Abstract
Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.
Keywords
Heat Pump; Continuous Heating; COP; Frost; Defrosting;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. Nutter and L. O'Neal, "Shortening the defrost cycle time with active enhancement within the suction-line accumulator of an air-source heat pump", International Mechanical Engineering Congress and Exposition, Vol. 36, pp. 59-68, 1996.
2 C. D. Jeon, "Heat Exchanger", Korean Intellectual Property Office, 10-2009-0079191.
3 C. D. Jeon, "Heat Pump", Korean Intellectual Property Office, 10-2010-0070410.
4 KS C 9306, Air Conditioner, 2002.
5 Y. Xia, Y. Zhong, S. Hrnjak, M. Jacobi, "Frost, defrost, and refrost and its impact on the air-side thermal-hydraulic performance of louvered-fin, flat-fin tube heat exchanger", Int. J. Refrigeration, Vol. 29, pp. 1066-1079, 2006. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2006.03.005   DOI   ScienceOn