• Title/Summary/Keyword: resistance rate

Search Result 3,539, Processing Time 0.032 seconds

Analysis of Factors Rerated to Absorption Ability of Foliage Plants Exposed to $O_3$ (관엽식물의 오존($O_3$)흡수능에 관여하는 요인 분석)

  • 박소홍;배공영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.537-544
    • /
    • 1998
  • We selected Spathiyhyllum patinii and Pachira aqkatica, since the former has high O3 absorption while the latter low absorption, and analyzed physiological factors such as diffusive coefficient, transpiration rate, photosynthetic rate, and CO2 absorption rate, which affected O3 absorption capacity There was significant relationship between gas absorption capacity and the other factors; photosynthetic rate, diffusive resistance, stomatal resistance and CO2 absorption rate. Therefore model formula for estimation of O3 absorption rate in plant was formulated by making use of these factors. There was difference for the estimation of O3 absorption rate according to plant species. In case of Spathiphyllum patinii, photosynthetic rate is an optimal factor for estimation of O3 absorption capacity. On the other hand, stomatal resistance and diffusive resistance are optimal factors of Pachira aquatica among various physiological ones. And we knew that CO2 absorption rate is a potential factor to evaluate gas absorption capacity regardless of plant species. But considering efficiency and practicality, diffusive resistance was the most effective factor for the estimation of O3 gas absorption.

  • PDF

Study on an On-line Measurement System of Corrosion Rate by Linear Polarization Resistance (분극저항에 의한 온라인 부식속도 측정 시스템에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun;Lee, Jae Bong;Park, Pyl Yang
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.135-140
    • /
    • 2012
  • The linear polarization resistance method is one of the widely used techniques for the corrosion rate monitoring in the water circulating systems of plants. The measurement is simple and rapid, so that a continuous on-line monitoring is possible without any shutdown of plants. A 2-electrode polarization corrosion rate measurement system was installed in a laboratory using a data acquisition board and PC. The signal processing parameters were optimized for the accurate corrosion rate measurement, and the polarization resistance was compensated with the solution resistance measured by the high frequency sine wave signal of an output channel. The precision of corrosion rate data was greatly improved by removing the initial noise signals on measuring the polarization resistance.

Effect of Strain Rate on the Deformation and Cracking Behaviors of ITO/PET Sheets with 45 ohms/sq. Sheet Resistance (면저항 45 ohms/sq.의 ITO/PET Sheets의 변형률 속도에 따른 균열 형성 거동)

  • Kim, Jin-Yeol;Hong, Sun-Ig
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2009
  • The stress-strain behavior and its effects on the crack initiation and growth of ITO film on PET substrate with a sheet resistance of 45 ohms/sq were investigated. Electrical resistance increased gradually at the strain of 0.7% in the elastic to plastic transition region of the stress strain curves. Numerous cracks were observed after 1% strain and the increase of the resistance can be linked to the cracking of ITO thin films. The onset strain for the increase of resistance increased with increasing strain rate, suggesting the crack initiation is dependent on the strain rate. Upon loading, the initial cracks perpendicular to the tensile axis were observed and propagated the whole sample width with increasing strain. The spacing between horizontal cracks is thought to be determined by the fracture strength and the interfacial strength between ITO and PET. The crack density increased with increasing strain. The spacing between horizontal cracks (perpendicular to the stress axis) increased with decreasing strain rate, The increase of crack density with decreasing strain rate can be attributed to the higher fraction of the plastic strain to the total strain at a given total strain. As the strain increased over 5% strain, cracks parallel to the stress axis were developed and increased in number with strain, accompanied by drastic increases of resistance.

Antibiotic Resistance in Staphylococcus aureus Isolated in Busan (부산에서 분리된 황색포도상구균의 항생제 내성 양상)

  • Lee, Jae-Yoon;Park, Jung-Hee;Moon, Kyung-Ho
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.164-168
    • /
    • 2007
  • Antibiotic resistance patterns of 21 antibiotics were studied for 50 strains of Staphylococcus aureus isolated from a hospital in Busan from July 2005 to December 2006. All strains showed antibiotic resistance to more than one antibiotic and 3 strains showed resistance to 17 different antibiotics. The strains isolated between 2005 and 2006 had lower resistance rate to 12 antibiotics (other than vancomycin and ampicilin) than the strains isolated between 1989 and 1990. In particular, no chlorarmphenicol resistant strain was found in this study which is contrasted with 34.8% resistant rate obtained in the study conducted between 1989 and 1990. In respect of vancomycin, no resistant strain was found in this study which is the same result obtained in the 1989 to 1990 study; All strains investigated in this study showed 100% resistance rate to ampicillin compared to 69.6% in the previous study.

Clinical Study of Prevalence of Antibiotic Resistance of Escherichia coli in Urinary Tract Infection in Children: A 9-year Retrospective, Single Center Experience

  • Seo, Eun Young;Cho, Seung Man;Lee, Dong Seok;Choi, Sung Min;Kim, Doo Kwun
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.121-127
    • /
    • 2017
  • Purpose: The aim of this study was to determine the prevalence of antibiotic susceptibility and resistance of Escherichia coli in urinary tract infections (UTIs) in children. Methods: We retrospectively reviewed the clinical records of 212 inpatients aged 18 years or younger with UTIs treated at the Pediatric Department of Dongguk University Gyeongju Hospital between January 2008 and December 2016. For comparison, patients were divided into three groups according to age as follows: group 1, ${\leq}1$ month; group 2, >1 month to ${\leq}12$ months; and group 3, ${\geq}13$ months. The antibiotic resistance rates from January 2008 to December 2012 (study period 1) and from January 2013 to December 2016 (study period 2) were analyzed statistically by group. Results: As the patient age increased, the antibiotic resistance rate to ampicillin (P=0.013), levofloxacin (P=0.050), piperacillin/tazobactam (TZP) (P<0.001), and trimethoprim/sulfamethoxazole (P=0.002) increased. The frequency of extended spectrum beta-lactamase producing E. coli showed a significant difference from 5 cases (4.6%) in study period 1 and 16 cases (15.8%) in study period 2 (P=0.007). The antibiotic resistance rate of E. coli was compared between the two time periods and we found that the antibiotic resistance rate to cefotaxime was significantly increased from 5.4% to 16.8% (P=0.008) and that to TZP was significantly decreased from 40.5% to 7.9% (P<0.001). Conclusion: Over the past 9 years, the resistance rate to cefotaxime has increased but the resistance rate to TZP has decreased. Thus, it is important to continue to investigate the antibiotic resistance rates of bacteria in the community.

Si(100)에 이온 주입 시 dose rate에 따른 damage profile과 sheet resistance의 변화

  • Kim, Hyeong-In;Jeong, Yeong-Wan;Gang, Seok-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.188-188
    • /
    • 2010
  • 동일한 에너지와 일정한 dose량을 유지하고 dose rate만을 변화시켜가며 이온을 Si(100) 표면에 주입하였다. 이러한 조건하에서 이온의 dose rate가 커지게 되면 시료 내에서 relaxation되는 시간이 짧아져서 damage의 양이 증가하게 되고 depth profile의 꼬리부분이 표면 쪽으로 올라오게 된다. 이와 같은 damage profile의 변화가 sheet resistance에 영향을 준다는 실험결과가 있다. 본 연구에서는 Crystal-TRIM computer simulation을 통해서 depth profile과 damage profile의 결과를 얻고, dose rate가 커질수록 시료표면 근방에 잔류 damage의 양이 높게 나타나는 것을 확인할 수 있다. 또한, 잔류 damage의 표면근방에서의 분포가 annealing 이후 sheet resistance를 변화시키는데 이에 대한 mechanism을 규명하고자 한다.

  • PDF

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

Microstructural Characteristics of Zircaloy-4 Nuclear Fuel Cladding Welds by Resistance Upset Welding Processes (저항 업셋 용접방식에 따른 Zircaloy-4 핵연료 피복재 용접부의 미세조직 특성)

  • 고진현;김상호;박춘호;김수성
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.98-104
    • /
    • 2002
  • A study on microstructures of welds for Zircaloy-4 sheath end closure by the resistance upset welding methods was carried out. Two upset welding process variations such as magnetic farce and multi-impulse resistance welding were used. Grain size and microhardness across welds were analysed in terms of welding parameters. Magnetic farce resistance weld with one cycle of unbalanced mode has smaller upset length and $\alpha-grain$ size in heat affected zone than those of multi-impulse resistance weld because of lower heat input and shorter welding time. Heat affected zone formed by two upset resistance welding variations revealed fine Widmanstatten structure or martensitic ${\alpha}'$ structure due to the high heating rate and foster cooling rate. Magnetic force resistance welds showed recrystallized grains before grain growth, whereas multi-impulse resistance welds showed full grain growth.

The resistance rate of anti-tuberculosis drug isolated from initial tuberculosis patients at a general hospital in Daejeon area (대전지역 일개 종합병원 초진결핵 환자들로부터 분리(分離)된 결핵균(結核菌)의 약제(藥劑) 내성률(耐性率))

  • Lee, Dong-Hoon;Kim, Sang-Ha;Kim, Young-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5012-5018
    • /
    • 2011
  • According to the nationwide survey of tuberculosis from 1965 to 1995, the incidence and drug resistance rate of tuberculosis have been decreased in Korea, but the prevalence of multidrug resistance of Mycobacterium tuberculosis is still a serious problem. The purpose of this study is to investigate the drug resistance rate and pattern of tuberculosis in Daejeon from 2001 to 2008. Of the total 581cases where the drug susceptibility test was performed, resistance to at least one anti-TB drug was found in 104 cases(17.9%) of these, 68(11.7%) were resistant to at least INH and 41(7.1%) were resistant to at least RFP. Single-drug resistance was found for isolates from 37(6.4%) ; 18(3.1%) of these were resistant to INH and 5(0.9%) to RFP. Multidrug resistance, where TB was resistant to at least isoniazid and refampin, was found in 35 cases(6.0%). and Factors associated with MDR-TB included age under 40-60.The drug-resistance rate of pulmonary TB, especially MDR-TB, is higher in the initial treated patients at a private referral hospital than in those in the pubulic sector. Initial drug resistance is common and the drug susceptibility test is informative for pulmonary TB patients who have not received previous TB treatment. The need for an improved control program, coupled with early diagnosis of MDR-TB, to reduce the spread and development of resistance. Multidrug resistance rate is still problem in korea. Efforts to decrease multidrug resistance rate either independently or in cooperation with the pubulic sector will be needed.

Study on Characteristics of Corrosion Fatigue Crack Growh Rate of SUS 304 Stainlss Steel (SUS 304강의 부식피로균열 운전속도 특성에 관한 연구)

  • 임우조;김부안
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.93-100
    • /
    • 1987
  • Corrosion fatigue cracking of the austenitic stainless steel(bese metal & heat affected zone by TIG weld) was studied experimentally under the environments of various specific resistance and air. The characteristics of corrosion fatigue crack growth rate and the environmental constants of paris' rule were investigated for SUS 304 weldments in the various specific resistance. The influences of stress intensity factor range and corrosion on the crack growth rate were compared. The characteristics of corrosion fatigue cracking for the weldments were inspected from mechanical, electrochemical and microstructural point of view. Main results obtained are as follows: 1) As the specific resistance decreases, the environmental constant C of paris'rule increases(hence the corrosion fatigue crack growth rate is rapid), but the environmental constant m decreases, so the effect of corrosion to the crack growth rate is more susceptible than thet of stress intensity factor range. 2) As the stress intensity factor range decreases, the corrosion fatigue crack growth rate of heat affected zone is more susceptible than that of the base metal. 3) The corrosion fatigue crack growth rate of the heat affected zone is more rapid than that of the base metal, because of the phenomenon of softening and the less noble potential coused by wedlding heat cycle. 4) The corrosion fatigue cracking of SUS 304 weldment appears transgranular fracture.

  • PDF