Magnetic Field Standards Using Magnetic Resonance

  • Park, Po Gyu;Kim, Wan-Seop;Joo, Sung Jung;Lee, Hyung Kew
    • 한국자기공명학회논문지
    • /
    • 제21권1호
    • /
    • pp.7-12
    • /
    • 2017
  • The nuclear magnetic resonance (NMR) and atomic magnetic resonance (AMR) plays a fundamental role in achieving a high accuracy of magnetic field measurements. Magnetic field unit (T) was realized based on the shielded proton gyromagnetic ratio (${\gamma}^{\prime}_P$), helium-4 gyromagnetic ratio (${\gamma}_{4He}$) and related techniques. The magnetic field standard system has been disseminated by the NMR magnetometer and electromagnet, a Helmholtz coil system, and AMR magnetometer in the nonmagnetic laboratory. A magnetic field standard below 1 mT has been developed by using Cs and Cs- $^4He$ AMR with automatic compensation of an external magnetic field noise. The standards serve for the calibration of magnetometers and support the test of sensors and materials in the range from $5{\mu}T$ to 2.0 T with (1 to 50) ${\mu}T/T$ uncertainty (k=2).

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

ECR 용 최적 마그네트에 관한 연구 (A Study on the Optimal Magnet for ECR)

  • 김윤택;김용주;김교순;이용직;손명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.649-652
    • /
    • 1992
  • ECR(Electron Cyclotron Resonance) occure at ${\omega}_c$=${\omega}$, ${\omega}_c$:electron cycltron frequency, ${\omega}$:electromagnetic wave frequency. ECR system have several merit, 1) power transefer efficiency 2) low neutral gas pressure (below 1 mTorr) 3) high plasma density($10^{12}$ $cm^{-3}$). It is applicated variously in the field of semiconductor and new materials as the manufacturing equipment. Magnetic field in ECR system contruct resonance layer (${\omega}$=2.45GHz, $B_z$=875 Gauss) and control plasma. Plasma is almost generated at resonance layer. If the distance between substrate and resonance layer is short, uniformity of plasma is related with profile of resonance layer. Plasma have the property "Cold in Field", so directonality of magnetic field is one of the control factors of anisotropic etching. In this study, we calculate B field and flux line distribution, optimize geometry and submagnet current and improve of magnetic field directionality (99.9%) near substrate. For the purpose of calculation, vector potential A(r,z) and magnetic field B(r,z), green function and numerical integration is used. Object function for submagnet optimization is magnetic field directionality on the substrate and Powell method is used as optimization skim.

  • PDF

Ferromagnetic resonance of Hensler $Ni_2$MnGa thin films

  • M. D. Huang;Lee, N. N.;Lee, Y. P.;J. Y. Rhee;J. Dubowik
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.116-119
    • /
    • 2003
  • $Ni_2$MnGa films, deposited on mica and glass substrates, were studied by ferromagnetic resonance (FMR) technology. The temperature-dependent resonance field was measured and a martensitic phase transformation (MT) was found between 310 and 340 K, exhibiting an abnormality on the curve. The easy axis is found to be in the film plane. The line width increases as a whole with decreasing temperature, which is discussed in terms of the motional narrowing mechanism. The resonance field was also measured as a function of orientation and the results were fitted, exhibiting a good consistence.

Magnetic dependence of cyclotron resonance in the electron-piezoelectric phonon interacting materials

  • Park, Jung-Il;Sug, Joung-Young
    • 한국자기공명학회논문지
    • /
    • 제24권1호
    • /
    • pp.16-22
    • /
    • 2020
  • Based on quantum transport theory, we investigated theoretically the magnetic field dependence of the quantum optical transition of quasi 2-dimensional Landau splitting system, in CdS and ZnO Through the analysis of the current work, we found the increasing properties of the cyclotron resonance line-profiles (CRLPs) which show the absorption power and the cyclotron resonance line-widths (CRLWs) with the magnetic field in CdS and ZnO We also found that that CRLWs, γtotal(B) of CdS < γtotal(B) of ZnO in the magnetic field region B < 15 Tesla.

Spin orbit torque detected by spin torque FMR in W/CoFeB bilayer

  • Kim, Changsoo;Moon, Kyoung-Woong;Chun, Byong Sun;Kim, Dongseok;Hwang, Chanyong
    • 한국자기공명학회논문지
    • /
    • 제23권2호
    • /
    • pp.46-50
    • /
    • 2019
  • Spin orbit torque would be applied as the next generation of MRAM, so many researchers are interested in related field. To make a more efficient device, electric current should convert into spin current with high efficiency. Moreover, it becomes important to measure efficiency of spin orbit torque accurately. We measured spin torque FMR of W/CoFeB hetero structure system with direct current. The efficiencies of the damping like torque and field like torque were measured by using the linewidth and on-resonance field proportional to direct current. In addition, we analyzed that a quadratic shift of the on-response field was caused by the Joule heating.

Partial Solution for Concomitant Gradient Field in Ultra-low Magnetic Field: Correction of Distortion Artifact

  • Lee, Seong-Joo;Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제24권3호
    • /
    • pp.66-69
    • /
    • 2020
  • In ultra-low field magnetic resonance imaging (ULF-MRI), the strength of a static magnetic field can be comparable to that of gradient field. On that occasion, the gradient field is accompanied by concomitant gradient field, which yields distortion and blurring artifacts on MR images. Here, we focused on the distortion artifact and derived the equations capable of correcting it. Its usefulness was confirmed through the corrections in both simulated and experimental images. This solution will be effective for acquiring more accurate images in low and/or ultra-low magnetic fields.

Computer Interface를 이용한 핵 사중극 공명 Gaussmeter의 제작 (Construction of the NQR Gaussmeter using Computer Interface)

  • 김혜진;신종필;조성호;김창석
    • 한국자기학회지
    • /
    • 제5권2호
    • /
    • pp.99-102
    • /
    • 1995
  • 전기장 기울기 텐서가 축대칭인 결정에 대칭인 방향으로 자기장을 가하면 핵사중극공명에 미치는 Zeeman 효과에 의하여 두 개의 분리된 공명진동수가 측정된다. 이 때 가해준 자기장과 두 공명진동수 간의 차이는 서로 비례하며, ${(CH_{2})}_{6}N_{4}$ 단결정의 $^{14}N$ 원자핵에 대한 비례상수는 0.16 mT/kHz 이다. 핵 사중극 공명장치 와 개인용 컴퓨터를 interface 하여 핵 사중극 공명신호의 모습을 모니터에 표시하여 측정되는 두 공명신호의 진동수 차이로 자기장을 직접 읽을 수 있도록 하였다. 여기로부터 핵 사중극 공명 Gaussmeter를 이용하여 실험적으로 측정한 최저 자기장은 0.20 mT 였다.

  • PDF

Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.213-217
    • /
    • 2008
  • The flux-lock type superconducting fault current limiter(SFCL) can apply the magnetic field into the high-$T_C$ superconducting(HTSC) element by adopting the magnetic field coil in its third winding. To apply the magnetic field into the HTSC element effectively, the capacitor for LC resonance is connected in series with the magnetic field coil. However, the current waveform of third winding for the application of the magnetic field is affected by the LC resonance condition for the frequency of the source voltage and can affect the waveform of the limited fault current. In this paper, the current waveform of the third winding in the flux-lock type SFCL according to LC resonance condition during a fault period was analyzed. From the differential equation for its electrical circuit, the current equation of the third winding was derived and described with the natural frequency and the damping ratio as design parameters. Through the analysis according to the design parameters of the third winding, the waveform of the limited fault current was confirmed to be influenced by the current waveform of the third winding and the design condition for the stable fault current limiting operation of this SFCL was obtained.

Review of Recent Advancement of Ultra High Field Magnetic Resonance Imaging: from Anatomy to Tractography

  • Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: Advances of magnetic resonance imaging (MRI), especially that of the Ultra-High Field (UHF) MRI will be reviewed. Materials and Methods: Diffusion MRI data was obtained from a healthy adult young male of age 30 using a 7.0T research MRI scanner (Magnetom, Siemens) with 40 mT/m maximum gradient field. The specific imaging parameters used for the data acquisition were a single shot DW echo planar imaging. Results: Three areas of the imaging experiments are focused on for the study, namely the anatomy, angiography, and tractography. Conclusion: It is envisioned that, in near future, there will be more 7.0T MRIs for brain research and explosive clinical application research will also be developed, for example in the area of connectomics in neuroscience and clinical neurology and neurosurgery.