• 제목/요약/키워드: resin modified glass ionomer

검색결과 87건 처리시간 0.027초

Resin-modified glass ionomer cements의 파절 및 저단결합강도에 관한 실험적 연구 (An Experimental Study on the Fracture and Shear Bonding Strength of Resin-modified Glass lonomer Cements)

  • 김재곤;양철희;안수현;노용관;백병주
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.234-248
    • /
    • 1998
  • The purpose of this study was to compare the fracture and shear bonding strength of resin-modified glass ionomer cements with composite resin and conventional glass ionomer cement Three kinds of restorative materials including a composite resin (Z 100), a conventional glass ionomer cement(Fuji II), and resin- modified glass ionomer cements(Fuji II LC, Vitremer, Dyract and Compoglass) were investigated in this study. For measurement of fracture and shear bonding strength, disk samples of the materials were prepared and cylindrical samples of the materials were bonded the flat enamel and dentin surfaces according to manufactuer's instructions. All specimen were determinated by using an Instron testing machine with a crosshead speed of 1 mm/min. Then, each treated enamel and dentin surface was observed by SEM. The following results were obtained. 1. The bi-axial flexural strength of Z 100 was highest, and Fuji n LC, Vitremer, Dyract and Compoglass were significantly higher than Fuji n (P<0.05). 2. The shear bonding strength of Z 100 on the enamel and dentin surface was higher than other experimental groups except Fuji II LC(P<0.05). Fuji II LC was significantly higher than Fuji II (P<0.05), but in the case of Vitremer, Dyract and Compoglass were similar to Fuji II (P>0.05). 3. The shear bonding strength of Z 100 and Fuji II LC on the enamel surface were highly increased as compared with dentin surface (P<0.05), but in the case of Fuji II, Vitremer, Dyract and Compoglass were not different between enamel and dentin(P>0.05). 4. In the Z 100 and Fuji II LC, obvious etched enamel surface and exposed dentinal tubules according to remove of smear layer and smear plug were observed.

  • PDF

Effects of Hybrid Coat on shear bond strength of five cements: an in-vitro study

  • Guo, Yue;Zhou, Hou-De;Feng, Yun-Zhi
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.447-452
    • /
    • 2017
  • PURPOSE. To evaluate the sealing performance of Hybrid Coat and its influence on the shear bond strength of five dentin surface cements. MATERIALS AND METHODS. Six premolars were pretreated to expose the dentin surface prior to the application of Hybrid Coat. The microscopic characteristics of the dentinal surfaces were examined with scanning electron microscopy (SEM). Then, 40 premolars were sectioned longitudinally, and 80 semi-sections were divided into a control group (untreated) and a study group (treated by Hybrid Coat). Alloy restoration was bonded to the teeth specimen using five different cements. Shear bond strength was measured by the universal testing machine. The fracture patterns and the adhesive interface were observed using a stereomicroscope. RESULTS. SEM revealed that the lumens of dentinal tubules were completely occluded by Hybrid Coat. The Hybrid Coat significantly improved the shear bond strength of resin-modified glass ionomer cement (RMGIC) and resin cement (RC) but weakened the performance of zinc phosphate cement (ZPC), zinc polycarboxylate cement (ZPCC) and glass ionomer cement (GIC). CONCLUSION. Hybrid Coat is an effective dentinal tubule sealant, and therefore its combined use with resin or resin-modified glass ionomer cements can be applied for the prostheses attachment purpose.

상아질 결합제가 컴포머의 불소유리에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF DENTIN ADHESIVE TO FLUORIDE RELEASE OF COMPOMER)

  • 윤여상;김종수;권순원;김용기
    • 대한소아치과학회지
    • /
    • 제28권2호
    • /
    • pp.228-237
    • /
    • 2001
  • 본 연구의 목적은 와동 충전시 충전재와 치질 사이에 개재되는 상아질 결합제가, 수복물에서 유리되는 불소가 와동 벽으로 침투하는 과정에 어떠한 영향을 주는지를 조사함이었고, 부가적으로 레진 강화형-글라스 아이오노머 시멘트의 접착에도 상아질 결합제를 도포 하는것이 치질과의 결합력을 강화시킬 수 있는지에 대해 평가하고자 하였다. Fuji II $LC^{(R)}$와 Dyract $AP^{(R)}$를 선정하여 상아질 결합제의 도포 여부에 따른 불소 유리량 측정과 전단 결합 강도를 비교분석하였으며, 치질 내로의 불소 침투 양상은 교환 시기에 있는 제2유구치에 Fuji II $LC^{(R)}$와 Dyract $AP^{(R)}$를 충전하고 3주내에 발거하여 EPMA로 분석하였다. 상아질 결합제는 불소 유리량을 현저하게 감소시키는 것으로 나타났으며(p<0.05) Fuji II $LC^{(R)}$의 경우 상아질 결합제의 도포가 결합강도를 증가시키지 못하였다. EPMA 분석결과 상아질 결합제는 충전재로부터 유리되어 나오는 불소가 치질 내로 확산되는 것을 방해하는 것으로 확인되었다.

  • PDF

구치부 복합레진 수복을 위한 와동 이장용 재료의 방사선투과성에 관한 연구 (A Study on the Radiopacity of Cavity Lining Materials for Posterior Composite Resin Restoration)

  • 문주훈;최의환
    • Imaging Science in Dentistry
    • /
    • 제30권4호
    • /
    • pp.243-248
    • /
    • 2000
  • Purpose: The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Plowable resin) for posterior composite resin restoration. Material & Methods: Resin-modified glass ionomer cement (Fuji II LC, Vitrebond/sup TM/), Compomers (Dyract /sup (R)/ Compoglass, F2,000, Dyract/sup (R)/ flow Compoglass Flow) and Flowable resins (Tetric/sup (R)/ flow, Aeliteflo/sup TM/ Revolution/sup TM/) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtainded from conventional radiograph and NIH image program. Results: All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract, Compoglass, F2,000, Dyract flow, Compoglass Flow) and Vitrebond/sup TM/, Tetric/sup (R)/ flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution/sup TM/ were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric/sup (R)/ flow were greater than those of Revolution/sup TM/, Aeliteflo/sup TM/ or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Conclusion: Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  • PDF

Current aspects and prospects of glass ionomer cements for clinical dentistry

  • Park, Eun Young;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • 제37권3호
    • /
    • pp.169-178
    • /
    • 2020
  • Glass ionomer cement (GIC) is a tailor-made material that is used as a filling material in dentistry. GIC is cured by an acid-base reaction consisting of a glass filler and ionic polymers. When the glass filler and ionic polymers are mixed, ionic bonds of the material itself are formed. In addition, the extra polymer anion reacts with calcium in enamel or dentin to increase adhesion to the tooth tissue. GICs are widely used as adhesives for artificial crowns or orthodontic brackets, and are also used as tooth repair material, cavity liner, and filling materials. In this review, the current status of GIC research and development and its prospects for the future have been discussed in detail.

연마시 여러 가지 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VAR10US RESTORATIVE MATERIALS AND BASES DURING POLISHING PROCEDURE)

  • 백병주;이두철;김미라;김재곤
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.410-418
    • /
    • 2000
  • 치아수복시 마무리 과정에서의 연마는 수복물의 수명 및 심미성을 결정하는 중요한 과정으로서 연마시 마찰열의 발생으로 인하여 치수에 위해작용을 줄 수 있으므로 주의를 하여야 한다. 여러 가지 수복 재료를 연마하는 동안 치수내에서 발생하는 열의 변화를 수복물 종류, 이장재 종류, 잔존 상아질의 두께, 연마 시간의 차이에 따라 조사하고자 발치된 구치에 수복물을 충전한 후 aluminum-oxide coated disc를 이용하여 연마하는 과정에서 thermocouple을 이용하여 치수내 온도값을 측정하였으며, 이에 대한 통계적 분석을 시행하여 다음과 같은 결과를 얻었다. 모든 경우에서 연마 시간이 증가함에 따라 치수내 온도가 증가하였으며, 아말감 연마시 다른 수복 재료에 비해 큰 온도 증가치를 보였으나 composite resin, glass ionomer cement, 그리고 compomer에서는 연마에 따른 온도 변화차가 관찰되지 않았다. 아말감 하방에 이장재를 사용한 경우에 이장재를 사용하지 않았을 경우에 비해 온도 증가량이 적었으며, 다른 수복재에서는 이장재 사용여부에 따른 온도 증가량의 차이는 존재하지 않았다. 본 실험에서 사용된 이장재 중 glass ionomer cement와 zinc phosphate cement에 비해 zinc oxide eugenol cement의 열 차단 효과가 가장 작았다. 수복물에 간헐적인 연마를 시행한 경우, 지속적인 연마를 시행한 경우에 비해 온도 증가량이 작았으며, 아말감 하방의 잔존 상아질의 두께가 감소하면 온도 증가량이 더 커졌으나, 다른 세 종류의 수복재에서는 잔존 상아질의 두께에 따른 차이가 발생하지 않았다.

  • PDF

레진강화형 글라스아이오노머의 2 축 굽힘강도 (BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS)

  • 이용근;임미경;구대회;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF

Resin-Modified Glass-Ionomer와 Compomer의 경화 반응 특성의 비교에 관한 연구 (A COMPARISON OF THE SETTING CHARACTERISTICS BETWEEN RESIN-MODIFIED GLASS-IONOMERS AND COMPOMERS)

  • 고용준;유현미;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.123-132
    • /
    • 2000
  • To overcome problems of conventional glass ionomers, resin components have been added to glass ionomers. On a continuum between glass ionomers and composites are a variety of blends, employing different proportions of acid-base and free radical reactions to bring about cure. Popular groups defined between the ends are resin-modified glass-ionomers(RMGIs), polyacid-modified composite resins(Compomers) and ionomer modified resins. These groups show different clinical properties, and in selecting these materials for a restoration, one should sufficiently understand these different setting properties. In this study, some difference in the setting characteristics of different groups of hybrid ionomers were examined. Two RMGIs (Fuji2 LC,GC / Vitremer, 3M), three Compomers (Dyract AP, Dentsply / F2000, 3M / Elan, Kerr) were involved in this study. The identification of the setting characteristics of different groups was achieved by a two-stage study. First, thermal analysis was performed by a differential scanning calorimeter, and then the hardness of each group at different depth and time were measured by a micro-hardness tester. Thermal analysis was performed to identify the inorganic filler content and to record the heat change during setting process. The setting process was progressed for each material by chemical set mode and light-cured mode. In the hardness test, samples of materials were prepared with a 6mm-diameter metal ring, and the hardness was measured at the top, and 1mm, 2.5mm, 4mm below at just after a 40 second-cure, and after 10 minutes, 24 hours, and 7 days. Statistical analysis was performed by Mann-Whitney rank sum test to assess significant differences between set modes and types of materials, and by ANOVA and T-test to evaluate the statistical meanings of data at different times and depths of each materials. Followings are findings and conclusions derived from this study. Thermal analysis; 1. Compomers show no evidence of chemical setting while RMGIs exhibit heat output during the process of chemical setting. 2. Heat of cure of RMGIs exceed Compomers. 3. The net heat output of RMGIs through light-cured mode is higher than through chemically set mode. Hardness test; 1. Initial hardness of RMGIs immediately after light cure is relatively low, but the hardness increases as time goes by. On the contrary, Comomers do not show evident increase of the hardness following time. 2. Compomers show a marked decrease of setting degree as the depth of the material increases. In RMGIs, the setting degree at different depths does not significantly differ.

  • PDF

와동형태가 5급 와동 수복물의 변연누출에 미치는 영향 (THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION)

  • 박정길;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

미세전산화 단층 촬영을 이용한 글라스 아이오노머 수복의 인접면 재광화 효과에 대한 연구 (REMINERALIZATION EFFECTS OF GLASS IONOMER RESTORATIONS ON ADJACENT INTERPOXIMAL-A MICROTOMOGRAPHIC STUDY)

  • 이혁상;이상대;김정욱;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제31권3호
    • /
    • pp.474-480
    • /
    • 2004
  • 이 연구의 목적은 Compomer, high filled Glass Ionomer Cement, Resin Modified Glass Ionomer Cement, 그리고 불소를 방출하지 않는 복합 레진(대조군)의 인접면 초기 우식 병변에 있어서의 재광화 효과를 미세전산화 단층촬영 (SkyScan-1072, Skyscan b.v.b.a., Belgium)과 3차원 영상 분석기 ($Vworks^{TM}$, Cybermed, Korea)를 이 용하여 병소의 미세 밀도의 변화량을 측정, 비교하여 평가하는 것이다. 치아 시편과 glass ionomer cement 수복물로 치아의 인접면을 재현하여 인공타액에 담근 후 1개월 2개월 후에 미세전산화 단층 촬영을 시행한 후 3차원 영상 분석 프로그램을 사용하여 인공 우식부위의 미세 밀도를 측정하여 그 변화량을 분석하여 재광화 정도를 평가하였다. 사용된 재료는 1군은 Compomer인 F2000(3M ESPE, St. Paul, Minn., USA), 2군은 high filled GIC인 Fuji IX GP (GC Corp., Tokyo, Japan), 3군은 Resin Modified Glass Ionomer Cement인 Vitremer (3M ESPE, St. Paul, Minn., USA), 그리고 4군은 복합 레진인 Z250(3M ESPE, St. Paul, Minn., USA)이었다. 위의 과정을 거쳐 얻어진 자료를 토대로 분석한 결과 다음과 같은 결론을 얻었다. 1) 세 종류의 글라스 아이오노머 수복재는 첫째 달과 둘째 달에서 모두 복합 레진과 비교하여 밀도가 유의차 있게 증가하였다. 2) 1군, 2군, 3군 각각은 밀도의 증가가 서로에 대하여 통계적으로 유의차가 없었다. 3) 각 재료의 재광화 효과를 비교한 결과 모든 글라스 아이오노머 수복재는 첫째 달과 둘째 달 사이에 통계적인 유의 차를 보였으며 복합 레진은 유의차가 없었다.

  • PDF