• Title/Summary/Keyword: resisting force

Search Result 259, Processing Time 0.021 seconds

Case Study on the Characteristics of Vertical Bearing Capacity for Steel Pipe Pile Installed by PRD (PRD 강환 말뚝의 연직지지력 특성에 관한 사례 연구)

  • 최용규;정창규;정성기;김동철;정태만
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.225-232
    • /
    • 1999
  • Construction case of PRD (Percussion Rotary Drill) pipe pile and matters to be attended in construction of PRD pile were reviewed. The compressive and uplifting static pile load tests for PRD piles were performed and, also, analysis by Pile Driving Analyzer was done. Based on these results, bearing components in each resisting part (that is: steel toe, external skin, and internal skin) were measured separately. The measured resisting force was compared to the value calculated by the estimated formula. The pile capacity was mobilized in steel toe area and the external skin friction and the internal friction were not produced. Thus, it could be considered that toe of PRD pile should be supported in hard bearing stratum (for example, the fresh soft rock).

  • PDF

Evaluation of the Influence of Alignment Error in the Sharpness Test of a Micro-Needle (세침의 예리도 시험에서의 정렬 오차 영향 평가)

  • Lee J. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.250-253
    • /
    • 2004
  • Sharpness of the tip of micro needle is very Important quality that should be controlled in the manufacturing processes. Acupuncture needle is one of the most widely used micro-needle. And the tip sharpness of acupuncture needle Is usually checked by the magnitude of resisting force obtained through sharpness test. In this study, some sharpness tests of acupuncture needle were done and the relationship between the misalignment of specimen and the magnitude of resisting force. The diameter of the needle used in the test was $250\;{\mu}m$ and the length of it was 40 mm.

  • PDF

A Study of Micro-piles Method combined with the Resisting Fixture interacting the power of frictional resistance in a contrary direction (양방향 저항체를 결합한 마이크로파일공법 연구)

  • Baik, Dong-Ho;Lee, Sang-Moo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.74-75
    • /
    • 2014
  • In remodeling business or construction of both new strucures and existing structures, Case that pile foundation was set is often. Micro pile, holding compressive force and tensile force by spherical friction, is supported by skin friction rather than end bearing capacity. but, This is weak in tension. Active area of micro pile's skin friction is narrow and micro pile don't do unification behavior hence. So bearing capacity was not fully mobilized in existing researching. In this study, in order to compensate for this method, micro pile to install Resisting Fixture is proposed.

  • PDF

A Study on the Bond Properties of Carbon Fiber Sheets used for Strengthening Structures (구조물 보강용 탄소섬유쉬트의 부착특성에 관한 연구)

  • 황진석;김지영;백명종;박형철;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.653-658
    • /
    • 1997
  • Recently, carbon Fiber sheet (CFS) is frequently used for strengthening deteriorated concrete structures. To strengthening damaged structures, the property and characteristic of the bond between CFS and the concrete surface must be understood. The tensile test of single lap shear specimen was performed to study bond strength, bond stress distribution and stress transfer between CFS and concrete surface according to the bond length. Based on the test results, there were ultimate influence length (UIL) in which bond stress was distributed, and ultimate strain reduction ratio (USRR) by which strain was reduced linearly. Bond resisting force (BRF) was estimated by UIL and USRR, and which was compared with ultimate loads. According to the results of comparison, it was shown that ultimate bond strength could be estimated reasonablely by BRF.

  • PDF

Strengthening method using externally-bonded steel frames for promoting the seismic performance of existing buildings (기존 건축물 내진성능 향상을 위한 철골 골조 외부부착 보강공법)

  • Mauk, Ji-Wook;Park, Young-Mi;Park, Ki-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.98-99
    • /
    • 2018
  • Seismic retrofitting technologies have been paid attention to structural engineers for rehabilitations of existing building structures vulnerable to seismic loading conditions. This paper introduces the traditional strengtheing method applying externally-bonded steel frames to column and beam elements, and compares with the improved scheme using the frames with additional energy dissipation systems. Throughout experimental studies, it was observed that the method can be effective for promoting the seismic performance of seismic force-resisting systems by guaranteeing strong column-weak beam mechanism. Compared to the traditional manner, it was found that the new scheme can be more efficient for confirming capacity design concept, while energy dissipation systems can provide additional damping effects corresponding to lateral deformation which occurs at seismic force-resisting systems exposed to seismic excitations.

  • PDF

Application of a ductile connection system to steel MRF strengthened with hinged walls

  • Zhi Zhang;Yulong Feng;Dichuan Zhang;Zuanfeng Pan
    • Steel and Composite Structures
    • /
    • v.51 no.5
    • /
    • pp.487-498
    • /
    • 2024
  • Steel moment resisting frames (MRFs) typically have inter-story drift concentrations at lower stories during earthquakes as found from previous research. Hinged walls (HWs) can be used as structural strengthening components to force the MRFs deform uniformly along the building height. However, large moment demands are often observed on HWs and make the design of HWs non-economical. This paper proposes a method to reduce the moment demand on HWs using a ductile connection system between the MRFs and the HWs. The ductile connection system is designed with a yield strength and energy dissipation capacity, for the purpose of limiting the seismic forces transferred to the HWs and dissipating seismic energy. Nonlinear time history analyses were performed using 10 far-filed earthquakes at maximum considered earthquake level. The analysis results show that the proposed ductile connection system can reduce: (1) seismic moment demands in the HWs; (2) floor accelerations; (3) the connection force between HWs and MRFs.

Analysis on Phase Relation between Inertia Force and Dynamic Earth Pressure of Caisson by Numerical Analysis (수치해석을 이용한 우물통 기초의 관성력과 동적토압의 위상관계 분석)

  • Kim, Sung-Ryul;Jang, Hak-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Dynamic earth pressure acting on geotechnical structures can be driving force or resisting force for the displacement of the structure according to the phase relation between the dynamic earth pressure and inertia force of structures. In this research, the evaluation procedure of the phase relation between the dynamic earth pressure and the inertia force was proposed. According to the procedure, numerical analyses on caisson foundation of bridges were performed and the phase relation was analyzed. The analysis results showed that the dynamic earth pressure becomes the driving force, which increases the displacement of the structure, if the displacement amplitude of ground is larger than that of structure due to the low stiffness of the ground, and the dynamic earth pressure becomes the resisting force against the displacement of the structure if the displacement amplitude of ground is smaller than that of structure due to the high stiffness of the ground.

Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections (포스트 텐션 플랫 플레이트 슬래브 접합부의 거동)

  • Cho Kyung Hyun;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF

Assessment of Post-Earthquake Fire Behavior of a Steel MRF Building in a Low Seismic Region

  • Chicchi, Rachel;Varma, Amit
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1470-1481
    • /
    • 2018
  • Building-level response to post-earthquake fire hazards in steel buildings has been assessed using primarily two-dimensional analyses of the lateral force resisting system. This approach may not adequately consider potential vulnerabilities in the gravity framing system. For this reason, three-dimensional (3D) finite element models of a 10-story case study building with perimeter moment resisting frames were developed to analyze post-earthquake fire events and better understand building response. Earthquakes are simulated using ground motion time histories, while Eurocode parametric time-temperature curves are used to represent compartment fires. Incremental dynamic analysis and incremental fire analysis procedures capture a range of hazard intensities. Findings show that the structural response due to earthquake and fire hazards are somewhat decoupled from one another. Regardless of the level of plastic hinging present in the moment framing system due to a seismic event, gravity column failure is the initiating failure mode in a fire event.