• Title/Summary/Keyword: response sensitivity

Search Result 1,785, Processing Time 0.044 seconds

Isolation and characterization of sigH from Corynebacterium glutamicum (Corynebacterium glutamicum의 sigH 유전자의 분리 및 기능분석)

  • Kim Tae-Hyun;Kim Hyung-Joon;Park Joon-Sung;Kim Younhee;Lee Heung-Shick
    • Korean Journal of Microbiology
    • /
    • v.41 no.2
    • /
    • pp.99-104
    • /
    • 2005
  • Corynebacterial clones which exert regulatory effects on the expression of the glyoxylate bypass genes were isolated using a reporter plasmid carrying the enteric lacZ fused to the aceB promoter of Corynebacterium glutamicum. Some clones carried common fragments as turned out by DNA mapping technique. Subcloning analysis followed by the measurement of $\beta-galactosidase$ activity in Escherichia coli identified the region responsible for the aceB-repressing activity. Sequence analysis of the DNA fragment identified two independent ORFs of ORF1 and ORF2. Among them, ORF2 was turned out to be responsible for the aceB-repressing activity. ORF1 encoded a 23,216 Da protein composed of 206 amino acids. Sequence similarity search indicated that the ORF may encode a ECF-type $\sigma$ factor and designated sigH. To identify the function of sigH, C. glutamicum sigH mutant was constructed by gene disruption technique and the sigH mutant showed growth retardation as compared to the wild type strain. In addition, the mutant strain showed sensitivity to oxidative-stress generating agent plumbagin. This result imply that sigH is probably involved in the stress response occurring during normal cell growth.

The Role of Plasma B-type Natriuretic Peptide Measurements in the Differential Diagnosis of Acute Dyspnea (급성호흡곤란의 감별진단에서 혈장 B-type Natriuretic Peptide의 역할)

  • Moon, Ji Yong;Bae, Joong Ho;Kim, Tae Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.656-663
    • /
    • 2005
  • Background : The B-type natriuretic peptide (BNP) is a cardiac neurohormone that is specifically secreted from the ventricles in response to volume expansion and a pressure overload. Differentiating congestive heart failure from the pulmonary causes of dyspnea is very important for patients presenting with acute dyspnea. Methods : A retrospective study was carried out on 261 patients who were admitted to the emergency department of Hanyang University Hospital due to acute dyspnea from March to July 2004. The serum BNP levels of the patients were measured using the ELISA method. Results : The BNP levels were 382, 111-1140 pg/ml (median, interquartile range) in the heart failure group (n=119) and 29, 7-81 pg/ml in the non-heart failure group (n=142). The BNP levels according to the subgroups of heart failure were 820, 354-1620 pg/ml, 1650, 239-1990 pg/ml, and 378, 106-1120 pg/ml for the chronic obstructive pulmonary disease (COPD) with combined left heart failure (n=5), cor pulmonale (n=3), and left heart failure groups (n=111), respectively. The BNP levels according to the subgroups of non-heart failure were 39, 21-101 pg/ml, 59, 10-129 pg/ml, and 15, 6-47 pg/ml for the COPD (n=20), other pulmonary diseases (n=56), and other causes groups (n=66), respectively. The BNP levels were significantly different according to the underlying etiology (p<0.001), and were significantly higher in the COPD patients with left heart failure than in those without (p=0.002). When the patients with no cardiovascular risk factor such as diabetes mellitus, hypertension, smoking or renal failure were analyzed, the BNP levels were also significantly higher in the patients with heart failure than in those without(p<0.001). When 133 pg/ml was designated as the BNP cut-off level the sensitivity for predicting heart failure was 73 percent and the specificity was 87 percent. Conclusion : BNP measurements are useful for determining the presence of heart failure in the patients presenting with acute dyspnea. The possibility of heart failure must be seriously considered in patients with high BNP levels even when they have a pre-existing pulmonary disease such as COPD or no risk factors for heart failure.

The Application of B-Type Natriuretic Peptide Level of the Dyspneic Patients : Differentiation Between Cor Pulmonale and Left Ventricular Dysfunction (호흡곤란을 주소로 내원한 환자에서 혈청 B-type Natriuretic Peptide 검사의 유용성 : 폐성심과 좌심부전의 감별에 대하여)

  • Park, Hong-Hoon;Kim, Sehyun;Choi, Jeongeun;Kim, Kang-Ho;Cheon, Seok-Cheol;Lee, Jihyun;Lee, Yong-Gu;Kim, In-Jae;Cha, Dong-Hoon;Hong, Sang-Bum;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.320-329
    • /
    • 2003
  • Background : The serum B-type natriuretic peptide (BNP) is released from the ventricles as a response to volume or pressure overload of the ventricles. A few studies have reported that the BNP measurements are useful in differentiating between heart failure and pulmonary causes in patients who visited the emergency department with dyspnea as the chief complaint. It is difficult to differentiate a right heart failure from a left heart failure in the emergency room. However, there is no report on the application of a BNP assay to differentiate in right heart failure from left heart failure. In this study, the BNP levels were measured from dyspneic patients in the emergency department to determine whether or not the BNP level would be useful in differentiating the cause of the dyspnea from right ventricular failure and left ventricular failure. Method : 89 patients who visited emergency department of the Bundang Cha Hospital with dyspnea from June 2002 to March 2003 were selected. The 29 patients from the outpatient clinics and inpatients were randomly selected as the control. Results : The BNP levels of patients in the left heart failure group were significantly different from that of the patients in the right heart failure group ($682{\pm}314$ pg/mL vs. $149{\pm}94$ pg/mL, p=0.000). When the BNP cut-off level was designated as 219 pg/mL using the receiver operating characteristic curve, the sensitivity was 94.3%, and specificity was 92.9%. In addition, the positive predictive value was 97% and the negative predictive value was 86.7% in differentiating right heart failure from left heart failure. Conclusion : Measurements of the serum BNP levels is an accurate and rapid method that can aid in distinguishing between right heart failure and left heart failure.

Soluble Triggering Receptor Expressed on Myeloid cells-1: Role in the Diagnosis of Pleural Effusions (흉수의 감별 진단 시 Soluble Triggering Receptor Expressed on Myeloid Cells-1 (sTREM-1)의 유용성)

  • Kim, Jung-Hyun;Park, Eun-Young;Kim, Won-Hee;Park, Woong;Jeong, Hye-Cheol;Lee, Ji-Hyun;Kim, Eun-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.290-298
    • /
    • 2007
  • Background: The currently available diagnostic markers for pleural effusion have a limited role. The soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) is a molecule recently reported to play an important role in the myeloid cell mediated inflammatory response, and is up regulated in the body fluid by bacterial or fungal products. This study examined the expression of sTREM-1 in pleural effusion. Methods: Between April 2004 and December 2005, 48 patients with pleural effusions were enrolled in this study. The pleural fluids were taken and analyzed for the total protein, glucose, lactate dehydrogenase (LDH), adenosine deaminase (ADA), and sTREM-1. Bacterial cultures and cytology tests were also performed. Results: The clinical diagnoses were 17 parapneumonic, 14 tuberculous, and 13 malignant effusions. Four patients presented with transudates. The mean ages of the parapneumonic, tuberculous and malignant effusion groups were $57.1{\pm}19.7$, $49.5{\pm}18.6$, $66.9{\pm}15.5$, and $76.0{\pm}18.1$. respectively. The level of sTREM-1 expression was significantly higher in the parapneumonic effusions ($344.0{\pm}488.7$) than in the tuberculous effusions ($81.7{\pm}56.6$) and malignant effusions ($39.3{\pm}19.6$). With a cut-off value of 55.4pg/ml, the sensitivity and specificity for a parapneumonic effusion was 70.6% and 74.1%. Conclusion: sTREM-1 expression is significantly higher in parapneumonic effusions, suggesting its potential role as an additional diagnostic marker for pleural effusions.

Development of New Functional Dairy Products Containing Probiotics for Improving Human Health: A Review (Probiotics를 이용한 새로운 건강 증진 기능성 유제품 개발에 관한 연구: 총설)

  • Kim, Dong-Hyeon;Chon, Jung-Whan;Kim, Hyun-Sook;Kim, Hong-Seok;Song, Kwang-Young;Kim, Soo-Ki;Jeong, Dong-Gwan;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.35-46
    • /
    • 2015
  • Recently, much attention has been paid to the development of a value-added food category containing probiotics so as to improve human health and prevent diseases. Among various foods, the health benefits of milk and dairy products are known to humanity, and could be attributed to the bioactive components present in milk. In fermented milk products, the health benefits could be due to suitable modulation activities produced by the action of probiotic bacteria. Besides the modification of various milk components, probiotics might also act directly as preventive and therapeutic agents against some severe diseases. Probiotics promote health via their positive effects on the immune response, stimulation of natural immunity, and modulation of the production of antimicrobial peptides, cytokines, and so on. Whey proteins, a byproduct of cheese production could also have anticarcinogenic, immunostimulatory, antimicrobial, and health-promoting activities such as improving insulin sensitivity and reducing fat deposition. Therefore, milk and dairy products containing probiotics could provide various opportunities in the field of functional foods. Additionally, these functional foods may be important in the human diet and may help improve human health and prevent diseases.

  • PDF

Estimation of Groundwater Table using Ground Penetration Radar (GPR) in a Sand Tank Model and at an Alluvial Field Site (실내 모형과 현장 충적층에서 지하투과레이더를 이용한 지하수면 추정)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Choi, Doo-Houng;Koh, Yong-Kwon
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.201-216
    • /
    • 2013
  • Ground penetrating radar (GPR) surveys were conducted in a sand tank model in a laboratory and at an alluvial field site to detect the groundwater table and to investigate the influence of saturation on GPR response in the unsaturated zone. In the sand tank model, the groundwater table and saturation in the sand layer were altered by injecting water, which was then drained by a valve inserted into the bottom of the tank. GPR vertical reflection profile (VRP) data were obtained in the sand tank model for rising and lowering of the groundwater table to estimate the groundwater table and saturation. Results of the lab-scale model provide information on the sensitivity of GPR signals to changes in the water content and in the groundwater table. GPR wave velocities in the vadose zone are controlled mainly by variations in water content (increased travel time is interpreted as an increase in saturation). At the field site, VRP data were collected to a depth of 220 m to estimate the groundwater table at an alluvial site near the Nakdong river at Iryong-ri, Haman-gun, South Korea. Results of the field survey indicate that under saturated conditions, the first reflector of the GPR is indicative of the capillary fringe and not the actual groundwater table. To measure the groundwater table more accurately, we performed a GPR survey using the common mid-point (CMP) method in the vicinity of well-3, and sunk a well to check the groundwater table. The resultant CMP data revealed reflective events from the capillary fringe and groundwater table showing hyperbolic patterns. The normal moveout correction was applied to evaluate the velocity of the GPR, which improved the accuracy of saturation and groundwater table information at depth. The GPR results show that the saturation information, including the groundwater table, is useful in assessing the hydrogeologic properties of the vadose zone in the field.

Application of the Enzyme-linked Immunosorbent Assay to the Serodiagnosis of Typhoid Fever (장티푸스의 혈청학적 진단에 효소결합면역측정법(Enzyme-linked Immunosorbent Assay)의 적용 실험)

  • Kye, Ki-Shik;Kim, Yae-Hum;Choi, Kang-Won;Hwang, Eung-Soo;Kook, Yoon-Ho;Lee, Seung-Hoon;Cha, Chang-Yong
    • The Journal of the Korean Society for Microbiology
    • /
    • v.18 no.1
    • /
    • pp.73-85
    • /
    • 1983
  • The advantages of the enzyme-linked immunosorbent assay(ELISA) are its sensitivity and its simplicity in detecting IgM and IgG antibodies. For applying the ELISA to the diagnosis of typhoid fever, first of all, experiments were performed to determine which concentration of killed whole cell antigens and lipopolysaccharide(LPS) antigens of S. typhi(0.901 w) were optimally coated to the wells of the polystyrene and polyvinylchloride microplate, using the hyperimmune sera from rabbits against S. typhi. By using both kinds of antigens of S. typhi adsorbed to the ELISA microplate, the changing patterns of IgG and IgM antibodies in the sera from rabbits responding to the killed whole cell antigens of S. typhi(0901 w) during the prolonged immunization were serially traced by the ELISA. At the same time, the level of antibodies against S. typhi in sera fron patients with typhoid fever and from normal healthy persons were measured by the ELISA employing the killed whole cell antigens and LPS antigens as the coating antigens. The results obtained were summerized as follow: 1. The optimal concentration of the killed whole cell antigens, which were more easily adsorbed to the polystyrene plate than the polyvinylchloride plate, was $10^8cells/ml$ of carbonate buffer(pH. 9.6) on the wells of the polystyrene plate when treated at $37^{\circ}C$ for 4 hours. On the other hand, the optimal concentration of lipopolysaccharide antigens, which were adsorbed only to the polyvinylchloride plate, was $100{\mu}g/ml$ of carbonate buffer(pH. 9.6) on the wells of the polyvinylchloride plate when treated at $37^{\circ}C$ for 4 hours. 2. IgM antibody response were dominating in rabbits responding to the killed whole cell antigens of S. typhi(0.901 w), and were more specific to the LPS antigens than to the killed whole cell antigens in the ELISA. Good correlations were made between the IgM titers by the ELISA and the aggglutinating titers of sera from the immunized rabbits. 3. Both IgG and IgM agglutination titers by the ELISA in sera from most of patients with typhoid fever were above 1:320 but those in sera from most of normal, healthy persons were below 1:80. 4. There were close correlations between the antibody titers by the ELISA and the agglutinating titers to the killed whole cell antigens in the tested human sera, IgM titers being more correlated with the agglutinating titers than IgG titers. But a little correlations were made between the antibody titers by the ELISA and the agglutinating titers to the LPS antigens. 5. IgM titers in the tested human sera were similar to IgG titers detected by the ELISA employing the killd whole cells antigens and the LPS antigens. 6. Good correlations were made between the antibody titers demonstrated by the ELISA performed on the killed whole cell antigens and the LPS antigens as the different, coating antigens on the ELISA microplates.

  • PDF

Evaluation of a Serodiagnostic Method for Tuberculosis by Using Secreted Protein Antigens of Mycobacterium Tuberculosis (결핵균 분비항원을 이용한 결핵의 혈청학적 진단 방법에 대한 평가)

  • Bai, Gill-Han;Park, Eun-Mi;Kim, Sang-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.315-323
    • /
    • 2000
  • Background : An immunochromatographic assay (ICT Diagnostics) which facilitates the diagnosis of tuberculosis(TB) by detecting serum antibodies mainly directed against specific 38KDa of Mycobacterium tuberculosis has come into the market. The test consists of a cardboard folding device containing nitrocellulose strip and absorbent pads. The whole procedure is completed within 15 min and does not require any additional equipment. The test has been reported to be sensitive and specific in diagnosing active TB. Thus the test had been evaluated with sera from TB patients and TB-free subjects. Method : Sera from patients with active pulmonary tuberculosis(40 sputum positives for Mycobacterium tuberculosis, 79 sputum negatives, and 3 extrapulmonary tuberculosis) were obtained from the Double-Cross Chest Clinic of the Korean National Tuberculosis Association (KNTA) in Seoul. The control group consisted of TB-free 68 subjects(21 children under 7 years old and 47 healthy staff members of KNTA). Results : Nine out of 68(13.2%) TB-free controls had positive antibody response. Total 106 of 122(86.9%) radiologically active patients had positive antibodies while 16 (13.1%) showed negative reaction. Antibody was detected in 38 of 40(95.0%) sputum positive patients and 68 of 82(82.9%) sputum negative patients who were under the antituberculosis chemotherapy. The sensitivity and specificity were all 87% and the positive predictive value was 92.2% while the negative predictive value was 78.7%, when the prevalence of TB in the sample was 64.2%. Our results clearly show that the detection of antibodies which mainly react with the 38KDa antigen of M. tuberculosis is not suitable as the first-line method of diagnosis but considered only as an adjunctive test to standard techniques of tuberculosis diagnosis. when considering its high false positivity.

  • PDF

Prognostic Utility of the Soluble Triggering Receptor Expressed on Myeloid Cells-1 in Patients with Acute Respiratory Distress Syndrome (급성호흡곤란증후군 환자에서 Soluble Triggering Receptor Expressed on Myeloid Cells-1의 예후인자로서의 유용성)

  • Huh, Jin Won;Jung, Hoon;Lim, Chae-Man;Koh, Younsuck;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.4
    • /
    • pp.301-307
    • /
    • 2008
  • Background: The triggering receptor expressed on myeloid cells-1 (TREM-1) is an activating receptor that is expressed on the surface of neutrophils and mature monocytes when stimulated with several microbial components, which can amplify the inflammatory response. This study analyzed the prognostic value of the sTREM-1 levels in patients with acute respiratory distress syndrome (ARDS). Methods: The bronchoalveolar lavage (BAL) fluid and blood was collected prospectively from 32 patients with ARDS, 15 survivors and 17 nonsurvivors. An enzyme-linked immunosorbent assay was performed to measure the sTREM-1. The following data was obtained: APACHE II score, Clinical Pulmonary Infection Score (CPIS), BAL fluid analysis, C-reative protein. Mortality in the ICU was defined as the end point. Results: The serum sTREM-1 level was significantly higher in the nonsurvivors than survivors ($54.3{\pm}10.3pg/ml$ vs. $22.7{\pm}2.3pg/ml$, p<0.05). The sTREM-1 level in the serum, but not in the BAL fluid, was an independent predictor of the ICU mortality (OR: 22.051, 95% CI: 1.780~273.148, p<0.016), and a cut-off value of ${\geq}33pg/ml$ yielded a diagnostic sensitivity of 71% and specificity of 93%. Conclusion: The serum sTREM-1 level may be a useful predictor of the outcome of ARDS patients.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.