• Title/Summary/Keyword: resonant

Search Result 4,132, Processing Time 0.038 seconds

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

Non-invasive Measurements of the Thickness of YBCO Thin Films by Using Microwave Resonators: Roles of the Uncertainty in the Calibration Film Thickness (마이크로파 공진기를 이용한 YBCO 박막 두께의 비파괴적 측정: 캘리브레이션 박막 두께의 불확도의 역할)

  • Kim, Myung-Su;Jung, Ho-Sang;Yang, Woo-Il;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.45-51
    • /
    • 2012
  • Microwave metrology for the thickness of metallic or superconductive films provides a new way to measure the film thickness in a non-invasive way by using microwave resonators, with the measurement accuracy affected by standard uncertainties in the resonator quality factor, temperature-dependent resonant frequency and the dimensions of the resonators. Here we study effects of the standard uncertainty in the thickness, $t_{cal}$, of a calibration $YBa_2Cu_3O_{7-{\delta}}$ (YBCO) film on the measured thicknesses, $t_{RF}$, by using a ~ 40 GHz microwave resonator. For the study, we used five YBCO films having the thicknesses of 70 - 360 nm, for which relative standard uncertainties in $t_{RF}$ due to that in $t_{cal}$ are obtained. The standard uncertainty in $t_{cal}$ was determined with the surface roughness of the film taken into account. It appeared that relative standard uncertainty in $t_{cal}$ significantly affects the $t_{RF}$ values, with the values of 1% (5%) in the former resulting in those of 1-2% (5-9%) for the latter at 10 K. Our results show that, for realizing relative standard uncertainties less than 5% in $t_{RF}$ for all the YBCO films, the surface roughness of the calibration films should be small enough to realize a relative standard uncertainty of less than 2.7% in $t_{cal}$.

Fabrication of Inductors, Capacitors and LC Hybrid Devices using Oxides Thin Films (산화물 박막을 이용한 인덕터, 캐패시터 및 LC 복합 소자 제조)

  • Kim, Min-Hong;Yeo, Hwan-Guk;Hwang, Gi-Hyeon;Lee, Dae-Hyeong;Kim, In-Tae;Yun, Ui-Jun;Kim, Hyeong-Jun;Park, Sun-Ja
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 1997
  • bliniaturization oi microwave circuit components is an important issue with the development in the mobile communication. Capacitors, inductors anti hybrid devices of these are building blocks of electric circuits, and the fabrication of these devices using thin film technology will influence on the miniaturization of electronic devices In this paper, we report the successful fabrication of the inductors, capacitors and LC hybrid devices using a ferroelectric and a ferromagnetic oxide thin iilm. Au, stable at high temperatures in oxidizing ambient, is patterned by lift-off process, and oxide thin films are deposited by ion beam sputtering and chemical vapor deposition. These devices are characterized by a network analyzer in 0.5-15GtIz range We got the inductance of 5nH, capacitance oi 10, 000 pF and resonant frequencies of $10^{6}-10^{9}Hz$.

  • PDF

Analysis on Propagation Characteristics and Experimental Verification of $A_1$ Circumferential Waves in Nuclear Fuel Rods Coated with Oxide Layers (산화막 피복 원전 연료봉에서 $A_1$ 원주파의 전파 특성 해석과 실험적 검증)

  • Joo, Young-Sang;Ih, Jeong-Guon;Jung, Hyun-Kyu;Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.189-199
    • /
    • 1999
  • The resonance scattering of acoustic waves from the cylindrical shells of nuclear fuel rods coated with oxide layers has been theoretically modeled and numerically analyzed for the propagation characteristics of the circumferential waves. The normal mode solutions of the scattering pressure of the coated shells have been obtained. The pure resonance components have been isolated using the newly proposed inherent background coefficients. The propagation characteristics of resonant circumferential waves for the shells coated with oxide layers are affected by the presence and the thickness of an oxide layer. The characteristics have been experimentally confirmed through the method of isolation and identification of resonances. The change of the phase velocity of the $A_1$ circumferential wave mode for the coated shell is negligible at the specified partial waves in spite of the presence of the oxide layer and the increase in coating thickness. Utilizing the invariability characteristics of the phase velocity of the $A_1$ mode, the oxide layer thickness of the coated shells can be estimated. A new nondestructive technique for the relative measurement of the coating thickness of coated shells has been proposed.

  • PDF

Development of Thermo-Cosmetics Using Photothermal Effect of Gold Nanoparticles (금 나노입자의 광열효과를 이용한 온열화장품 개발)

  • Lee, Jae-Yeul;Kim, Bo-Mi;Park, Se-Ho;Choi, Yo-Han;Shim, Kyu-Dong;Moon, Sung-Bae;Jang, Eue-Soon;Yang, Seun-Ah;Jhee, Kwang-Hwan
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • Many applications of nanoparticles have been developed since 1970s. Surface plasmon resonance (SPR) effect can be generated at the surface of nanoparticles by illumination. SPR is the resonant oscillation of conduction electrons at the surface material stimulated by incident light. The collisions between excited electrons and metal atoms can cause the production of thermal energy (photothermal effect). Here, we presented the development of thermo-cosmetics using photothermal effect of gold nanoparticles. Gold nanoparticles (GNPs) were chosen for it's low toxicity. We also and investigated the cell biocompatibility and heating effectiveness for photothermal effect of GNPs. Synthesized GNPs were verified by UV-vis spectrophotometer, where GNP has a characteristic absorbance spectrum. Concentration of GNP was measured by atomic absorption analyzer. The cytotoxicity was confirmed by MTT assay and double staining assay. Photothermal effect of GNP was demonstrated by the thermal increasing properties depending on GNP concentration, which was taken by an IR-thermal camera with a xenon lamp as the light source. If the thermal effect of GNP is applied for thermo-cosmetics, it can supply heat to skin by converting solar energy into thermal energy. Thus, cosmetics containing GNPs can provide benefits to people in the cold region or winter season for maintaining skin temperature, which lead to a positive effect on skin health.

Study on Assessment and Treatment Patterns of Speech-Language Pathologists in Pediatric Vocal Problem Through Multicenter Survey (다기관 설문조사를 통한 국내 소아 음성질환 환자의 검사 및 치료 유형 연구)

  • Lee, Jong-Geun;Bang, Seung-Hwan;Jeon, Jae-Min;Lee, Jung-Kyu;Kim, Angela Yun;Woo, Jeong-Soo;Cho, Jae-Gu
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.1
    • /
    • pp.39-47
    • /
    • 2019
  • Background and Objectives : Pediatric vocal health problems are relatively common. However, it is not yet well studied whether uniform diagnosis and treatment is done properly in South Korea. The purpose of this study was to investigate the methods that the Korean speech therapists use to diagnose and treat pediatric voice problem. Materials and Method : An anonymous online questionnaire was administered to 32 speech language therapists registered at the Korean laryngeal speech linguistics society detailing demographics, employment institution, general management of pediatric patients with vocal problem including assessment and treatment procedures. Results : Current practice patterns were analyzed on 32 speech language therapists providing services in South Korea mostly working at tertiary university hospital. One third of pediatric patients were assessed without proceeding to treatment. One fifth of patients were treated without assessment. Perceptual assessment was the main pretreatment assessment methods used. Treatment was done in the following order : Voice rest, SOVT, yawn-sigh and resonant voice. Post-treatment evaluation was used in the following order : Instrumental assessment, clinical judgment, and recording comparison. Conclusion : Speech language therapists practice in South Korea mostly follows the ASHA practice guidelines. However, there are still great amount of cases in which only the evaluation was done without appropriate treatment. Further research is needed to make SPLs more systematic and efficient for evaluating and treating pediatric vocal patients.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Analysis of acoustic emission parameters according to failure of rock specimens (암석시편 파괴에 따른 acoustic emission 특성인자 분석)

  • Lee, Jong-Won;Oh, Tae-Min;Kim, Hyunwoo;Kim, Min-Jun;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.657-673
    • /
    • 2019
  • A monitoring method based on acoustic emission (AE) sensor has been widely used to evaluate the damage of structures in underground rock. The acoustic emission signal generated from cracking in material is analyzed as various acoustic emission parameters in time and frequency domain. To investigate from initial crack generation to final failure of rock material, it is important to understand the characteristics of acoustic emission parameters according to the stress ratio and rock strength. In this study, uniaxial compression tests were performed using very strong and weak rock specimen in order to investigate the acoustic emission parameters when the failure of specimen occurred. In the results of experimental tests, the event, root-mean-square (RMS) voltage, amplitude, and absolute energy of very strong rock specimen were larger than those of the weak rock specimen with an increase of stress ratio. In addition, the acoustic emission parameters related in frequency were more affected by specification (e.g., operation and resonant frequency) of sensors than the stress ratio or rock strength. It is expected that this study may be meaningful for evaluating the damage of underground rock when the health monitoring based on the acoustic emission technique will be performed.

Characteristics of Dynamic Parameter of Sandy Soil According to Grout Injection Ratio (그라우트 주입율 변화에 따른 사질토의 동적계수 특성)

  • Ahn, Kwangkuk;Park, Junyoung;Oh, Jonggeun;Lee, Jundae;Han, Kihwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.5
    • /
    • pp.59-63
    • /
    • 2011
  • Ground dynamic parameter such as shear elastic modulus and damping ratio is a very important variable in design of ground-structure with repeated load and dynamic load. Shear elastic modulus and damping ratio on small strain below linear limit strain is constant regardless of strain. Shear elastic modulus as the maximum shear elastic modulus and damping ratio as the minimum damping ratio were considered. As a lot of experiment related to the maximum shear elastic modulus, which is in dynamic deformation characteristics, have been conducted, many factors including voiding ratio, over consolidation ratio(OCR), confining pressure, geology time, PI, and the number of load cycle affect to dynamic soil characteristic. However, the research of ground dynamic characteristic improved with grout is absent such as underground continuous wall construction, deep mixing method, umbrella arch method. In order to investigate the dynamic soil characteristics improved with grout, in this study, resonant column tests were performed with changing water content(20%, 25%, 30%) and injection ratio of grout(5%, 10%, 15%), cure time(7th day, 28th day) As a result, shear elastic modulus and damping ratio, which are ground dynamic parameter, are affected by the injection ratio of milk grout, cure time and water content.

The Power Converter Circuit Characteristics for 3 kW Wireless Power Transmission (3 kW 무선 전력전송을 위한 전력 변환기 회로 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Kim, Jin Sun;Kang, Jin-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2020
  • In a wireless power transmitter, the characteristics and effects of wireless power transmission between two induction coils are investigated, and a power converter circuit and a battery charger/discharger circuit using wireless power transmission technology are proposed. The advantage of wireless power transmitters and wireless chargers is that, instead of the existing plug-in-mounted wired charger (OBC; on-board charger), the user can wirelessly charge the battery without connecting the power source when charging power to the battery. There is. In addition, the advantage of wireless charging can bring about an energy efficiency improvement effect by using the secondary side rectifier circuit and the receiving coil, but the large-capacity long-distance wireless charging method has a limitation on the transmission distance, so many studies are currently being conducted. The purpose of the study is to study the transmitter circuit and receiver circuit of a wireless power transmission device using a primary coil, a secondary coil, and a half bridge series resonance converter, which can transmit power of a non-contact type power transmitter. As a result, a new topology was applied to improve the power transmission distance of the wireless charging system, and through an experiment according to each distance, the maximum efficiency (95.8%) was confirmed at an output of 3 kW at an 8 cm transmission distance.