• Title/Summary/Keyword: resonance signal

Search Result 1,068, Processing Time 0.023 seconds

A Study of Signal Intensity of MRA in Flow Phantom of Fusiform Aneurysm (방추형 동맥류 모형에서 자기공명 혈관조영술의 신호강도에 대한 연구)

  • 한기석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 1998
  • Purpose : Authors correlated the three-dimensional time-of-flight MRA signal intensity characteristics and flow profile simulated by computer in an experimental flow phantom model. Materials and Methods : The three-dimensional time-of-flight MRA was performed in a fusiform flow phantom and analyzed the flow signal. computer assisted flow simulation was performed in same flow geometry. The MRA signal intensity and flow velocity distribution and direction was compared. Results : The flow was depicted as homogeneous signal internsity in inlet and outlet area and inhomogeneous signal intensity in fusiform area. Typically, the flow was depicted as target appearance in transition area to outlet. Whereas mean signal internsity decreased slowly in fusiform area, it rapidly dropped and resumed in transition area to outlet. In computer assisted flow simulation, Whereas there were flow velocity decrease and flow direction change to peripheral in entrance to fusiform area, ther were rapid flow velocity resuming and flow direction change to central in transition area to outlet. Conclusion : The signal loss and target appearance in transition area to outlet is characteristic of fusiform flow. These signal changes correlate with abrupt flow velocity and direction change well.

  • PDF

Synovial Lesions with Low Signal Intensities on T2-Weighted MR Image (T2 강조 MR 영상에서 저신호강도를 보이는 윤활막 질환)

  • Choo, Hye-Jung;Lee, Sun-Joo;Cho, Kil-Ho;Suh, Kyung-Jin;Lee, Sung-Moon;Lee, Young-Hwan;Lee, In-Sook;Lee, Gyung-Kyu;Kim, Bo-Mi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Pigmented villonodular synovitis, synovial chondromatosis, long-standing rheumatoid arthritis, hemophilic arthropathy, chronic tophaceous gout, amyloid arthropathy, tuberculous arthritis, and hemangioma are the synovial diseases showing low signal intensity on T2-weighted image. Synovial deposition of hemosiderin, urate, and amyloid and fibrosis or caseous necrosis of hypertrophied synovium are known as the pathologic causes of T2 signal intensity. Because of the low incidence of the synovial lesions showing T2 low signal intensity, recognition of these diseases would be helpful for the exact diagnosis.

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • Jung, Sang Hoon;Yu, Jeong Il;Park, Hee Chul;Lim, Do Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.64-75
    • /
    • 2016
  • Purpose: In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. Materials and Methods: In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. Results: The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median $R^2$ of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Conclusion: Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer.

Effective Power/Ground Network Design Techniques to suppress Resonance Effects in High-Speed/High-Density VLSI Circuits (고속/고밀도 VLSI 회로의 공진현상을 감소시키기 위한 효율적인 파워/그라운드 네트워크 설계)

  • Ryu Soon-Keol;Eo Yung-Seon;Shim Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.29-37
    • /
    • 2006
  • This paper presents a new analytical model to suppress RLC resonance effects which inevitably occur in power/ground lines due to on-chip decoupling capacitor and other interconnect circuit parasitics (i.e., package inductance, on-chip decoupling capacitor, and output drivers, etc.). To characterize the resonance effects, the resonance frequency of the circuit is accurately estimated in an analytical manner. Thereby, a decoupling capacitor size to suppress the resonance for a suitable circuit operation is accurately determined by using the estimated resonance frequency. The developed novel design methodology is verified by using $0.18{\mu}m$ process-based-HSPICE simulation.

An Optimal Damping Control Algorithm of Direct Two-level Inverter for Miniaturization and Weight Reduction of Auxiliary Power Supply on Railway Vehicle

  • Lee, Chang-hee;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2335-2343
    • /
    • 2018
  • This paper proposes an optimal damping control algorithm of the DTI (Direct Two-level Inverter) to miniaturize and reduce the weight of auxiliary power supply for railway vehicles. The conventional auxiliary power supply for railway vehicles uses a DC-DC converter to maintain the inverter input power from the line voltage smoothly. The proposed topology does not use a DC-DC converter for reducing of manufacturing and maintenance costs. It also proposes a DTI topology removed damping resistors that generate ground signal noise in a certain period. At this time, a resonance phenomenon of DC-link voltage occurs due to variation of the inductive load, and a method of controlling the resonance phenomenon of DC-link voltage is required. In order to suppress the resonance phenomenon of the DC-link voltage, at a point before resonance occurs, this paper introduces an algorithm to suppress the resonance phenomenon of DC-link voltage by compensating the resonance component of the q axis voltage of the synchronous reference frame. The proposed algorithm verifies the effect through simulation and experiment.

Analysis of Magnetic Resonance Characteristics and Images of Korean Red Ginseng (홍삼의 자기공명 특성과 영상 분석)

  • 김성민;임종국
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.253-260
    • /
    • 2003
  • In this study, the feasibility of magnetic resonance techniques for nondestructive internal quality evaluation of Korean red ginseng was examined. Relaxation time constants were measured using various grades of red ginsengs. Solid state magnetic resonance imaging technique was applied to image dried red ginsengs which have low moisture contents (about 13%). A 7 tesla magnetic resonance imaging system operating at a proton resonant frequency of 300 ㎒ was used for acquiring MR images of dried Korean red ginseng. The comparison test of cross cut digital images and magnetic resonance images of heaven grade, good grade with cavity inside, and good grade with white part inside red ginseng suggested the feasibility of the internal quality evaluation of Korean red ginsengs using MRI techniques. A good grade red ginseng included abnormal tissues such as cavities or white parts inside was observed by the signal intensity of MR image based on magnetic resonance properties of proton nucleus. Analysis on an one dimensional profile of acquired MR image of Korean red ginseng showed easy discrimination of normal and abnormal tissues. MR techniques suggested ways to detect internal defects of red ginsengs effectively.

LONGITUDINAL WAVES, STORING AND AMPLIFYING CAPABILITY OF INFORMATION IN WATER MOLECULES AND QUANTUM RESONANCE SPECTROMETER

  • Oh, Hung-Kuk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.18-28
    • /
    • 1996
  • The outer-most electrons of metal atoms and the remaining valence electrons of any molecular atoms make three-dimensional crystallizing $\pi$-bondings. The rotating electrons on the three-dimensional crystallizing $\pi$-bonding orbitals of atoms make $\pi$-far infrared rays. Longitudinal wave is a propagation of a bundle of $\pi$-far infrared rays, which are produced by a dynamic impact on a solid bar. The $\pi$-far infrared rays make three-dimensional crystallizing $\pi$-bondings in the material, which reproduce the same $\pi$-far infrared rays. If a current signal is input into water molecules under a given electric potential field with $\pi$-far infrared rays (input information), the signal can be amplified because the $\pi$-far infrared rays make the $\pi$-bondings, which reduce electric resistance. The three-dimensional crystallizing $\pi$-bondings can induce normal electrons to move from one orbital to next one with a aid of potential electric field. Quantum Resonance Spectrometer is composed of tesla coil absorbing $\pi$-far infrared rays, tesla coil emitting varying electromagnetic waves signal generator, signal storage, human body amplifier, signal analyzer and data indicator. The absorbing tesla coil making varying magnetic field and downward and upward electric field, which resonates the $\pi$-far infrared rays coming out from specimen and absorbs them. The modulated current signal from the input square signal can generate and emit varying electromagnetic waves from the tesla coil. The varying electro-magnetic waves make the three-dimensional crystallizing $\pi$-bondings and the $\pi$-far infrared rays in the water molecules.

  • PDF

Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy

  • Sang Hyup Lee;Hye Jin Yoo;Seung-Man Yu;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.126-133
    • /
    • 2019
  • Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm3 voxel was placed within the normal L2 or L3 vertebral body, or other lesions including a compression fracture or metastasis. The bone marrow fat spectrum was characterized on the basis of the magnitude of measurable fat peaks and a priori knowledge of the chemical structure of triglycerides. The imaging-based fat-signal fraction results were then compared to the MRS-based results. Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R2 = 0.88, p < 0.001). In Bland-Altman analysis, 92.0% (23/25) of the data points were within the limits of agreement. Bland-Altman plots revealed a slight but systematic error in the m-Dixon based fat-signal fraction, which showed a prevailing overestimation of small fat-signal fractions (< 20%) and underestimation of high fat-signal fractions (> 20%). Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.

The Pallidal Index in Patients with Acute-on-Chronic Liver Disease: Is It a Predictor of Severe Hepatic Encephalopathy?

  • Lee, Dong Hyun;Lee, Hui Joong;Hahm, Myong Hun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.125-130
    • /
    • 2017
  • Purpose: To evaluate the clinical significance of T1 high signal intensity on the globus pallidus as a predictor of severe hepatic encephalopathy in patients with acute-on-chronic liver failure (ACLF), which is a distinct syndrome characterized by multi-organ dysfunction including cerebral failure. Materials and Methods: From January 2002 to April 2014, we retrospectively reviewed the magnetic resonance imaging (MRI) findings and clinical and magnetic resonance (MR) features of 74 consecutive patients (44 men and 30 women; mean age, 59.5 years) with liver cirrhosis. The chronic liver failure-sequential organ failure assessment score was used to diagnose ACLF. The pallidal index (PI), calculated by dividing the mean signal intensity of the globus pallidus by that of the subcortical frontal white matter were compared according to ACLF. The PI was compared with the Model for End-Stage Liver Disease (MELD) score in predicting the development of ACLF. Results: Fifteen patients who were diagnosed with ACLF had higher hepatic encephalopathy grades (initial, P = 0.024; follow-up, P = 0.002), MELD scores (P < 0.001), and PI (P = 0.048). In the ACLF group, the mean PI in patients with cerebral failure was significantly higher than that in the patients without cerebral failure (1.33 vs. 1.20, P = 0.039). In patients with ACLF, the area under the curve (AUC) for PI was 0.680 (95% confidence intervals [CI], 0.52-0.85), which was significantly lower than that for the MELD score (AUC, 0.88; 95% CI, 0.77-0.99) (P = 0.04). Conclusion: The PI can be an ancillary biomarker for predicting the development of ACLF and severe hepatic encephalopathy.

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.