In this study, the variation of the shrinkage in the thickness direction of the molded parts according to the gate size of the polymer core fabricated through the 3D printer using the SLS method was studied. The polymer cores are laser sintered and the powder material is nylon base PA2200. The polymer cores have lower heat transfer rate and rigidity than the metal core due to the characteristics of the material. Therefore, the injection molding test conditions are set to minimize the deformation of the core during the injection process. The resin used in the injection molding test is a PP material. The packing condition was set to 80, 90 and 100% of the maximum injection pressure for each gate size. The runner diameter used was ∅3mm, and the gates were fabricated in semicircle shapes with cross sections 1, 2, and 3 ㎟, respectively. Thickness measurement was performed for 10 points at 2.5 mm intervals from the point 2.5 mm away from the gate, and the shrinkage to thickness was measured for each point. The shrinkage rate according to the gate size tends to decrease as the cross-sectional area decreases as the maximum injection pressure increases. The average thickness shrinkage rate was close to 0% when the packing pressure was 90% for the gate area of 1mm2. When the holding pressure was set to 100%, the shrinkage was found to decrease by 3% from the standard dimension due to the over-packing phenomenon. Therefore, the smaller the gate, the more closely the molded dimensions can be molded due to the high pressure generation. It was confirmed that precise packing process control is necessary because over-packing phenomenon may occur.
Ag 200 ppm과 총유량 120 l/h의 기준으로 이온 교환 섬유 시스템을 제작하였다. 이 시스템은 이온교환 섬유로서 강염기성인 FIVAN A-6을 이용하였고, 이온교환 섬유의 교환이 용이하고 고정틀이 필요 없도록 고안된 이중관 형 이온 교환 섬유조로 구성되어있다. 이 시스템의 이온교환섬유의 Ag에 대한 이온교환 용량은 4.6 meq/g 이었으며, 공정조건별로는 다음과 같은 결과를 얻었다. 흡착공정의 경우 유속의 영향을 확인한 후 40~90 l/h의 범위에서 운전하였으며, pH 7~12 범위에서는 Ag의 착이온 형성에 대한 pH의 영향이 없는 것으로 나타났다. 역세공정의 경우 60~120 l/h의 범위에서 Ag 회수율 실험을 수행하였으며, 역세용 화학물질로는 NaOH, $NH_4Cl$, NaCl을 이용하여 비교실험을 하였고, 역세 화학물질이 고농도 일수록 탈착시간은 짧아지지만 몰당 탈착 효율은 저하되는 경향이었으므로 탈착시간과 농도의 균형을 잘 맞추어 운전해야 경제적 운전이 될 수 있음을 확인하였다. 강염기성 음이온 섬유인 FIVAN A-6와 이중관형 이온교환 섬유조를 이용하여 Ag 흡착율은 99.5% 이상, 총 Ag회수율은 96% 이상의 결과를 얻을 수 있었으며 상용화 가능함을 확인할 수 있었다.
o-Nitrotoluene is used to synthesize artificial dyes and raw materials of urethane resin. In this study, we have carried out in vitro genetic toxicity tests and microarray analysis to understand the underlying mechanisms and the mode of action of toxicity of onitrotoluene. TA1535 and TA98 cells were treated with o-nitrotoluene to test its toxicity by basic genetic toxicity test. Ames and two new in vitro micronucleus and COMET assays were applied using CHO cells and L5178Y cells, respectively. In addition, microarray analysis of differentially expressed genes in L5178Y cells in response to o-nitrotoluene was analyzed using Affymatrix genechip. The result of Ames test was that o-nitrotoluene treatment did not increase the mutations both in base substitution strain TA1535 and in frame shift TA98. o-Nitrotoluene has not increased micronuclei in CHO cells. But onitrotoluene increased DNA damage in L5178Y cell. Two-hundred two genes were initially selected as differentially expressed genes in response to o-nitrotoluene by microarray analysis and forty four genes among them were over 2 times of log fold changed. These forty four genes could be candidate biomarkers of genetic toxic action of o-nitrotoluene related to induction of mutation and/or induction of micronuclei and DNA damage. Further confirmation of these candidate markers related to the DNA damage will be useful to understand the detailed mechanism of action of o-nitrotoluene.
본 연구에서는 sodium 2-diazo-1-naphthoquinone-5-sulfonate를 chlorination하여 2-diazo-naphthoquinone-5-sulfonyl chloride(NQD-Cl)를 합성하였다. NQD-Cl을 여러 종류의 hydroxybenzophenone 유도체와 esterification하여 hydroxy group이 2-diazo-naphthoquinone-5-sulfonyl(NQD) group으로 치환된 여러 종류의 1,2-naphthoquinone-(1,2)-diazide-5-sulfonic acid esters(NQD0ester) 유도체를 합성하였다. NQD-ester 유도체의 용해도를 증가시키기 위해 methoxy group이 도입된 유도체와 이와 비교를 위해 hydroxy group만을 가지는 benzophenone 유도체를 사용하여 비교하였다. 각각의 NQD-ester 유도체의 용해특성을 조사하였으며, novolac수지와 혼용(formulation)하여 감광액을 제조하여 알루미늄판에 도포, 건조하여 PS판을 제조하였다. PS판의 감광특성과 광퇴색도와 화상형성에 적합한 노광시간을 조사하였으며, 상대감도를 gray scale(GS)법으로 조사하였다. 치환된 NQD group 의 수에 따라 GS법에 의한 상대감도가 다르게 나타나는 것을 알 수 있었다. Methoxy group이 도입된 NQD-ester유도체는 좋은 용해특성을 보여주었으며 시판되는 PS판과 동일한 노광조건에서 비교해 본 결과 보다 우수한 감도를 보였다.
안성 청룡사삼층석탑의 구성암석은 대부분 편마상 복운모 화강암과 세립질 화강암으로 이루어져 있다. 이 석탑은 거의 전면에 걸쳐 나타나는 부재의 균열과 결실이 탑의 구조안정성을 위협한다. 또한 표면의 무기오염물과 다양한 서식형태를 갖는 생물침해는 석재표면의 손상을 가중시키고 있다. 따라서 이 연구에서는 석탑에 대한 종합적인 비파괴훼손도 진단을 수행하고 이를 근거로 풍화를 저감시키기 위해 최소한의 보존처리를 수행하였다. 보존처리에서는 석탑의 전면에 걸쳐 자생하는 지의류 및 생물오염물을 건식 및 습식 세정하였으며, 과거 이 석탑의 보수에 사용되었던 노화된 콘크리트를 제거하고 합성수지를 이용하여 복원하였다. 부재사이에 삽입된 부식된 철편은 티타늄 강철 합금으로 교체하였으며, 모든 공정이 완료된 후에 석질 강화처리를 실시하였다. 또한 석탑의 지반과 주위환경을 보강하고 정비하였으며 관람객에 의한 손상을 제어하기 위한 보호시설을 설치하였다.
본 연구에서는 열 안정성 염 제거장치가 추가된 아민 재생 공정을 모사하고, 폐수 량, 열 안정성 염 제거 량, MDEA(methyl diethanolamine) 손실량을 고려한 최적 운전조건 도출 전략을 제시하였다. 산성 가스를 흡수 및 탈거하는 아민 재생공정에서 열 안정성 염은 공정 장비 및 아민 용액의 흡수 효율을 저해한다. 열 안정성 염 제거 방법 중 하나인 이온교환수지법은 NaOH와 같은 강 염기성 용액을 사용하여 중화반응을 통해 염을 제거시키는 방법이다. 공정 모델링 과정에서 산성 가스의 탈거 과정은 Radfrac 모델을 사용했고, 반응의 평형상수는 Gibbs 자유에너지를 사용하여 계산하였다. 탈거된 아민 용액의 일부는 열 안정성 염 제거 장치로 들어가게 되고, 제거 장치는 중화반응을 이용한 Rstoic 모델을 사용하였다. 실제 운전데이터와 시뮬레이션 결과를 비교하여 검증하였고, 제거 장치로 들어가는 질량 유량을 조절하여 사례연구를 하고 최적 운전 조건을 제시하였다.
목적: 본 연구의 목적은 air-blasting particle size를 달리하고 분사 압력과 시간을 통상보다 크게 증가시켜 표면에 큰 손상을 유발한 군을 상대적으로 작은 손상을 유발한 군과 비교하여 파절 저항과 접착 강도 차이를 보이는지 평가하는 데 있다. 연구 재료 및 방법: 지르코니아($LAVA^{TM}$) 디스크 표면에 각각 $30{\mu}m$- particle size (Cojet) 2.8 bar 15초, $110{\mu}m$- (Rocatec) 2.8 bar 15초, $110{\mu}m$- (Rocatec) 3.8 bar 30초로 조건을 달리하여 표면처리 후 각각 이축 굽힘하중 강도 실험과 접착 파절 하중 실험을 실행하였다. 접착은 상아질 유사 베이스에 $200{\mu}m$ 두께의 레진시멘트로 시행하여 인장력을 극대화하였으며 음향방출(AE) 센서로 실패하중을 검출하였다. 결과: 이축 굽힘하중 강도, 접착 파절하중은 세 군간 서로 유의성 있는 차이를 보이지 않았다(P > 0.05). 접착 시편의 균열은 대부분 radial crack이었다. 결론: 정하중 평가의 한계 내에서, air-blasting particle size와 압력에 의한 표면 손상은 크지 않았으며, 접착 파절하중 평가는 표면 손상과 접착 강도를 동시에 평가할 수 있는 방법이라 여겨진다.
von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
The Journal of Advanced Prosthodontics
/
제12권2호
/
pp.100-106
/
2020
PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.
폴리페닐렌에테르[PPE, poly(phenylene ether)]를 기저수지로 사용하고, 가교제로 N,N'-m-phenylene-dimaleimide(PDMI), 난연제로 decabromodiphenylethane을 첨가하여 고분자 기판을 제작하였으며, 가교제와 난연제가 기판소재의 유전특성 등 물리적 특성에 미치는 영향을 고찰하였다. 개시제의 유무에 따른 PDMI의 열경화 특성을 DSC를 이용하여 분석하였으며, 이를 바탕으로 PPE-PDMI 테스트 조성을 설계하였다. 복합물 시트를 필름 코터로 성형한 후, 진공가압적층하여 테스트 기판을 제작하고, FDMI와 난연제의 함량에 따른 유전율, 유전손실, peel 강도, 납 내열성 및 난연성을 평가하였다. 유전율과 유전손실은 PDMI와 난연제의 함량에 따라 대체로 증가하는 경향을 나타내었으나, 납 내열성과 난연성은 개선된 결과를 나타내었다. Peel 강도는 PDMI가 10 wt% 이상 첨가되면 1 kN/m 이상의 높은 값을 나타내었지만, 난연제의 첨가량에 따라서는 소폭 감소하는 경향을 보였다. Gel content 측정결과로부터, PPE-PDMI의 반응 메카니즘은 semi-IPN 구조의 형성보다는 PPE와 PDMI의 crosslinking에 의한 망상구조 형성에 더 가까운 것으로 판단되었다. 최종적으로 1 GHz에서 유전율이 2.52$\sim$2.65, 유전손실이 0.002 미만으로 작은 고주파 대역용 고분자 복합체 기판소재를 얻을 수 있었다.
Purpose: The aim of this study was to evaluate accuracy of three type complete mandibular denture of before and after polymerization. Methods: Mandibular edentulous model was selected as the master model. 15 study models were made by Type IV stone. Wax complete mandibular dentures were produced by the denture base and artificial teeth. Before and after curing, STL files were obtained using a blue scanner. By superimposing the digitized complete mandibular denture data(after curing) with the CAD-reference(before curing) three-dimensionally, visual fit-discrepancies were drawn by calculating the root mean square (RMS) and visualized on a color-difference map. Each calculated RMS-value was statistically analyzed by 1-way analysis of variance(ANOVA) (${\alpha}=.05$). Results: Mean(SD) RMS-values was OM group $88.98(6.10){\mu}m$, BM group $82.35(13.46){\mu}m$, BDM group $77.83(9.46){\mu}m$. The results of the 1-way ANOVA showed no statistically significant differences in the RMS values of the Three groups for the material (P > .241). Conclusion : Deformation of artificial teeth position was observed in all groups after resin polymerization. But the values, all group were within the clinically acceptable range. The values of BDM group showed the least deformation than the other two groups.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.