• Title/Summary/Keyword: resonance evaluation

Search Result 834, Processing Time 0.031 seconds

Cytotoxicity and DNA Damage Induced by Magnetic Nanoparticle Silica in L5178Y Cell

  • Kang, Jin-Seok;Yum, Young-Na;Park, Sue-Nie
    • Biomolecules & Therapeutics
    • /
    • v.19 no.2
    • /
    • pp.261-266
    • /
    • 2011
  • As recent reports suggest that nanoparticles may penetrate into cell membrane and effect DNA condition, it is necessary to assay possible cytotoxic and genotoxic risk. Three different sizes of magnetic nanoparticle silica (MNP@$SiO_2$) (50, 100 and 200 nm diameter) were tested for cytotoxicity and DNA damage using L5178Y cell. MNP@$SiO_2$ had constant physicochemical characteristics confirmed by transmission electron microscope, electron spin resonance spectrometer and inductively coupled plasma-atomic emission spectrometer for 48 h. Treatment of MNP@$SiO_2$ induced dose and time dependent cytotoxicity. At 6 h, 50, 100 or 200 nm MNP@$SiO_2$ decreased significantly cell viability over the concentration of 125 ${\mu}g/ml$ compared to vehicle control (p<0.05 or p<0.01). Moreover, at 24 h, 50 or 100 nm MNP@$SiO_2$ decreased significantly cell viability over the concentration of 125 ${\mu}g/ml$(p<0.01). And treatment of 200 nm MNP@$SiO_2$ decreased significantly cell viability at the concentration of 62.5 ${\mu}g/ml$ (p<0.05) and of 125, 250, 500 ${\mu}g/ml$ (p<0.01, respectively). Furthermore, at 48 h, 50, 100 or 200 nm MNP@$SiO_2$ decreased significantly cell viability at the concentration of 62.5 ${\mu}g/ml$ (p<0.05) and of 125, 250, 500 ${\mu}g/ml$ (p<0.01, respectively). Cellular location detected by confocal microscope represented they were existed in cytoplasm, mainly around cell membrane at 2 h after treatment of MNP@$SiO_2$. Treatment of 50 nm MNP@$SiO_2$ significantly increased DNA damage at middle and high dose (p<0.01), and treatment of 100 nm or 200 nm significantly increased DNA damage in all dose compared to control (p<0.01). Taken together, treatment of MNP@$SiO_2$ induced cytotoxicity and enhanced DNA damage in L5178Y cell.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

Structural and Microwave Dielectric Properties of $La(Mg_{1/2}Ti_{1/2})O_3$ Ceramics ($La(Mg_{1/2}Ti_{1/2})O_3$ 세라믹스의 구조 및 고주파 유전 특성 연구)

  • Yeo, Jae-Hyun;Baek, Jong-Hu;Nham, Sahn;Lee, Hwack-Joo;Park, Hyun-Min;Byun, Jae-Dong
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.943-947
    • /
    • 1999
  • The crystal structure and the microwave dielectric properties of $La(Mg_{1/2}Ti_{1/2})O_3$ ceramics have been investigated. $La(Mg_{1/2}Ti_{1/2})O_3$ has the 1:1 ordered monoclinic structure with the lattice parameters of $a = 5.5467(3){\AA}, b = 5.5616(3){\AA}, c = 7.8426(5) {\AA} and \beta = 89.9589 (2)^{\circ}$ The spacegroup of LMT is $P2_1/n$. Monoclinic LMT has the in­phase and anti-phase tilting of octahedra with the $a^_a^_c^_$ tilting system. Anti-parallel shift of A-site cations was also found in LMT. The relative density of the specimens sintered above $1600^{\circ}C$ was ranged between 95 % and 96 % of the theoretical density and the dielectric constant of specimens was about 28. The highest $Q\timesf$ achieved in this investigation was 63,100 for the specimen sintered at $1630^{\circ}C$ for 5 hr. Temperature coefficient of resonance frequency ranged from $>-74 ppm/^{\circ}C ~ -79 ppm/^{\circ}C$.

  • PDF

Speech Evaluation Tasks Related to Subthalamic Nucleus Deep Brain Stimulation in Idiopathic Parkinson's Disease: A Review (특발성 파킨슨병의 시상밑부핵 심부뇌자극술 관련 말 평가 과제에 대한 문헌연구)

  • Kim, Sun Woo;Kim, Hyang Hee
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.237-255
    • /
    • 2014
  • Idiopathic Parkinson disease(IPD) is an neurodegenerative disease caused by the loss of dopamine cells in the substantia nigra, a region of midbrain. Its major symptoms are muscular rigidity, bradykinesia, resting tremor, and postural instability. An estimated 70~90% of patients with IPD also have hypokinetic dysarthria. Subthalamic nucleus deep brain stimulation (STN-DBS) has been reported to be successful in relieving the core motor symptoms of IPD in the advanced stages of the disease. However, data on the effects of STN-DBS on speech performance are inconsistent. A medline literature search was done to retrieve articles published from 1987 to 2012. The results were narrowed down to focus on speech performance under STN-DBS based perceptual, acoustic, and/or aerodynamic analyses. Among the 32 publications which dealt with speech performance after STN-DBS indicated improvement(42%), deterioration(29%), mixed results(26%), or no change(3%). The most favorite method was found to be based upon acoustic analysis by using a vowel prolongation and Unified Parkinson's Disease Rating Scale(UPDRS). For the purpose of verifying the effect of the STN-DBS, speech evaluation should be undertaken on all speech components such as articulation, resonance, phonation, respiration, and prosody by using a contextual speech task.

Personal Credit Evaluation System through Telephone Voice Analysis: By Support Vector Machine

  • Park, Hyungwoo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.63-72
    • /
    • 2018
  • The human voice is one of the easiest methods for the information transmission between human beings. The characteristics of voice can vary from person to person and include the speed of speech, the form and function of the vocal organ, the pitch tone, speech habits, and gender. The human voice is a key element of human communication. In the days of the Fourth Industrial Revolution, voices are also a major means of communication between humans and humans, between humans and machines, machines and machines. And for that reason, people are trying to communicate their intentions to others clearly. And in the process, it contains various additional information along with the linguistic information. The Information such as emotional status, health status, part of trust, presence of a lie, change due to drinking, etc. These linguistic and non-linguistic information can be used as a device for evaluating the individual's credit worthiness by appearing in various parameters through voice analysis. Especially, it can be obtained by analyzing the relationship between the characteristics of the fundamental frequency(basic tonality) of the vocal cords, and the characteristics of the resonance frequency of the vocal track.In the previous research, the necessity of various methods of credit evaluation and the characteristic change of the voice according to the change of credit status were studied. In this study, we propose a personal credit discriminator by machine learning through parameters extracted through voice.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI (동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가)

  • Lee, Gil-Jae;Lee, Hwun-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.103-113
    • /
    • 2022
  • In this paper, a combined 18F-FDG(fluorodeoxyglucose) and MNP(magnetic nanoparticles) contrast agent was synthesized using N-(p-maleimidophenyl) isocyanate as the crosslinker for use in simultaneous PET-MRI scans. PET-MRI images were acquired and evaluated before and after injection of the combined contrast imaging agent (18F-FDG labeled MNP) from a glioma stem cell mouse model. After setting the region of interest (ROI) on each acquired image, the area of the lesion was calculated by segmentation. As a result, the PET image was larger than the MRI. In particular, the simultaneous PET-MRI images showed accurate lesions along with the surrounding soft tissue. The mean and standard deviation values were higher in the MRI images alone than in the PET images or the simultaneous PET-MRI images, regardless of whether the contrast agent was injected. In addition, the simultaneous PET-MRI image values were higher than for the PET images. For PSNR experiments, the original image was PET Image using 18F-FDG, MRI using MNPs, and MRI without contrast medium, and the target image was simultaneous PET-MRI image using 18F-FDG labeled MNPs contrast medium. As a result, all of them appeared significantly, suggesting that the 18F-FDG labeled MNPs contrast medium is useful. Future research is needed to develop an agent that can simultaneously diagnose and treat through SPECT-MRI imaging research that can use various nuclides.

A Comparative Study of Survivor Outcomes between Preoperative Evaluation Using CT Alone and Combined CT and MRI in Patients with Pancreatic Ductal Adenocarcinoma (췌장선암 환자의 수술 전 CT 단독 평가와 추가적 MRI 평가에 따른 생존 결과 비교 분석)

  • Ji Eun Lee;Seong Hyun Kim;Soon Jin Lee;Seo-Youn Choi;Sunyoung Lee;Bo Ra Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.638-653
    • /
    • 2021
  • Purpose To compare the recurrence pattern, disease-free survival (DFS), and overall survival (OS) after curative surgery for pancreatic ductal adenocarcinoma (PDAC) in patients who underwent preoperative evaluation with CT alone or in combination with MRI, and to compare the prognosis according to the first recurrence site. Materials and Methods We retrospectively evaluated 152 patients who underwent R0 resection of PDAC. Preoperative CT or combined CT and MRI were performed for 103 and 49 patients, respectively. Two radiologists recorded the location and date of the first recurrence in consensus. The recurrence pattern, DFS, and OS were compared between the two groups. OS was analyzed according to the first recurrence site. Results In both groups, liver metastasis was the most common recurrence pattern. DFS (p = 0.247) or OS (p = 0.067) showed no significant difference between the two groups. OS according to the first recurrence site was the lowest for liver metastasis, followed by locoregional recurrence (p < 0.001). Conclusion There were no significant differences in the recurrence pattern, DFS, or OS between patients evaluated with preoperative CT alone or with CT and MRI after curative resection of PDAC. Liver metastasis was the most common tumor recurrence pattern with the lowest OS.

Diagnostic Performance Using a Combination of MRI Findings for Evaluating Cognitive Decline (인지기능 저하평가를 위한 MR 영상 소견 조합의 진단능)

  • Jin Young Byun;Min Kyoung Lee;So Lyung Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.184-196
    • /
    • 2024
  • Purpose We investigated potentially promising imaging findings and their combinations in the evaluation of cognitive decline. Materials and Methods This retrospective study included 138 patients with subjective cognitive impairments, who underwent brain MRI. We classified the same group of patients into Alzheimer's disease (AD) and non-AD groups, based on the neuropsychiatric evaluation. We analyzed imaging findings, including white matter hyperintensity (WMH) and cerebral microbleeds (CMBs), using the Kruskal-Wallis test for group comparison, and receiver operating characteristic (ROC) curve analysis for assessing the diagnostic performance of imaging findings. Results CMBs in the lobar or deep locations demonstrated higher prevalence in the patients with AD compared to those in the non-AD group. The presence of lobar CMBs combined with periventricular WMH (area under the ROC curve [AUC] = 0.702 [95% confidence interval: 0.599-0.806], p < 0.001) showed the highest performance in differentiation of AD from non-AD group. Conclusion Combinations of imaging findings can serve as useful additive diagnostic tools in the assessment of cognitive decline.

Studies on the Applications of PSL, TL and ESR Methods for The Detection of Irradiated Foods not Allowed to be Irradiated in Korea (광자극발광법, 열발광법 및 전자스핀공명법을 이용한 국내 방사선 조사 허용 외 식품에 대한 검지법 적용 연구)

  • Kim, Kyu-Heon;Choi, Eun-Jin;Chang, Ho-Won;Shin, Choon-Shik;Kim, Moon-Young;Hwang, Cho-Rong;Kim, Eun-Jeong;Jo, Tae-Yong;Park, Geon-Sang;Kang, Myung-Hee;Kim, Jae-I;Kim, Jin-Sook;Park, Sue-Nie;Seong, Rack-Seon;Jang, Young-Mi;Yoon, Hae-Sung;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.233-246
    • /
    • 2012
  • In this study, we investigated the applicability of the photostimulated luminescence(PSL), thermoluminescence(TL) and electron spin resonance(ESR) methods for various foods which are not allowed to be irradiated in Korea. All 15 foods including sesame, almond, peanut, cocoa powder etc. were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative(lower than 700). The photon counts irradiated(1 kGy) dried shrimp, roasted peanut and seasoned peanut showed positive(higher than 5,000) and the other samples were negative or intermediate(> 700 and < 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal(single-line) intensity of irradiated foods was higher than non-irradiated foods. In particular, the specific ESR signals of irradiation-induced crystalline sugar, cellulose and bone radical were detected in dried plum, raisin, dried cherry, mango(dried, frozen), rambutan, cocoa(powder), cinnamon, parsley, carrot, broccoli, dried arrow squid, dried pollack and dried shrimp. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods because TL method is not able to detect the irradiated foods rarely composed of minerals. ESR is also a difficult method to detect the changes of ESR signal patterns of food. It is concluded that TL analysis or ESR assay is suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.