, high concentration of chlorophyll-a was occurred in autumn, due to increased nutrient, high water temperature and low salinity after rainfall runoff. The mean concentration of DIN, DIP were 0.346mg/L, 0.0217mg/L in surface water and 0.826mg/L, 0.0415mg/L in bottom water, respectively, which were over III grade of seawater standard. Also high percentage of ammonia nitrogen to DIN in bottom water for autumn and winter was affected by released nutrient from sediment. Correlation analysis of chlorophyll-a versus TSS was shown that organic matter was affected by autochthonous organic matter stem from the algae, these factor showed reverse correlation about salinity. Closely correlations among to the water quality constituent in continuity survey was appeared. The results of eutrophication index estimation showed the high potentiality of red tide occurrence in Shiwha lake, particularity in summer or fall. Overall water quality was greatly improve to compared with measuring data during 1997~1998 at the beginning water gate operation, which reported by KORDI. Therefore, to improve of water quality in Shiwha lake, we need to establish of management plan about nutrient release from sediment, rainfall runoff, maximum of seawater exchange.

High Level Design and Performance Evaluation for the Implementation of WCDMA Base Station Modem (WCDMA 기지국 모뎀의 구현을 위한 상위 레벨 설계 및 통합 성능 평가)

  • Do Joo-Hyun;Lee Young-Yong;Chung Sung-Hyun;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1A
    • /
    • pp.10-27
    • /
    • 2005
  • In this paper, we propose a high level design architecture of WCDMA(UMTS) base station modem and synchronization algorithms applied to the proposed architecture. Also analysis of each synchronization algorithm and performance evaluation of fixed point designed modem are shown. Since the target system is base station modem, each synchronization algorithm is designed for its stable operation. To minimize implementation complexity, optimum fixed point design for best operation of synchronization algorithms is performed. We performed symbol level link simulation with fixed point designed modem simulator for data rate of 12.2kbps, 64kbps, 144kbps, and 384kbps. We compared performance results to the minimum requirements specified in 3GPP TS 25.104(Release 5). Extensive computer simulation shows that the proposed modem architecture has stable operation and outperform the minimum requirement by 2 dB. The proposed modem architecture has been applied in the implementation of WCDMA reverse link receiver modem chip successfully.

Comparative Analysis of Game-Theoretic Demand Allocation for Enhancing Profitability of Whole Supply Chain (전체 공급망 수익성 개선을 위한 게임이론 기반의 수요 할당 메커니즘의 비교 연구)

  • Shin, Kwang Sup
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.1
    • /
    • pp.43-61
    • /
    • 2014
  • This research is an application of game theory to developing the supplier selection and demand allocation mechanism, which are the essential and major research areas of supply chain planning and operation. In this research, the most popular and widely accepted mechanism, the progressive reverse auction is analyzed and compared with the other game theoretic approach, Kalai-Smorodinsky Bargaining Solution in the viewpoint of holistic efficiency of supply chain operation. To logically and exquisitely compare the efficiencies, a heuristic algorithm based on Genetic Algorithm is devised to find the other optimal demand allocation plan. A well known metric, profit-cost ratio, as well as profit functions for both suppliers and buyer has been designed for evaluating the overall profitability of supply chain. The experimental results with synthesis data and supply chain model which were made to mimic practical supply chain are illustrated and analyzed to show how the proposed approach can enhance the profitability of supply chain planning. Based on the result, it can be said that the proposed mechanism using bargainging solution mayguarantee the better profitability for the whole supply chin including both suppliers and buyer, even though quite small portion of buyer's profitability should be sacrified.

A Study on Power Trading Methods for in a Hydrogen Residential Model (수소주거모델의 전력 거래 참여 방안 고찰)

  • KISEOK JEONG;TAEYOUNG JYUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.

Development of HST electronic control system for combine (II)- Outdoor tests for control Characteristics - (콤바인 HST 전자제어시스템 개발- 제어특성 실외시험 -)

  • Seo, Sin-Won;Huh, Yun-Kun;Lee, Je-Yong;Lee, Chang-Kyu;Bae, Keun-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.121-128
    • /
    • 2011
  • I/An electro-hydraulic transmission having advantages of convenience, safety, simple linking and high power, and an electronic control system were designed and fabricated. In this study, characteristics of the control system were investigated through outdoor tests for evaluation of installation of the system on a combine. Major findings were as followings. 1. Experiment for performance evaluation of the control system was conducted on concrete road. With steering lever in neutral position, driving HST swash plate and left/right wheel speed increased in proportion to driving lever angle. In case of steering control, steering swash plate angle changed in proportion to steering lever angle. This should cause increase in outer wheel speed, but it was observed that HST swash plate was controlled toward neutral to maintain the speed before steering. As a result, speed before steering was maintained despite the change in outer wheel speed by steering HST swash plate angle change. 2. It was observed that the HST system enabled steering with outer wheel maintained at constant speeds while inner wheel speed decreased, which was more stable than conventional mechanical links. In addition, for the selected 5 criteria, experiment showed satisfactory results and it was judged that installation on real vehicle would be feasible. 3. The control system showed response property of appropriate forward/reverse movement and lift/right steering, without causing any problems during experiment on concrete. Result of response property experiment on field operation also showed appropriate control over forward/reverse movement and left/right steering.

Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition (착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.573-577
    • /
    • 2013
  • Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.