• Title/Summary/Keyword: resonance evaluation

Search Result 847, Processing Time 0.027 seconds

Evaluation of Image Usability by SEMAC Turbo Factor Change using Susceptibility Artifact Reduction (Susceptibility Artifact를 감소시키는 SEMAC 사용 시 Turbo Factor 변화에 따른 영상의 유용성 평가)

  • Choi, Young-Jae;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • The study analyzes Non SEMAC and SEMAC to reduce susceptibility artifacts that may occur when performing magnetic resonance imaging(MRI) of metal patients. The Foot and Ankle Phantom was used as the experimental tool and the 3.8 cm general screw was used to make the magnetic susceptibility artifact. The experimental equipment was used 3.0T Magnetom Skyra and the area was measured with the 17th image where the signal off is the most noticeable in the obtained image. Statistical analysis was performed using the SPSS(Ver.25) program and the significance was assessed by the Wilcoxon Signed Rank Test. As a result, the area of Non SEMAC which is the lowest signal was $289.53{\pm}23.07197mm$. When the Turbo Factor was changed to 3, 4, and 5 after SEMAC use, it decreased to $125.02{\pm}7.45875mm$, $120.96{\pm}12.01704mm$ and $108.79{\pm}16.53498mm$, respectively. In conclusion, this study demonstrates that Using SEMAC with Turbo Factor effectively reduces the susceptibility artifacts.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Seismic Performance Evaluation of Concrete Anchors used in Power Plant Equipment by Shaking Table Tests (진동대 실험을 통한 발전기기용 콘크리트 앵커의 성능평가)

  • Lee, Sang-Moon;Jeon, Bub-Gyu;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • The main purpose of this study is to assess the safety of the fixed anchorages subjected to the seismic motion for an operating facilities in the actual power plant. Thus, the experimental study was conducted to investigate the load response in the event of an actual seismic to the anchorages of a nonstructural components. Since there are economic and spatial constraints to study nonstructural components that actually have various forms, alternative test specimens of steel frames with mass were built and the shaking table test was carried out. In order to evaluate the dynamic characteristics and seismic performance, the natural frequency of the target structure was identified through the shaking table test and then the load response characteristics of the anchorage were evaluated by generating an artificial seismic effect like actual seismic. Finally, the structural stiffness was reinforced by fixing the steel frame to the test specimen using bolts, thereby reducing the load transmitted to the anchorage. It will be carried out on the reliability verification of the experiments and areas that have not been carried out due to the site conditions through the analytical approach in the future.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

Comparative Analysis of Understanding and Satisfaction of MRI Patients after Leaflet Training (리플릿 교육 후 MRI 환자의 이해도 및 만족도 비교분석)

  • Park, Chang-Hee;Han, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.123-129
    • /
    • 2022
  • Recently, the penetration rate of Magnetic Resonance Imaging (MRI) is higher than the average among OECD member countries, and the number of MRI scans is increasing. However, MRI scans take longer than other medical devices, and patient movement must be minimized. Therefore, patient discomfort always follows. When the examination is performed in the discomfort of the patient, it is difficult to perform an accurate examination, and it is difficult to obtain an image of diagnostic value. So, in the past, the patient was asked to read the written guide for the risk and cooperation of MRI, but it was composed of technical terms and difficult-to-understand sentences, so it was difficult to understand. The purpose of this study is to supplement these problems and increase the understanding of MRI scans to help acquire images of diagnostic value. In addition, it is intended to evaluate the excellence of leaflet education by evaluating the understanding and satisfaction of patients. As shown in the results of this study, understanding and satisfaction scores were higher after education than before leaflet education, and it was found that there was a difference in understanding according to academic background. However, there was no difference in the number of MRI scans. That is, there was no difference in the number of inspections due to leaflet education. In the future, leaflet education will be widely used for MRI examination, and it is necessary to study the qualitative evaluation of images after leaflet education in the future.

Prediction of the Natural Frequency of Pile Foundation System in Sand during Earthquake (사질토 지반에 놓인 지진하중을 받는 말뚝 기초 시스템의 고유 진동수 예측)

  • Yang, Eui-Kyu;Kwon, Sun-Yong;Choi, Jung-In;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.1
    • /
    • pp.45-54
    • /
    • 2010
  • It is important to calculate the natural frequency of a piled structure in the design stage in order to prevent resonance-induced damage to the pile foundation and analyze the dynamic behavior of the piled structure during an earthquake. In this paper, a simple but relatively accurate method employing a mass-spring model is presented for the evaluation of the natural frequency of a pile-soil system. Greatly influencing the calculation of the natural frequency of a piled structure, the spring stiffness between a pile and soil was evaluated by using the coefficient of subgrade reaction, the p-y curve, and the subsoil elastic modulus. The resulting natural frequencies were compared with those of 1-g shaking table tests. The comparison showed that the natural frequency of the pile-soil system could be most accurately calculated by constructing a stiffness matrix with the spring stiffness of the Reese (1974) method, which utilizes the coefficient of the subgrade reaction modulus, and Yang's (2009) dynamic p-y backbone curve method. The calculated natural frequencies were within 5% error compared with those of the shaking table tests for the pile system in dry dense sand deposits and 5% to 40% error for the pile system in saturated sand deposits depending on the occurrence of excess pore water pressure in the soil.

Effectiveness of a Wave Resonator under Short-period Waves and Solitary Waves (공진장치를 이용한 단주기파랑과 고립파의 제어)

  • Lee, Kwang Ho;Jeong, Seong Ho;Jeong, Jin Woo;Kim, Do Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1B
    • /
    • pp.89-100
    • /
    • 2010
  • The performance evaluation of a conventional Wave Resonator at the entrance of harbors against solitary wave has been performed using 3D numerical wave flume. A wave resonator has been designed for the attenuation of the transmitted wave energy by trapping the short periodic incident waves only. In this study, however, the controlled performance of the wave resonator by its various widths has been numerically investigated for solitary waves. Source distribution method based on the Green function and the 3D one-field Model for immiscible TWO-Phase flows (TWOPM-3D) using 3D numerical wave flume were used for the short-periodic waves and the solitary waves, respectively, and these models were verified through the comparisons with the previous experimental and numerical results by other researchers. It was confirmed that the wave resonator is effective enough to control the solitary waves as well as the periodic waves when it compares with the case of no resonance system. Further, it was found that there is the optimal width of a wave resonator to attenuate the target solitary waves.

Cerebrovascular Reservoir and Arterial Transit Time Changes Assessed by Acetazolamide-Challenged Multi-Phase Arterial Spin Labeling Perfusion MRI in Chronic Cerebrovascular Steno-Occlusive Disease (만성 뇌혈관 협착폐색증에서 아세타졸아미드 부하 다상 동맥스핀표지 자기공명관류영상으로 평가한 뇌혈류 예비능과 동맥 통과 시간의 변화)

  • Inpyeong Hwang;Chul-Ho Sohn;Keun-Hwa Jung;Eung Koo Yeon;Ji Ye Lee;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Seung Hong Choi;Ji-hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.626-637
    • /
    • 2021
  • Purpose To explore cerebrovascular reservoir (CVR) and arterial transit time (ATT) changes using acetazolamide-challenged multi-phase arterial spin labeling (MP-ASL) perfusion-weighted MRI in chronic cerebrovascular steno-occlusive disease. Materials and Methods This retrospective study enrolled patients with chronic steno-occlusion who underwent acetazolamide-challenged MP-ASL between June 2019 and October 2020. Cerebral blood flow, CVR, basal ATT, and ATT changes associated with severe stenosis, total occlusion, and chronic infarction lesions were compared. Results There were 32 patients (5 with bilateral steno-occlusion) in our study sample. The CVR was significantly reduced during total occlusion compared with severe stenosis (26.2% ± 28.8% vs. 41.4% ± 34.1%, respectively, p = 0.004). The ATT changes were not significantly different (p = 0.717). The CVR was marginally lower in patients with chronic infarction (29.6% ± 39.1% vs. 38.9% ± 28.7%, respectively, p = 0.076). However, the ATT was less shortened in patients with chronic infarction (-54 ± 135 vs. -117 ± 128 ms, respectively, p = 0.013). Conclusion Acetazolamide-challenged MP-ASL provides an MRI-based CVR evaluation tool for chronic steno-occlusive disease.

Improving Diagnostic Performance of MRI for Temporal Lobe Epilepsy With Deep Learning-Based Image Reconstruction in Patients With Suspected Focal Epilepsy

  • Pae Sun Suh;Ji Eun Park;Yun Hwa Roh;Seonok Kim;Mina Jung;Yong Seo Koo;Sang-Ahm Lee;Yangsean Choi;Ho Sung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.4
    • /
    • pp.374-383
    • /
    • 2024
  • Objective: To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learningbased image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). Materials and Methods: This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. Results: The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). Conclusion: The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.