• Title/Summary/Keyword: restorative

Search Result 2,651, Processing Time 0.025 seconds

COMPARISON OF ANTIBACTERIAL EFFECT OF Listerine(R) WITH VARIOUS ROOT CANAL IRRIGANTS (수종의 근관세척액과 Listerine(R)의 항균성 비교 연구)

  • Kim, Young-Hun;Kang, Min-Kyung;Choi, Eun-Kyoung;Yang, So-Young;Yang, In-Seok;Kang, In-Chol;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.500-507
    • /
    • 2009
  • The purpose of this study is to compare the antibacterial effect of $Listerine^{(R)}$ on two microorganisms (P. gingivalis and E. faecalis) with various root canal irrigants (NaOCl, CHX, EDTA) and to identify possibility of using $Listerine^{(R)}$ as a root canal irrigant. Porphyromonas gingivalis ATCC 3327 and Enterococcus faecalis ATCC 29212 were used in this experiment. For the test irrigants, 0.5%, 1%, 2.5%, 5.25% NaOCl, 0.1%, 0.2%, 1%, 2% CHX, 0.5M EDTA (18.6% EDTA) and $Listerine^{(R)}$ were prepared. Distiled water was used as control. Two methods-1) Comparison of turbidity in broth and 2) Agar diffusion test-were used to determine the extent of antibacterial effect of $Listerine^{(R)}$ and to compare it with that of NaOCl, CHX, and EDTA. All solutions tested were effective against two bacterial strains compared with control (p < 0.001). Any concentration of NaOCl, CHX, and EDTA showed similarly high effectiveness against all bacterial strains. In all experiment, $Listerine^{(R)}$ showed significantly low antibacterial effect compared with the other root canal irrigants (p < 0.05). In conclusion, the results reflect remarkably low antibacterial effect of $Listerine^{(R)}$ as compared with root canal irrigants in general so it is not suitable for the root canal irrigant.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Effect of adhesive hydrophobicity on microtensile bond strength of low-shrinkage silorane resin to dentin (접착시스템의 소수성이 Low-shrinkage silorane resin과 상아질의 미세인장강도에 미치는 영향)

  • Cho, So-Yeun;Kang, Hyun-Young;Kim, Kyoung-A;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.280-289
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate ${\mu}TBS$ (microtensile bond strength) of current dentin bonding adhesives which have different hydrophobicity with low-shrinkage silorane resin. Materials and Methods: Thirty-six human third molars were used. Middle dentin was exposed. The teeth were randomly assigned to nine experimental groups: Silorane self-etch adhesives (SS), SS + phosphoric acid etching (SS + pa), Adper easy bond (AE), AE + Silorane system bonding (AE + SSb), Clearfil SE bond (CSE), CSE + SSb, All-Bond 2 (AB2), AB2 + SSb, All-Bond 3 (AB3). After adhesive's were applied, the clinical crowns were restored with Filtek LS (3M ESPE). The 0.8 mm ${\times}$ 0.8 mm sticks were submitted to a tensile load using a Micro Tensile Tester (Bisco Inc.). Water sorption was measured to estimate hydrophobicity adhesives. Results: ${\mu}TBS$ of silorane resin to 5 adhesives: SS, 23.2 MPa; CSE, 19.4 MPa; AB3, 30.3 MPa; AB2 and AE, no bond. Additional layering of SSb: CSE + SSb, 26.2 MPa; AB2 + SSb, 33.9 MPa; AE + SSb, no bond. High value of ${\mu}TBS$ was related to cohesive failure. SS showed the lowest water sorption. AE showed the highest solubility. Conclusions: The hydrophobicity of adhesive increased, and silorane resin bond-strength was also increased. Additional hydrophobic adhesive layer did not increase the bond-strength to silorane resin except AB2 + SSb. All-Bond 3 showed similar ${\mu}TBS$ & water sorption with SS. By these facts, we could reach a conclusion that All-Bond 3 is a competitive adhesive which can replace the Silorane adhesive system.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.

Clinical assessment of whitening efficacy and safety of in-office tooth whitening system containing 15% hydrogen peroxide with or without light activation (15% 과산화수소 함유 전문가용 치아 미백제의 광활성화 여부에 따른 미백효과 및 안전성에 관한 임상평가)

  • Noh, Young-Suk;Rho, Young-Jee;Yoo, Yeon-Jee;Lee, Hyang-Ok;Lim, Sang-Min;Kweon, Hyun-Jeong;Kim, Ye-Un;Park, Seong-Yeon;Yoon, Hee-Young;Lee, Jung-Hyun;Lee, Chan-Hee;Oh, So-Ram;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2011
  • Objectives: This clinical study evaluated the effect of light activation on the whitening efficacy and safety of in-office bleaching system containing 15% hydrogen peroxide gel. Materials and Methods: Thirty-three volunteers were randomly treated with (n = 17, experimental group) or without light activation (n = 16, control group), using Zoom2 white gel (15% $H_2O_2$, Discus Dental) for a total treatment time of 45 min. Visual and instrumental color measurements were obtained using Vitapan Classical shade guide and Shadepilot (DeguDent) at screening test, after bleaching, and 1 month and 3 month after bleaching. Data were analyzed using t-test, repeated measure ANOVA, and chi-squared test. Results: Zoom2 white gel produced significant shade changes in both experimental and control group when pre-treatment shade was compared with that after bleaching. However, shade difference between two groups was not statistically significant (p > 0.05). Tooth shade relapse was not detected at 3 months after bleaching. The incidence of transient tooth sensitivity was 39.4%, with being no differences between two groups. Conclusions: The application of light activation with Zoom2 white gel system neither achieved additional whitening effects nor showed more detrimental influences.

Elemental analysis of the fluoride varnish effects on root caries initiation (불소 바니쉬 도포 후 초기 치근 우식 발현에 대한 정량원소분석)

  • Park, Se-Eun;Yi, Kee-Wook;Kim, Hae-Young;Son, Ho-Hyun;Chang, Ju-Hea
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.290-299
    • /
    • 2011
  • Objectives: The usage of fluoride varnish for a moderate to low caries-risk group has not been well validated. This study aimed to evaluate the preventive and therapeutic efficacies of fluoride varnish on the initiated root caries. Materials and Methods: Ten premolars were sectioned into quarters, further divided into two windows, one of which was painted with Fluor Protector (1,000 ppm fluoride, Ivoclar Vivadent). An initial lesion with a well-preserved surface layer was produced by pH cycling. Scanned line analysis using energy dispersive spectrometry determined the weight percentages of Ca and P in the demineralized layer. Scanning Electron microscopy and confocal laser scanning microscopy (CLSM) evaluated the varnish-applied root surfaces. Results: The mean lesion depth (SD) was 12.3 (2.6) ${\mu}m$ (single cycling) and 19.6 (3.8) ${\mu}m$ (double cycling). Double cycling extended the lesion depth, but induced no more mineral loss than single cycling (p < 0.05). The mean weight percentages of Ca and P between groups with and without varnish were not significantly different (p < 0.05). A CLSM showed varnish remained within 15 ${\mu}m$ of the surface layer. Conclusions: When a mild acid challenge initiated root tissue demineralization, the application of low-concentration fluoride varnish did not influence the lesion depth or the mineral composition of the subsurface lesion.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.

THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS (열순환이 상아질 접착제의 결합 내구성에 미치는 영향)

  • Moon, Young-Hoon;Kim, Jong-Ryul;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.222-235
    • /
    • 2007
  • The objectives of this study was to evaluate the effect of thermocycling on the ${\mu}TBS$ (microtensile bond strength) to dentin with four different adhesive systems to examine the bonding durability. Freshly extracted $3^{rd}$ molar teeth were exposed occlusal dentin surfaces, and randomly distributed into 8 adhesive groups 3-steps total-etching (Scotchbond Multi-Purpose Plus; SM, All Bond-2; AB), 2-steps total-etching (Single Bond; SB, One Step plus; OS), 2-steps self-etching (Clearfil SE Bond; SE, AdheSE AD) and single-step self-etching systems (Promp L-Pop; PL, Xeno III; XE) Each adhesive system in 8 adhesives groups was applied on prepared dentin surface as an instruction and resin composite (Z250) was placed incrementally and light-cured. The bonded specimens were sectioned with low-speed diamond saw to obtain $1\times1mm$ sticks after 24 hours of storage at $37^{\circ}C$ distilled water and proceeded thermocycling at the pre-determined cycles of 0, 1,000 and 2,000. The ${\mu}TBS$ test was carried out with EZ-tester at 1mm/min. The results of bond strength test were statistically analyzed using one-way ANOVA/ Duncan's test at the a < 0.05 confidence level. Also, the fracture mode of debonded surface and the interface were examined under SEM. The results of this study were as follows ; 1. 3-step total etching adhesives showed stable, but bond strength of 2-step adhesives were decreased as thermocycling stress. 2. SE showed the highest bond strength, but single step adhesives (PL, XE) had the lowest value both before and after thermocycling. 3 Most of adhesives showed adhesive failure. The total-etching systems were prone to adhesive failure and the single-step systems were mixed failure after thermocycling. Within limited results of this study, the bond strength of adhesive system was material specific and the bonding durability was affected by the bonding step/ procedure of adhesive Simplified bonding procedures do not necessarily imply improved bonding performance.