• Title/Summary/Keyword: resonance signal

Search Result 1,070, Processing Time 0.033 seconds

The Electric Field Dependence of the Resonance Characteristics and Piezoelectric Constant of the PZT-PMNS Ceramics (PZT-PMNS 세라믹의 공진특성 및 압전 정수의 전계의존성)

  • Oh, Jin-Heon;Lim, Kee-Joe;Kang, Seong-Hwa;Kim, Hyeon-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.179-180
    • /
    • 2008
  • In this paper, the variable tendency piezoelectric constant and resonance characteristics piezoelectric ceramics due to the electric field is studied. The practical application of piezoelectric ceramics is not only applied in field of small signal. For example, in case of an ultrasonic motor, $120{\sim}130Vrms$ of driving voltage is needed and that of an piezoelectric pump, $200{\sim}220Vrms$ of voltage is required. Therefore, to examine the characteristics of piezoelectric ceramics in large signal contributes to reducing the susceptibility to the multifarious application and securing the ease of the production of control circuit. These contributions may be connected to the expansion of industrial application. We fabricated disk-type piezoelectric ceramic samples by using conventional method and measured the resonance characteristics of these samples under from low to high voltage driving conditions. According to increasing the value of the input voltage, we measured the resonance frequency of the piezoelectric ceramic, and inquired into the cause of these phenomena.

  • PDF

Chordoid Glioma Originating in the Intrasellar and Suprasellar Regions: Case Report

  • Hwang, Jisun;Lee, Aleum;Chang, Kee-Hyun;Moon, Ah Rim;Hwang, Sun-Chul;Hong, Hyun Sook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.117-121
    • /
    • 2015
  • Chordoid glioma is a rare, low-grade brain neoplasm typically located in the third ventricle. Herein, we report an unusual case of histologically confirmed chordoid glioma located in the pituitary fossa and suprasellar region, not attached to the third ventricle. A 57-year-old woman presented with a 2-month history of headache and visual disturbance. Magnetic resonance imaging revealed an ovoid mass in the pituitary fossa and suprasellar region, compressing the optic chiasm without involvement of the third ventricle. The tumor showed low signal intensity on T1-weighted images and iso- to high signal intensity on T2-weighted images, with strong and homogenous contrast enhancement. Subtotal resection was performed via the transcranial approach, and the patient subsequently received adjuvant gamma knife radiosurgery. However, the residual mass showed disease progression 5 months after the initial surgery.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Hypointensity on Susceptibility-Weighted Images Prior to Signal Change on Diffusion-Weighted Images in a Hyperacute Ischemic Infarction: a Case Study

  • Kim, Dajung;Lee, Hyeonbin;Jung, Jin-Man;Lee, Young Hen;Seo, Hyung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.131-134
    • /
    • 2018
  • Susceptibility-weighted imaging (SWI) is well known for detecting the presence of hemorrhagic transformation, microbleeds and the susceptibility of vessel signs in acute ischemic stroke. But in some cases, it can provide the tissue perfusion state as well. We describe a case of a patient with hyperacute ischemic infarction that had a slightly hypodense, patchy lesion at the left thalamus on the initial SWI, with a left proximal posterior cerebral artery occlusion on a magnetic resonance (MR) angiography and delayed time-to-peak on an MR perfusion performed two hours after symptom onset. No obvious abnormal signals at any intensity were found on the initial diffusion-weighted imaging (DWI). On a follow-up MR image (MRI), an acute ischemic infarction was seen on DWI, which is the same location as the lesion on SWI. The hypointensity on the initial SWI reflects the susceptibility artifact caused by an increased deoxyhemoglobin in the affected tissue and vessels, which reflects the hypoperfusion state due to decreasing arterial flow. It precedes the signal change on DWI that reflects a cytotoxic edema. This case highlights that, in some hyperacute stages of ischemic stroke, hypointensity on an SWI may be a finding before the hyperintensity is seen on a DWI.

Early Diagnosis of Aseptic Meningitis in Ramsay Hunt Syndrome on 10-Minute Delayed CE 3D FLAIR Image: a Case Report

  • Kang, Mi Hyun;Kim, Da Mi;Lee, In Ho;Song, Chang June
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.197-200
    • /
    • 2021
  • Ramsay Hunt syndrome (RHS) is a disease caused by varicella-zoster virus (VZV) infection that can be diagnosed through clinical symptoms with or without imaging evaluations. The typical features of RHS on imaging evaluation include signal changes and enhancement in the internal auditory canal (IAC) nerves, and the labyrinthine segment of cranial nerve VII (CN VII) and cranial nerve VIII (CN VIII). In some patients, inner ear structure (cochlear and vestibular apparatus) is involved in RHS. Neurologic complications, such as encephalitis and meningitis, are rare in RHS, but are known to occur. Therefore, magnetic resonance imaging (MRI) is necessary to detect both abnormal signal intensity in the IAC, CN VII, CN VIII, inner and ear structure, and CNS complications. We report an RHS patient with CN VII, VIII, and leptomeningeal enhancement within the cerebellar folia on 10-min delayed, contrast-enhanced (CE), three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging.

Pallidal Signal Intensities on T1-weighted MRI are Highly Observed in Advanced Liver Cirrhosis

  • Weon, Young-Cheol;Park, Neung-Hwa;Kim, Yang-Ho;Lee, Heun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.380-385
    • /
    • 2012
  • Background: Manganese (Mn) has been found to increase the signal intensity of the globus pallidus (GP) on T1-weighted magnetic resonance images (MRI). We performed this study in order to determine the features of liver disease that correlate with pallidal signal intensities. Methods: We assessed blood Mn levels and pallidal signals in T1-weighted MRI in 49 patients with liver cirrhosis and 23 healthy controls. Results: Increased signal intensity in the GP was observed in 30 of 49 (61.2%) patients with liver cirrhosis, with the pallidal index (PI) in patients with Child-Pugh classes B and C differing significantly from the PI in controls. Multiple linear regression analysis showed that blood Mn concentrations and Child-Pugh scores in cirrhotics were significantly associated with increased PI after controlling for other confounders (p<0.05 each). Conclusions: Pallidal signals on T1-weighted MRI are mainly observed in advanced liver cirrhosis. The present study suggests that advanced liver cirrhosis may be a human model for manganism.

RF Integrated Electromagnetic-Noise Filters Incorporated with Nano-granular Co41Fe38AI13O8 Soft Magnetic Thin Films on Coplanar Transmission Line

  • Sohn, Jae-Cheon;Yamaguchi Masahiro;Lim, Sang-Ho;Han, Suk-Hee
    • Journal of Magnetics
    • /
    • v.10 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • The RF integrated noise filters are fabricated by photolithography. The stack for the electromagnetic noise filters consists of the nano-granular ($Co_{41}Fe_{38}AI_{13}O_8$) soft magnetic film / $SiO_2$ / Cu transmission line / seed layer (Cu/Ti) / $SiO_2$-substrate. A good signal-attenuation feature along with a low signal-reflection feature is observed in the present filters. Especially in the noise filter incorporated with a $Co_{41}Fe_{38}AI_{13}O_8$ magnetic film with lateral dimensions of $2000{\mu}m$ wide, 15 mm long and $1{\mu}m$ thick, the maximum magnitude of signal attenuation reaches -55 dB, and the magnitude of signal reflection is below -10 dB in the overall frequency range. And this level of signal attenuation is much larger than that of a noise filter incorporated with a Fe magnetic film.

Characteristics of MnxSi1-xTe Compound Studied by Electron Magnetic Resonance and Other Experiments

  • Na, Sung-Ho;Kim, Heung-Chul;Park, Jung-Woo;Kim, Jang-Whan
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • The magnetic and other physical characteristics of $Mn_xSi_{1-x}Te$ have been investigated by electron magnetic resonance (EMR), X-ray diffraction (XRD) and other experiments. $Mn_xSi_{1-x}Te$ is found to have corundum structure for manganese contents up to 10% and also to be ferromagnetic for temperatures below 80 K. While ferromagnetic resonance signal coexists with the usual paramagnetic resonance signal, invariance of the g-factor inferred from the electron paramagnetic resonance signals throughout all temperature ranges clearly confirms that the manganese ions are in the electronic 3d5 state. The temperature dependence of EMR line-width is the same as other diluted magnetic semiconductors. From the EMR signals relaxation times $T_2$ and $T_1$ of $Mn_xSi_{1-x}Te$ compounds are estimated to be about $4.4{\times}10^{-10}s$ and $9.3{\times}10^{-8}s$ respectively and are found to vary slightly with temperature or composition change. Exchange narrowing of the EMR line-width becomes dominant for the sample in which the substitution ratio, x = 30%. For one sample, in which x = 0.5%, spin glass-like behavior is indicated by EMR signals for temperatures lower than 60 K. This behavior may authentic for samples within a certain range of x.

Characterization and Identification of Gamma-Irradiated Kimchi Cabbage and Broccoli by Electron Spin Resonance Spectroscopy using Different Sample Pre-treatments (감마선 조사된 배추 및 브로콜리의 전처리방법에 따른 전자스핀공명분석 특성)

  • Kwak, Ji-Young;Ahn, Jae-Jun;Akram, Kashif;Kim, Gui-Ran;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.532-539
    • /
    • 2012
  • Electron spin resonance (ESR) spectroscopy of gamma-irradiated fresh broccoli and kimchi cabbage was conducted to identify their irradiation history. Different pretreatments, such as freeze-drying (FD), oven-drying (OD), alcoholic-drying (ALD), and water-washing and alcoholic-drying (WAD) were used to lower the moisture contents of the samples prior to ESR analysis. The non-irradiated samples exhibited a single central signal ($g_0$=2.0007) with clear effect of $Mn^{2+}$, especially in kimchi cabbage. Upon irradiation, there was an increase in the intensity of the central signal, and two side peaks, mutually spaced at 6 mT, were also observed. These side peaks with $g_1$ (left)=2.023 and $g_2$ (right)=1.985 were attributed to radiation-induced cellulose radicals. Leaf and stem in broccoli, and root and stem in kimchi cabbage provided good ESR signal responses upon irradiation. The signal noise was reduced in case of ALD and WAD pretreatments, particularly due to $Mn^{2+}$ signals. The ALD treatment was found most feasible to detect the improved ESR spectra in the irradiated samples.

Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses (SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.