• 제목/요약/키워드: resonance evaluation

검색결과 834건 처리시간 0.045초

$Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향 (THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT)

  • 강인호;김명주;임영준;김창회
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

임플란트 식립 후 초기 안정성의 변화 (Initial Changes of Implant Stability from Installation during Early Bone Healing)

  • 박찬진;김대곤;조리라
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.272-279
    • /
    • 2013
  • 골치유 기간 중 임플란트-골 계면에서 일정 수준 이상의 미세동요가 발생하게 되면 임플란트의 골유착이 방해받게 되므로 임플란트 식립 후 초기 골반응에 관해 임플란트 안정성은 하나의 지표가 된다. 본 연구의 목적은 임플란트 식립 후 전향적인 연구를 통해 초기 임플란트 안정성 변화를 추적하여 골치유 양상을 추론하고자 하였다. 총 26명의 환자에게 식립된 30개의 임플란트를 대상으로 하악골에 1회법으로 식립 직후 1주 간격으로 12주간 공진주파수분석을 시행하여 초기 안정성의 변화를 구하였으며 식립 직후와 1개월 간격으로 변연골 흡수 정도를 방사선학적 방법으로 측정하였다. 식립 직후와 각 치유기간 동안의 ISQ값 비교에서 식립 4주에서 6주사이에 골질에 따른 차이를 보였으나(P<0.05), 6주 이후에는 골질군 간에는 임플란트 안정성 변화에 차이가 없었다(P>0.05). 방사선학적 검사에서는 변연골의 차이가 관찰기간내에 유의하게 변화하지 않았다(P>0.05). 임플란트 식립 후 초기 골치유과정은 골흡수과정에 연속적인 과정으로 4주 이후 바람직한 골치유과정이 진행됨을 공진주파수분석으로 관찰할 수 있었다.

죽령 및 벌채시기에 따른 맹종죽재의 물리적ㆍ기계적 특성 (Physical and Mechanical Properties of Phyllostachys pubescens According to Growth Age or Felling Time)

  • 안상열;신훈재;변희섭;박상범;공영토
    • 임산에너지
    • /
    • 제22권1호
    • /
    • pp.8-16
    • /
    • 2003
  • 경남 진주시 가좌동에 위치한 남부임업시험장내의 생육이 양호한 1년산, 2년산, 3년산의 맹종죽을 이용하여 2001년 6월부터 다음해인 2002년 5월까지 실험을 실시하여 죽령과 벌채시기(달별)에 따른 물리적ㆍ기계적 성질에 대한 실험 결과는 다음과 같다. 생장부위에 따라서는 상부위에서 밀도, MOEs, MOE/sub d/의 값이 가장 높게 나타났으며, 또한 전체 밀도와 3년생의 MOEs와 MOE/sub d/는 벌채시기가 늦어질수록 점차적으로 그 값이 증가하였다. 그러나 함수율과 1, 2년산의 맹종죽재에서는 뚜렷한 차이점을 보이지 않아 죽령과 벌채시기에 따라서는 아무런 경향을 나타내지 않았다. MOEs와 MOE/sub d/의 상관관계에 있어서 r값은 생재가 0.88, 기건재가 0.92로 나타났으며, MOE/sub d/가 MOEs의 값보다 생재가 18.5%, 기건재가 7%정도 높게 나타났다. 또한 죽령과 벌채시기에 따른 MOEs와 MOE/sub d/가 거의 동일한 경향으로 매우 잘 대응하여 맹종죽재의 탄성적 성질을 평가하는데 있어서 공진주파수를 이용한 비파괴 측정법이 일반 소재와 마찬가지로 맹종죽재의 경우에도 이용 가능하였다.

  • PDF

Susceptibility Vessel Sign for the Detection of Hyperacute MCA Occlusion: Evaluation with Susceptibility-weighted MR Imaging

  • Lee, Sangmin;Cho, Soo Bueum;Choi, Dae Seob;Park, Sung Eun;Shin, Hwa Seon;Baek, Hye Jin;Choi, Ho Cheol;Kim, Ji-Eun;Choi, Hye Young;Park, Mi Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.105-113
    • /
    • 2016
  • Purpose: Susceptibility vessel sign (SVS) on gradient echo image, which is caused by MR signal loss due to arterial thrombosis, has been reported in acute middle cerebral artery (MCA) infarction. However, the reported sensitivity and diagnostic accuracy of SVS have been variable. Susceptibility-weighted imaging (SWI) is a newly developed MR sequence. Recent studies have found that SWI may be useful in the field of cerebrovascular diseases, especially for detecting the presence of prominent veins, microbleeds and the SVS. The purpose of this study was to evaluate the diagnostic values of SWI for the detection of hyperacute MCA occlusion. Materials and Methods: Sixty-nine patients (37 males, 32 females; 46-89 years old [mean, 69.1]) with acute stroke involving the MCA territory underwent MR imaging within 6 hours after the symptom onset. MR examination included T2, FLAIR (fluid-attenuated inversion recovery), DWI, SWI, PWI (perfusion-weighted imaging), contrast-enhanced MR angiography (MRA) and contrast-enhanced T1. Of these patients, 28 patients also underwent digital subtraction angiography (DSA) within 2 hours after MR examination. Presence or absence of SVS on SWI was assessed without knowledge of clinical, DSA and other MR imaging findings. Results: On MRA or DSA, 34 patients (49.3%) showed MCA occlusion. Of these patients, SVS was detected in 30 (88.2%) on SWI. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of SWI were 88.2%, 97.1%, 96.8%, 89.5% and 92.8%, respectively. Conclusion: SWI was sensitive, specific and accurate for the detection of hyperacute MCA occlusion.

동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가 (A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects)

  • 김재창;경성현;이종두;박해정
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권3호
    • /
    • pp.169-180
    • /
    • 2013
  • 목적 : 본 연구는 신경망의 인과성을 이해하기 위해 사용되는 방법인 뇌경두개자기자극기 (TMS)를 기능자기공명영상(fMRI) 내에서 동시에 시행하기 위한 적합성을 평가하는데 그 목적이 있다. 대상 및 방법 : TMS 코일을 지지할 수 있도록 비자성의 특징을 갖는 물질인 Polyetherether Keton (PEEK)을 이용하여 홀더를 제작하였다. 컴퓨터 시뮬레이션을 이용하여 MR 스캐너 안에서의 TMS 코일의 위치와 방향에 따른 자기장의 분포를 계산하였다. 또한, TMS 자극시 발생할 수 있는 영상 왜곡을 최소화하면서 fMRI영상을 획득하기 위하여 볼륨과 볼륨 획득 사이 간극 동안 TMS 자극을 가하는 기법을 제안하였다. 결과 : 컴퓨터 시뮬레이션을 통해서 코일 중심의 자기장은 코일에서 거리가 멀어질수록 급격하게 감소함을 확인하였다. 팬텀실험을 통해 fMRI 자극제시는 볼륨간 시간 간격을 100 ms정도 수준에서도 영상 왜곡을 줄이는데 문제가 없음을 확인하였다. 운동 과제 수행과 TMS로 운동 중추 자극시 각각의 뇌반응 분석 연구를 통해 fMRI 측정 중 TMS가 가능함을 확인하였다. 결론 : 본 연구를 통해 fMRI 환경 내에서 관심 영역에 TMS를 가함으로써 뇌 기능의 인과적 연결성 연구를 할 수 있는 기본 도구를 확립하게 되었다.

Comparison of 3D Volumetric Subtraction Technique and 2D Dynamic Contrast Enhancement Technique in the Evaluation of Contrast Enhancement for Diagnosing Cushing's Disease

  • Park, Yae Won;Kim, Ha Yan;Lee, Ho-Joon;Kim, Se Hoon;Kim, Sun-Ho;Ahn, Sung Soo;Kim, Jinna;Lee, Seung-Koo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.102-109
    • /
    • 2018
  • Purpose: The purpose of this study is to compare the performance of the T1 3D subtraction technique and the conventional 2D dynamic contrast enhancement (DCE) technique in diagnosing Cushing's disease. Materials and Methods: Twelve patients with clinically and biochemically proven Cushing's disease were included in the study. In addition, 23 patients with a Rathke's cleft cyst (RCC) diagnosed on an MRI with normal pituitary hormone levels were included as a control, to prevent non-blinded positive results. Postcontrast T1 3D fast spin echo (FSE) images were acquired after DCE images in 3T MRI and image subtraction of pre- and postcontrast T1 3D FSE images were performed. Inter-observer agreement, interpretation time, multiobserver receiver operating characteristic (ROC), and net benefit analyses were performed to compare 2D DCE and T1 3D subtraction techniques. Results: Inter-observer agreement for a visual scale of contrast enhancement was poor in DCE (${\kappa}=0.57$) and good in T1 3D subtraction images (${\kappa}=0.75$). The time taken for determining contrast-enhancement in pituitary lesions was significantly shorter in the T1 3D subtraction images compared to the DCE sequence (P < 0.05). ROC values demonstrated increased reader confidence range with T1 3D subtraction images (95% confidence interval [CI]: 0.94-1.00) compared with DCE (95% CI: 0.70-0.92) (P < 0.01). The net benefit effect of T1 3D subtraction images over DCE was 0.34 (95% CI: 0.12-0.56). For Cushing's disease, both reviewers misclassified one case as a nonenhancing lesion on the DCE images, while no cases were misclassified on T1 3D subtraction images. Conclusion: The T1 3D subtraction technique shows superior performance for determining the presence of enhancement on pituitary lesions compared with conventional DCE techniques, which may aid in diagnosing Cushing's disease.

감마선 조사된 분말수프의 이화학적 품질과 조사여부 판별특성 (Physicochemical Quality and Detection Properties of Irradiated Powdered-Soups)

  • 곽지영;안영은;정보윤;권중호
    • Current Research on Agriculture and Life Sciences
    • /
    • 제30권2호
    • /
    • pp.82-89
    • /
    • 2012
  • 시판 다소비 분말수프 3종(감자 수프/PS, 옥수수 수프/CS, 향신료 수프/CHS)에 대한 살균 목적의 감마선 조사(0, 1, 5, 10 kGy)가 이화학적 품질에 미치는 영향을 평가하였다. 아울러 감마선 조사 여부의 판별을 위하여 광자극발광분석(PSL), 전자스핀공명분석(ESR) 및 열발광분석(TL)의 적용가능성을 확인하였다. 시료의 수분함량 및 pH는 조사 여부에 상관없이 비교적 안정적이었으나, 기계적 색도는 조사선량이 증가할수록 PS 시료의 명도(L)는 감소하였고 황색도(b)는 증가하였다. 수프현탁액의 점도는 감마선 조사에 따라 크게 감소하였으며, PS>CS>CHS의 순으로 점도의 감소가 크게 나타났다. 분말수프의 감마선 조사 여부 판별시험에서 1 kGy 이상의 조사시료는 PSL 측정에서 5000 PCs 이상의 값을, ESR 측정에서 crystalline sugar 유래의 multicomponents signal을, 그리고 TL 측정에서 typical TL glow curve를 각각 나타내어 PSL, ESR 및 TL 분석의 적용가능성이 확인되었다.

  • PDF

직구동 전기기계식 구동기의 강성요구규격에 기반한 설계용 해석모델 (Analysis Model for Design Based on Stiffness Requirement of Direct Drive Electromechanical Actuator)

  • 오상관;이희중;박현종;오동호
    • 한국항공우주학회지
    • /
    • 제47권10호
    • /
    • pp.738-746
    • /
    • 2019
  • 한국형발사체 3단에 사용되는 7톤 짐벌엔진의 추력벡터제어에는 전기유압식 구동장치시스템 대신 중량, 비용 및 시험평가 등의 측면에서 더 효율적인 전기기계식 구동장치시스템을 사용한다. 전기기계식 구동기는 위치제어 서보 구동기로 고진공에서도 운용 가능한 BLDC 모터를 사용한다. 짐벌엔진을 갖는 발사체의 경우 구동기 자체 진동모드와 구동기를 지지하는 기체구조체의 벤딩모드, 짐벌엔진의 관성부하 등이 조합되어 합성공진 현상이 발생할 수 있다. 합성공진이 발생할 경우 발사체 자세제어는 불안정해진다. 이러한 관계로 짐벌엔진 및 기체구조체 지지부, 구동장치시스템의 고유 특성을 고려하여 강성에 대한 요구규격이 적용되어 왔다. 한국형발사체 3단 7톤 짐벌엔진의 경우 구동장치시스템의 강성요구규격은 $3.94{\times}10^7N/m$ 수준이며 이를 만족시키기 위한 직구동 방식전기기계식 구동기를 설계하였다. 본 논문에서는 강성요구규격을 기반으로 설계된 직구동 전기기계식 구동기의 등가강성 해석모델을 제안하고, 이를 실험결과로 검증하였다.

백질변성이 섬망의 심각도 및 경과에 미치는 영향 (The Effect of Leukoaraiosis on the Severity and Course of Delirium)

  • 최원정;석정호;오승택;정태섭;김재진
    • 정신신체의학
    • /
    • 제26권2호
    • /
    • pp.194-200
    • /
    • 2018
  • 연구목적 뇌 자기공명영상에서 발견된 백질변성의 소견은 인지기능 저하와 관련이 있다고 알려져 있지만 이의 중요성은 명확하게 밝혀진 바 없다. 본 연구는 뇌 자기공명영상에서 관찰되는 백질변성이 섬망의 심각도나 경과에 미치는 영향을 규명하기 위해 시행되었다. 방 법 섬망 삽화 전후에 뇌 자기공명영상이 촬영된 42명의 섬망 환자에 대하여 반정량적인 시각평가척도를 이용하여 뇌실주위 백질 고강도신호와 심부백질 고강도신호를 평가하였다. 이 고강도신호의 등급과 섬망평가척도 점수 간의 상관 관계를 분석하였고, 등급이 높은 군과 낮은 군으로 나누어 군에 따른 섬망평가척도 점수의 변화 차이를 추가로 분석하였다. 결 과 후두엽의 심부백질 고강도신호 등급과 섬망평가척도의 총점, 심각도 항목, 인지 항목 및 비인지 항목의 합과 양의 상관관계를 보였다. 또한 첫 평가와 추적 평가를 비교하였을 때 뇌실주위 백질 고강도신호의 등급이 낮은 군이 높은 군보다 섬망평가척도의 인지 항목 점수가 유의미한 경사로 가파르게 감소하였다. 결 론 뇌 백질 고강도신호 등급에 따라 섬망의 심각도와 호전 속도에 차이를 보이는 것은 뇌 백질변성이 대뇌 기능 연결성의 단절을 초래하여 유발한 결과로 볼 수 있다. 본 연구는 뇌 자기공명영상에서 발견된 고강도신호의 등급의 평가를 통해 섬망의 심각도와 경과를 예측해 볼 가능성이 있다는 점에서 임상적으로 유용할 수 있다.

Comparison of Magnetic Resonance Imaging and Operation Waiting Times in Patients Having Traumatic Cervical Spinal Cord Injury; with or without Bony Lesions

  • Heo, Jeong;Min, Woo-Kie;Oh, Chang-Wug;Kim, Joon-Woo;Park, Kyeong-hyeon;Seo, Il;Park, Eung-Kyoo
    • Journal of Trauma and Injury
    • /
    • 제32권2호
    • /
    • pp.80-85
    • /
    • 2019
  • Purpose: To compare the time intervals to magnetic resonance imaging (MRI) and surgical treatment in patients having traumatic cervical spinal cord injury (SCI) with and without bony lesions. Methods: Retrospectively analyzed adult patients visited Kyungpook National University Hospital and underwent surgical treatment for cervical SCI within 24 hours. The patients who were suspected of having cervical SCI underwent plain radiography and computed tomography (CT) upon arrival. After the initial evaluation, we evaluated the MRI findings to determine surgical treatment. Waiting times for MRI and surgery were evaluated. Results: Thirty-four patients were included. Patients' mean age was 57 (range, 23-80) years. Patients with definite bony lesions were classified into group A, and 10 cases were identified (fracture-dislocation, seven; fracture alone, three). Patients without bony lesions were classified into group B, and 24 cases were identified (ossification of the posterior longitudinal ligament, 16; cervical spondylotic myelopathy, eight). Mean intervals between emergency room arrival and start of MRI were 93.60 (${\pm}60.08$) minutes in group A and 313.75 (${\pm}264.89$) minutes in group B, and the interval was significantly shorter in group A than in group B (p=0.01). The mean times to surgery were 248.4 (${\pm}76.03$) minutes in group A and 560.5 (${\pm}372.56$) minutes in group B, and the difference was statistically significant (p=0.001). The American Spinal Injury Association scale at the time of arrival showed that group A had a relatively severe neurologic deficit compared with group B (p=0.046). There was no statistical significance, but it seems to be good neurological recovery, if we start treatment sooner among patients treated within 24 hours (p=0.198). Conclusions: If fracture or dislocation is detected by CT, cervical SCI can be easily predicted resulting in MRI and surgical treatment being performed more rapidly. Additionally, fracture or dislocation tends to cause more severe neurological damage, so it is assumed that rapid diagnosis and treatment are possible.