• 제목/요약/키워드: resistance of load

검색결과 2,437건 처리시간 0.024초

(PbCaSr)(TiMnSb)$O_3$ 세라믹스를 이용한 두께진동모드 적층 압전 변압기의 전기적 특성 (The Electrical Properties of Thickness Vibration Mode Multilayer Piezoelectric Transformer using (PbCaSr)(TiMnSb)$O_3$ Ceramics)

  • 유경진;류주현;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.196-197
    • /
    • 2006
  • In this study, low temperature sintering multilayer piezoelectric transformer for DC-DC converter were manufactured using (PbCaSr)Ti(MnSb)$O_3$ ceramics and thin their electrical properties were investigated according to the vanation of frequency and load resistance. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum value m the vicinity of 1.3MHz and increased according to the increase of load resistance. When the output impedance coincided with the load resistance, the piezoelectric transformer showed the temperature rise of about $21^{\circ}C$ under the output power of 6W.

  • PDF

디스크형 압전변압기의 전극비에 따른 전기적 특성 (Electrical Characteristics of Disk-type Piezotransformer with Electrode Ratio of Driving and Generating Part)

  • 이종필;채홍인;정수현;강형식;이충호;신현택;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1490-1492
    • /
    • 2003
  • A new type of piezoelectric transformer using radial vibration of disk, poled with the same direction is proposed. The piezoelectric ceramics was composed to PZT-PMN-PSN. The surface ratio of driving electrode and generating electrode of the piezoelectric transformer ranges from 1.4:1 to 3:1. As a experimental result, both resonance frequency and step-up voltage ratio increased with increasing load resistance. The step-up voltage ratio was reached more than 60 times under no load resistance. The maximum efficiency of 97.7% at load resistance of 2k${\Omega}$ was obtained.

  • PDF

척추고정장치의 피로성능 평가와 향상 (Enhancement and Evaluation of Fatigue Resistance for Spine Fixation System)

  • 김현묵;김성곤
    • 한국정밀공학회지
    • /
    • 제26권8호
    • /
    • pp.142-147
    • /
    • 2009
  • Spinal fixation systems provide surgical versatility, but the complexity of their design reduces their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. A group of two assemblies was tested in static compression. One group was applied to surface a grit blasting method and another group was applied to surface a bead blasting method. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six assembles. Static compression 2% offset yield load ranges was from 327 to 419N. Fatigue loads were determined two levels, 37.5% and 50% of the average load from static compression ultimate load. An assembly of bead blasting treatment only achieved 5 million cycles at 37.5% level in compression bending.

전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 이해도 (The Elementary School Teachers' Understandings about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits)

  • 현동걸;신애경
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제33권2호
    • /
    • pp.335-351
    • /
    • 2014
  • The 96 elementary school teachers' the degrees of understandings about the characteristics of the currents according to the connection methods of batteries in simple electric circuits were investigated. In this study, the concepts on the characteristics of currents according to the connection methods of batteries were divided 'the learned concepts' and 'the differentiated concepts'. The characteristics of the currents in the region of the larger resistance of load than the internal resistance of a battery were called the learned concepts, they are taught in the science curriculum. While the characteristics of the currents in the region of the smaller resistance of load than the internal resistance of a battery were called the differentiated concepts, they are not exposed clearly in the science curriculum. The results obtained in this study are as follows: The average score related to the learned concepts was relatively high, while the degree of the teachers' cognitions of the internal resistance of a battery and the resistance of wires were low. Also the average score related to the differentiated concepts was very low because it seems so new to the elementary school teachers. It strongly suggests that the elementary school teachers did not understand meaningfully the characteristics of the currents related to the connections of batteries on the ground of the cognitions of the internal resistances of batteries and the resistances of loads in simple electric circuits. Hence, they might experience difficulties due to the problems occurred in relation to the connections of batteries in the elementary school science lessons.

PZT계 압전 세라믹 변압기의 감압특성 (Characteristics of Step-Down Transformer in PZT Piezoelectric Ceramics)

  • 김오수;이준형;손정호;남효덕;조상희
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.885-891
    • /
    • 2001
  • Ring/dot-type step-down piezoelectric transformer was manufactured by using Pb[(Mn$\sub$1/3/Sb$\sub$2/3)$\sub$0.05/Zr$\sub$0.475/Ti$\sub$0.475/]O$_3$ ceramics, which have excellent high-power piezoelectric properties. The characteristics of step-down piezoelectric transformer as a function of load resistance at output terminal was examined. Voltage gain was greatly dependent on drive frequency and load resistance, and showed maximum voltage gain at the resonance frequency. The output voltage was linearly increased as the input voltage increased. Voltage gain of the step-down piezoelectric transformer with respect to input voltage was very stable when the load resistance was in the range of 50-500 $\Omega$ .

  • PDF

정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구 (Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load)

  • 송정현;김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

직류전동기의 적응 제어기 설계에 관한 연구 (DESIGN OF ADAPTIVE CONTROLLER OF DC SERVO MOTOR)

  • 장서건;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.25-28
    • /
    • 1987
  • Design procedure of adaptive controller with variable load condition is present and applied to velocity control of small, permanent magnet DC servo motor. The state feedback control scheme is adopted and Recursive Least Squares algorithm is used for parameter estimation. In order to reduce the time consuming. In the procedure of adaptation-gain tuning of state feedback controller, approximate curve fitting technique is applied to the relations between load condition and poles of the system, load condition and feedback gains. With this method, fast adaptation can be accomplished. It is shown that this procedure can be applied not only to variable load condition but also to variation of other system constants, for example variation of resistance and inductance etc.. Simulation results is present for both cases - variable inertia load, variable motor resistance to verify performance improvements. This design procedure produces an adaptive con troller which is feasible for implementation with microprocessor by reducing calculation time.

  • PDF

하중 제어법을 이용한 파이프 줄기초의 현장 인발저항 특성 (Characteristics of Field Uplift Tests of Continuous Greenhouse using the Load Control Method)

  • 임성윤;김명환;김유용;유석철;김석진;임재삼
    • 한국농공학회논문집
    • /
    • 제60권4호
    • /
    • pp.105-111
    • /
    • 2018
  • Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in order to evaluate the uplift resistance of continuous foundation of greenhouse with different depths of the rafters. Institutional inertia anti-disaster standard of greenhouse foundation did not protect the greenhouse structure from the damages caused by strong winds and heavy snow. Therefore, field tests for behavior characteristics of continuous greenhouse foundation were carried out to ensure stable facility cultivation. The field test condition was evaluated using different embedded depth as follows: 30cm, 40cm, 50cm and spacing 50cm, 60cm, 70 cm. As a result of the uplift resistance field tests using the load control method, the minimum uplift resistance was found to be over 90kg and uplift resistance displacement was 9.4mm. Uplift resistance of the continuous greenhouse foundation was in the range of 90-180 kg according to embedded depth and spacing. Using the test condition, there was no constant trend in the uplift resistance.

국내 말뚝재하시험에 대한 지반-말뚝계의 수치해석 (A Numerical Analysis of Soil-Pile Systems for Pile Load Tests at a Korean Site)

  • 오세붕;안태경;최용규
    • 한국해양공학회지
    • /
    • 제13권1호통권31호
    • /
    • pp.94-104
    • /
    • 1999
  • In order to evaluate the performance of axially of laterally loaded piles experimentaly, pile load tests can be carried out at the site Otherwise stress analyses or subgrade reaction analyses can solve the problem. In this study, stress analysis using FLAC code and subgrade reaction analyses using load transfer curves recommended by API(1993) were performed consistently on the basis of a result of site investigations, and the result of analyses was compared with the measured. As a result the behavior of pile heads was analyzed accurately for both axially and laterally loaded tests. Furthermore axially transferred loads were calculated appropriately for the measured and axial loads were transferred mainly mainly by the frictional resistance rather than by the tip resistance. Consequently, it can be commented that both analysis methods of soil-pile systems are applicable at teh objective site and that solutions may be more accurate if material properties from the site investigation are more explicit.

  • PDF

엔진 흡배기 소음원 특성의 특정법에 대한 수치적 연구 (Numerical Investigations of the Experimental Techniques for Measuring the Acoustical Source Parameters of a Simplified Exhaust System)

  • 이정권;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.866-870
    • /
    • 2001
  • Measurement techniques for in-duct acoustic source parameters can be classified into the direct method and the load method, according to whether it utilizes an extra external source or not. It is reported that the load methods yield the negative source resistance and the purpose of this paper is to clarify that the time-varying nature of the source is the main cause of this physically implausible result. For this purpose, the direct and load methods for measuring the source characteristics of a simplified fluid machine are simulated using the time domain numerical analysis. In the numerical simulations, the method of characteristics is employed and the source characteristics are calculated from the resultant data. It is shown that the load method results in negative source resistance for some frequencies, whereas the direct method yields positive values for all frequencies considered. It is found that the result of load method is quite sensitive to the change of cylinder pressure or valve profile in contrast to the direct method.

  • PDF